Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > Power Relays (Over 2A) Lineup > DY Relays > Rating/Performance
|
Rated coil voltage |
Operate voltage* (at 20°C) |
Release voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
3 V DC | Max. 70% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
66.6 mA | 45 Ω | 200 mW | 130% V of rated coil voltage |
5 V DC | 40 mA | 125 Ω | ||||
6 V DC | 33.3 mA | 180 Ω | ||||
9 V DC | 22.2 mA | 405 Ω | ||||
12 V DC | 16.6 mA | 720 Ω | ||||
24 V DC | 8.3 mA | 2,880 Ω |
* | square, pulse drive |
---|
Rated coil voltage |
Set voltage* (at 20°C) |
Reset voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
|||
---|---|---|---|---|---|---|---|---|---|
Set coil |
Reset coil |
Set coil |
Reset coil |
Set coil |
Reset coil |
||||
3 V DC | Max. 70% V of rated coil voltage (Initial) |
Max. 70% V of rated coil voltage (Initial) |
66.6 mA | 66.6 mA | 45 Ω | 45 Ω | 200 mW | 200 mW | 130% V of rated coil voltage |
5 V DC | 40 mA | 40 mA | 125 Ω | 125 Ω | |||||
6 V DC | 33.3 mA | 33.3 mA | 180 Ω | 180 Ω | |||||
9 V DC | 22.2 mA | 22.2 mA | 405 Ω | 405 Ω | |||||
12 V DC | 16.6 mA | 16.6 mA | 720 Ω | 720 Ω | |||||
24 V DC | 8.3 mA | 8.3 mA | 2,880 Ω | 2,880 Ω |
* | square, pulse drive |
---|
Item | Specifications | ||
---|---|---|---|
Contact data | Contact arrangement | 1 Form A | 1 Form A 1 Form B |
Contact resistance (Initial) | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | ||
Contact material | Au-flashed AgSnO2 type | ||
Contact rating (resistive) | 10 A 250 V AC, 10 A 30 V DC | 8 A 250 V AC, 8 A 30 V DC | |
Max. switching power (resistive) |
2,500 VA, 300 W | 2,000 VA, 240 W | |
Max. switching voltage | 250 V AC, 125 V DC (0.2 A) | ||
Max. switching current | 10 A | 8 A | |
Min. switching load (reference value)*1 |
10 mA 5 V DC | ||
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | ||
Dielectric strength (Initial) | Between open contacts |
1,000 Vrms for 1 min (detection current: 10 mA) | |
Between contact sets |
- | 4,000 Vrms for 1 min | |
Between contact and coil |
4,000 Vrms for 1 min (detection current: 10 mA) | ||
Surge withstand voltage (Initial)*2 | Between contact and coil |
10,000 V | |
Time characteristics (initial) |
Operate (Set) time | Max. 10 ms (Max. 10 ms) at rated coil voltage (at 20°C, without bounce) | |
Release (Reset) time | Max. 8 ms (Max. 10 ms) at rated coil voltage (at 20°C, without bounce, without diode) | ||
Shock resistance |
Functional | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) | |
Destructive | 980 m/s2 (half-sine shock pulse: 6 ms) | ||
Vibration resistance |
Functional | 10 to 55 Hz (at double amplitude of 1.5 mm) (detection time: 10 μs) | |
Destructive | 10 to 55 Hz (at double amplitude of 3 mm) | ||
Expected life | Mechanical life | Min. 50 x 106 ope. (switching frequency: at 300 times/min) | |
Conditions | Conditions for usage, transport and storage *3 |
Ambient temperature: –40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
|
Unit weight | Approx. 6 g |
*1 | This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. |
---|---|
*2 | Wave is standard shock voltage of ±1.2 x 50 μs according to JEC-212-1981 |
*3 | For ambient temperature, please read "GUIDELINES FOR RELAY USAGE". |
Conditions: Resistive load, Switching frequency at 20 times/min
Type | Switching capacity | Number of operations |
---|---|---|
1 Form A | 10 A 250 V AC 10 A 30 V DC |
Min. 100 x 103 ope. |
1 Form A 1 Form B | 8 A 250 V AC 8 A 30 V DC |
Min. 100 x 103 ope. |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)