Business > Industrial Devices > Automation Controls Top > Components & Devices > Switches > Non Seal Type Switches > AH1 (FJ) Switches > Rating/Performance
|
Standard rating | Minimum rating | ||
---|---|---|---|
AgNi alloy contact type | (OF) 0.74N type | 1A 125V AC, 1A 30V DC | - |
(OF) 1.47N type | 3A 125V AC, 2A 30V DC | - | |
AgNi alloy + Au-clad contact type | 0.1A 125V AC, 0.1A 30V DC | 5mA 6V DC, 2mA 12V DC, 1mA 24V DC |
|
* | Note) OF: Value of pin plunger Note: The diagram above is intended as a reference. Please use the product within the rated voltage and current. |
---|
Item | AgNi alloy contact type | AgNi alloy + Au-clad contact type | |
---|---|---|---|
Expected life |
Mechanical life (OT) Specified value |
(OF) 0.74 N type: Min. 106 (at 60 cpm) (OF) 1.47 N type: Min. 5 × 105 (at 60 cpm) |
|
Electrica (OT) Max. | Min. 3 × 104 (at 20 cpm) (at rated load) |
Min. 105 (at 20 cpm) (at rated load) |
|
Insulation resistance | Min. 100 MΩ (at 500V DC) | ||
Dielectric strength |
Between non-continuous terminals | 600 Vrms for 1 min. | |
Between each terminal and other exposed metal parts | 1,500 Vrms for 1 min. | ||
Between each terminal and ground | 1,500 Vrms for 1 min. | ||
Contact resistance (Initial) | Max. 30 mΩ (by voltage drop, 1A 6 to 8V DC) |
Max. 100 mΩ (by voltage drop, 0.1A 6 to 8V DC) |
|
Vibration resistance (Pin pluger type) | 10 to 55 Hz at single amplitude of 0.75mm (Contact opening: Max. 1 msec.) | ||
Shock resistance (Pin plunger type) | Min. 294m/s2(Contact opening: Max. 1 msec.) | ||
Allowable operating speed (No load) | 1 to 500 mm/sec. | ||
Max. operating cycle rate (No load) | 120 cpm | ||
Ambient temperature | -25 to +85°C (no freezing and condensing) | ||
Unit weight | Approx. 0.5g | ||
Protection grade | IP40 |
*1 | Test conditions and judgement are in accordance with NECA C 4505. |
---|---|
*2 | OF: Value of pin plunger type |
3th digit of Part No. | Operating Force (OF) Max. | Release Force (RF) Min. | Pretravel (PT) Max. | Movement Differential (MD) Max. | Overtravel (OT) Min. | Operating Position (OP) |
---|---|---|---|---|---|---|
6 | 1.47 N | 0.20N | 0.5 mm | 0.12 mm | 0.25 mm | 7±0.3 mm (Distance from stand-off) 5.5±0.2 mm (Distance from mounting hole) |
8 | 0.74N | 0.098N | 7±0.3 mm (Distance from stand-off) 5.5±0.2 mm (Distance from mounting hole) |
3th digit of Part No. | Operating Force (OF) Max. | Release Force (RF) Min. | Pretravel (PT) Max. | Movement Differential (MD) Max. | Overtravel (OT) Min. | Operating Position (OP) |
---|---|---|---|---|---|---|
6 | 0.49N | 0.049N | 2.1 mm | 0.5 mm | 0.55 mm | 8.3±1.2 mm (Distance from stand-off) 6.8±1.0 mm (Distance from mounting hole) |
8 | 0.25N | 0.025N | 8.3±1.2 mm (Diastance from stand-off) 6.8±1.0 mm (Distance from mounting hole) |
3th digit of Part No. | Operating Force (OF) Max. | Release Force (RF) Min. | Pretravel (PT) Max. | Movement Differential (MD) Max. | Overtravel (OT) Min. | Operating Position (OP) |
---|---|---|---|---|---|---|
6 | 0.54N | 0.039N | 2.1 mm | 0.5 mm | 0.5 mm | 11.0±1.2 mm (Distance from stand-off) 9.5±1.0 mm (Distance from mounting hole) |
8 | 0.26N | 0.020N | 11.0±1.2 mm (Distance from stand-off) 9.5±1.0 mm (Distance from mounting hole) |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)