AUTOMATION
CONTROLS

Search
Discontinued
Products



SF Relay Slim type

Coil data

Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions or ambient temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.

"Initial" means the condition of products at the time of delivery.

Contact arrangement Rated coil voltage Operate
voltage*
(at 20°C)
Release
voltage*
(at 20°C)
Rated
operating
current
[±10%]
(at 20°C)
Coil
resistance
[±10%]
(at 20°C)
Rated
operating
power
Max.
allowable
voltage
(at 20°C)
4 poles 2 Form A
2 Form B
12 V DC Max. 75% V of rated coil voltage (Initial) Min. 10% V of rated coil voltage (Initial) 30 mA 400 Ω Approx.
360 mW
110% V of rated coil voltage
18 V DC 20 mA 900 Ω
21 V DC 17.1 mA 1,225 Ω
24 V DC 15 mA 1,600 Ω
48 V DC 7.5 mA 6,400 Ω
3 Form A
1 Form B
12 V DC 30 mA 400 Ω
18 V DC 20 mA 900 Ω
21 V DC 17.1 mA 1,225 Ω
24 V DC 15 mA 1,600 Ω
48 V DC 7.5 mA 6,400 Ω
6 poles 4 Form A
2 Form B
12 V DC 41.7 mA 288 Ω Approx.
500 mW
18 V DC 27.8 mA 648 Ω
21 V DC 23.8 mA 882 Ω
24 V DC 20.8 mA 1,152 Ω
48 V DC 10.4 mA 4,608 Ω
5 Form A
1 Form B
12 V DC 41.7 mA 288 Ω
18 V DC 27.8 mA 648 Ω
21 V DC 23.8 mA 882 Ω
24 V DC 20.8 mA 1,152 Ω
48 V DC 10.4 mA 4,608 Ω
3 Form A
3 Form B
12 V DC 41.7 mA 288 Ω
18 V DC 27.8 mA 648 Ω
21 V DC 23.8 mA 882 Ω
24 V DC 20.8 mA 1,152 Ω
48 V DC 10.4 mA 4,608 Ω

Note) For with LED indication, the rated operating current will increase by approximately 2 mA due to the LED display.

*square, pulse drive (JIS C 5442)

Return to top

Specifications

Item Characteristics
4 poles 6 poles
Contact data Contact arrangement 2 Form A
2 Form B
3 Form A
1 Form B
4 Form A
2 Form B
5 Form A
1 Form B
3 Form A
3 Form B
Contact resistance (initial) Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material Au flashed AgSnO2 type
Contact rating (resistive) 6 A 250 V AC, 6 A 30 V DC
Max. switching power (resistive) 1,500 VA, 180 W
Max. switching voltage 250 V AC, 125 V DC
Max. switching current 6 A (Reduce by 0.1 A/°C for temperatures 70 to 85°C)
Min. switching load
(reference value) *1
1 mA 5 V DC
Insulation resistance (initial) Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength (initial) Between open contacts 1,500 Vrms for 1 min (detection current: 10 mA)
Between contact sets 7-8/9-10 between open contacts
2,500 Vrms for 1 min
(detection current: 10 mA)
7-8/11-12 between open contacts
9-10/13-14 between open contacts
11-12/13-14 between open contacts
2,500 Vrms for 1 min (detection current: 10 mA)
3-4/5-6 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
4,000 Vrms for 1 min
(detection current: 10 mA)
3-4/5-6 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
7-8/9-10 between open contacts
4,000 Vrms for 1 min (detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min (detection current: 10 mA)
Time characteristics (initial) Operate time Max. 20 ms at rated coil voltage (at 20°C, without bounce)
Response time*2 Max. 8 ms at rated coil voltage (at 20°C, without bounce, without diode) *4
Release time Max. 20 ms at rated coil voltage (at 20°C, without bounce)
Shock resistance Functional 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance Functional 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of 1.5 mm)
Expected life Mechanical life Min. 10 x 106 ope. (switching frequency: at 180 times/min)
Conditions Conditions for usage, transport and storage*3 Ambient temperature: -40 to +85°C
Humidity: 5 to 85% RH (Avoid icing and condensation) *5
Unit weight Approx. 20 g Approx. 23 g
*1This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Response time is the time after the coil voltage turns off until the time when form A contact turns off.
*3The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value.
Refer to "7.Usage, transport and storage conditions" in SF Relays Cautions For Use.
*4Response time of with diode type is Max. 12 ms (without bounce when rated coil voltage is applied).
*5When the temperature is 70 to 85°C, reduce the max. continuous carrying current by 0.1 A/°C.

Return to top

Electrical life

Type load Switching capacity Number of operations
2 Form A 2 Form B
3 Form A 1 Form B
4 Form A 2 Form B
5 Form A 1 Form B
3 Form A 3 Form B
Resistive load 6 A 250 V AC Min. 100 x 103 ope.
(switching frequency at 20 times/min)
6 A 30 V DC Min. 100 x 103 ope.
(switching frequency at 20 times/min)
1 A 250 V AC Min. 500 x 103 ope.
(switching frequency at 30 times/min)
1 A 30 V DC Min. 500 x 103 ope.
(switching frequency at 30 times/min)
AC 15: inductive load 2 A 240 V AC Min. 100 x 103 ope.
(switching frequency at 20 times/min, cosΦ = 0.3)
DC 13: inductive load 1 A 24 V DC Min. 100 x 103 ope.
(switching frequency at 20 times/min, L/R = 48 ms)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)