Coil data

  • Operating characteristics such as 'Operate voltage' and 'Release voltage' are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ±5% of rated coil voltage.
  • 'Initial' means the condition of products at the time of delivery.
Contact
arrangement
Rated coil
voltage
Operate voltage*1
(at 20°C)
Release voltage
(at 20°C)
Rated operating
current
(±10% at 20°C)
Coil resistance
(±10% at 20°C)
Rated operating
power
Max. allowable voltage
1 Form A 5 V DC Max. 75% V of rated coil voltage
(initial)
Min. 5% V of rated coil voltage
(initial)
40 mA 125 Ω 200 mW 130% of rated coil voltage (at 85°C)*2
180% of rated coil voltage (at 20°C)
6 V DC 33.3 mA 180 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
18 V DC 11.1 mA 1,620 Ω
24 V DC 8.3 mA 2,880 Ω
1 Form C 5 V DC Max. 75% V of rated coil voltage
(initial)
Min. 5% V of rated coil voltage
(initial)
80 mA 62.5 Ω 400 mW 110% of rated coil voltage (at 85°C)*2
150% of rated coil voltage (at 20°C)
6 V DC 66.7 mA 90 Ω
9 V DC 44.4 mA 202.5 Ω
12 V DC 33.3 mA 360 Ω
18 V DC 22.2 mA 810 Ω
24 V DC 16.7 mA 1,440 Ω
*1Square, pulse drive.
*2When using relays in a high ambient temperature, consider the operate voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C with 20°C as a reference)and use a coil impressed voltage that is within the maximum applied voltage range.

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form A 1 Form C
Contact resistance (initial) Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material AgNi type
Contact rating
(resistive)
5 A 30 V DC,
10 A 125 V AC,
5 A 250 V AC
Form A contact : 10 A 125 V AC,
5 A 250 V AC,
5 A 30 V DC
Form B contact : 3 A 125 V AC,
2 A 250 V AC,
1 A 30 V DC
Max. switching power
(resistive)
1,250 VA, 150 W Form A contact : 1,250 VA, 150 W
Form B contact : 500 VA, 30 W
Max. switching voltage 250 V AC, 30 V DC
Max. switching current 10 A (125 V AC),
5 A (30 V DC)
Form A contact : 10 A (125 V AC),
5 A (30 V DC)
Form B contact : 3 A (125 V AC),
1 A (30 V DC)
Min. switching load
(reference value)*1
100 mA 5 V DC
Insulation resistance(initial) Min. 1,000 MΩ
(at 500 V DC, Measured portion is the same as the case of dielectric strength)
Dielectric strength
(initial)
Between open contacts 1,000 Vrms for 1 min.
(detection current : 10 mA)
750 Vrms for 1 min.
(detection current : 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (detection current: 10 mA)
Surge withstand voltage (initial)*2 Between contact and coil 8,000 V
Time characteristics
(initial)
Operate time Max. 20 ms (at rated coil voltage, at 20°C, without bounce)
Release time Max. 20 ms (at rated coil voltage, at 20°C, without bounce,with diode)
Shock resistance Functional 294 m/s²
(half-sine pulse : 11 ms,
detection time : 10 µs)
196 m/s²
(half-sine pulse : 11 ms,
detection time : 10 µs)
Destructive 980 m/s² (half-sine shock pulse : 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of 1.6 mm detection time : 10 µs)
Destructive 10 to 55 Hz (at double amplitude of 2 mm)
Expected life Mechanical life Min. 10 x 106 ope. (at 180 times/min)
Conditions Conditions for usage,
transport and storage*3
Ambient temperature: – 40 to + 85°C *4
Humidity : 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 7 g
*Note : Specifications will vary with foreign standards certification ratings.
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Wave is standard shock voltage of ±1.2 x 50 µs according to JEC-212-1981
*3For ambient temperature please read “GUIDELINES FOR RELAY USAGE”.
*4When using relays in a high ambient temperature, consider the operate voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C with 20°C as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.

Return to top

Expected electrical life

Condition: Resistive load, at 20°C, at 20 times/min, with diode

Type Switching capacity Number of operations
1 Form A 5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
100 x 103 ope.
50 x 103 ope.
50 x 103 ope.
1 Form C Form A contact 5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
100 x 103 ope.
50 x 103 ope.
50 x 103 ope.
Form B contact 3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
200 x 103 ope.
200 x 103 ope.
100 x 103 ope.

Return to top

Insulation Characteristic (IEC61810-1)

Item Characteristic
Clearance / Creepage distance (IEC61810-1)* Min. 4.0 mm / 4.0 mm
Category of protection (IEC61810-1) RTIII
Tracking resistance (IEC60112) PTI 175
Insulation material group III a
Over voltage category III
Rated voltage 250 V
Pollution degree 2
Type of insulation (Between contact and coil) Basic insulation
Type of insulation (Between open contact) Micro Disconnection

Note) Actual value.
* For Min. 5.5/5.5 mm (Reinforced insulation) , please contact our sales representative for details.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)