AUTOMATION
CONTROLS

Search
Discontinued
Products



HY Relays

Coil data

  • Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.
    Therefore, please use the relay within ± 5% of rated coil voltage.
  • ‘Initial’ means the condition of products at the time of delivery.
Type Rated coil voltage Operate voltage
(at 20℃)
Release voltage
(at 20℃)
Rated operating current
(±10%, at 20℃)
Coil resistance
(±10%, at 20℃)
Rated operating power Max. allowable voltage
(at 70℃)
150 mW 1.5 V DC Max. 75% V of rated coil voltage
(Initial)
Min. 10% V of rated coil voltage
(Initial)
100 mA 15 Ω 150 mW 140% V of rated coil voltage
3 V DC 50 mA 60 Ω
4.5 V DC 33.3 mA 135 Ω
5 V DC 30 mA 166 Ω
6 V DC 25 mA 240 Ω
9 V DC 16.7 mA 540 Ω
12 V DC 12.5 mA 960 Ω
24 V DC 6.25 mA 3,840 Ω
200 mW 1.5 V DC Max. 75% V of rated coil voltage
(Initial)
Min. 10% V of rated coil voltage
(Initial)
133.3 mA 11.25 Ω 200 mW 120% V of rated coil voltage
3 V DC 66.7 mA 45 Ω
4.5 V DC 44.5 mA 101.2 Ω
5 V DC 40 mA 125 Ω
6 V DC 33.3 mA 180 Ω
9 V DC 22.2 mA 405 Ω
12 V DC 16.7 mA 720 Ω
24 V DC 8.3 mA 2,880 Ω

Return to top

Specifications

Item Specifications
Contact data Contact arrangement 1 Form C
Contact resistance
(initial)
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material Ag+Au clad
Contact rating
(resistive)
1 A 30 V DC
Max. switching power
(resistive)
30 W (DC)
Max. switching voltage 60 V DC
Max. carrying current 2 A
Max. switching current
(resistive load)
1 A 30 V DC
Min. switching load
(reference value)*1
1 mA 1 V DC
Insulation resistance
(initial)
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Electrical
characteristics
Dielectric strength
(initial)
Between open
contacts
500 Vrms for 1 min (detection current: 10 mA)
Between contact and coil 1,000 Vrms for 1 min (detection current: 10 mA)
Operate time (at 20℃) Max. 5 ms (at rated coil voltage, without bounce)
Release time (at 20℃) Max. 4 ms (at rated coil voltage, without bounce, without diode)
Mechanical characteristics Shock
resistance
Functional 98 m/s2 [10G] (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive 980 m/s2 [100G] (half-sine shock pulse: 6 ms)
Vibration
resistance
Functional 10 to 55 Hz (at double amplitude of: 1 mm, detection time: 10 μs)
Destructive 10 to 55 Hz (at double amplitude of: 2 mm)
Expected life Mechanical life Min. 10 × 106 (Switching frequency: 180 times/min)
Electrical life Min. 100 × 103 (1 A 30 V DC resistive) (at 20 cpm)
Conditions Conditions for usage,
transport and storage *2
Ambient temperature:
–40 to +70℃, Humidity: 5 to 85% RH (Avoid icing and condensation)
Max. operating speed 20 cpm at rated load
Unit weight Approx. 1.8 g
*1This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2The ambient temperature upper limit is the highest temperature that can satisfy the coil temperature rise value. Please refer to “Regarding ambient temperature” in the“GUIDELINES FOR RELAY USAGE”.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)