AUTOMATION
CONTROLS

Search
Discontinued
Products



DS Power Relays

PC board sockets

Dimensions

Selector chart

Relay type Socket
1 Form A 1 Form A,
1 Form A 1 Form B,
2 Form A
Single side stable,
1 coil latching
2 coil latching Single side stable,
1 coil latching
2 coil latching
1 Form A Single side stable
1 coil latching - -
2 coil latching - -
1 Form A
1 Form B
Single side stable - -
1 coil latching - - -
2 coil latching - - -
2 Form A Single side stable - -
1 coil latching - - -
2 coil latching - - -

Return to top

Types

Product name Single side stable,
1 coil latching
2 coil latching Standard packing
Type No. Part No. Type No. Part No. Inner carton Outer carton
1 Form A DSP1a-PS AGP2800 DSP1a-PSL2 AGP2802 50 pcs. 500 pcs.
1 Form A,
1 Form A 1 Form B,
2 Form A
DSP2a-PS AGP2820 DSP2a-PSL2 AGP2822

Return to top

Rating

Item Specifications
Dielectric strength
(initial)
Each between terminal: 3,000 Vrms for 1 min
(detection current: 10 mA)
(Except for the portion between coil terminals, DSP1a-PSL2 and DSP2a-PSL2 applicable)
Insulation resistance
(initial)
Each between terminal: Min. 1,000 MΩ
(at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Maximum carrying
current
8 A (DSP1a-PS, DSP1a-PSL2)
5 A (DSP2a-PS, DSP2a-PSL2)
Conditions for usage,
transport and storage
Ambient temperature: -40 to +65°C
Humidity: 5 to 85% RH (Avoid icing and condensation)

Return to top

Handling

Mounting method of relay

1) Match the direction of relay and socket.

2) Both ends of relays are fixed so tightly that the socket hooks on the top surface of relays.

Removing method of relay

1) Remove the relay, applying force in the direction as shown in the figure.

2) In case there is not enough space for finger to pick relay up, use screw drivers in the way as shown in the figure.

3) Exercise care when removing relays. If greater than necessary force is applied at the socket hooks, deformation may alter the dimensions so that the hook will no longer catch, and other damage may also occur.

Return to top

Guidelines for usage

• Do not remove or insert relays when they are energized.
• Do not install other brands of relays into these sockets.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)