AV4 (FU) Switches

1.P/C board terminal

Straight terminal Pin plunger

Straight terminal Pin plunger

External dimensions

General tolerance: ±0.15

Straight terminal Pin plunger
Pretravel (PT) Max. 0.3 mm
Movement Differential (MD) Max. 0.1 mm
Overtravel (OT) Min. 0.1 mm
Operating Position (OP) 4.8±0.15 mm
Free Position (FP) Max. 5.2 mm
P/C board pattern
P/C board pattern

Hinge lever type


External dimensions

General tolerance: ±0.15

Hinge lever type
*All other dimensions are the same as those of pin plunger type.
Pretravel (PT) Max. 2.4 mm
Movement Differential (MD) Max. 0.7 mm
Overtravel (OT) Min. 0.4 mm
Operating Position (OP) 5.8±0.7 mm
Free Position (FP) Max. 7.5 mm

Simulated roller lever type


External dimensions

General tolerance: ±0.15

Simulated roller lever type
*All other dimensions are the same as those of pin plunger type.
Pretravel (PT) Max. 2.2 mm
Movement Differential (MD) Max. 0.7 mm
Overtravel (OT) Min. 0.3 mm
Operating Position (OP) 6.1±0.7 mm
Free Position (FP) Max. 8.0 mm
CAD Data List

Return to top

2.Angle terminal

Right angle terminal Pin plunger


External dimensions

General tolerance: ±0.15

Right angle terminal Pin plunger
*All other dimensions of hinge lever type and simulated roller lever type are the same as those of straight terminal types.
Pretravel (PT) Max. 0.3 mm
Movement Differential (MD) Max. 0.1 mm
Overtravel (OT) Min. 0.1 mm
Operating Position (OP) 4.8±0.15 mm
Free Position (FP) Max. 5.2 mm

Left angle terminal Pin plunger


External dimensions

General tolerance: ±0.15

Left angle terminal Pin plunger
*All other dimensions of hinge lever type and simulated roller lever type are the same as those of straight terminal types.
Pretravel (PT) Max. 0.3 mm
Movement Differential (MD) Max. 0.1 mm
Overtravel (OT) Min. 0.1 mm
Operating Position (OP) 4.8±0.15 mm
Free Position (FP) Max. 5.2 mm
CAD Data List

Return to top

3.Solder terminal with mounting holes

Pin plunger


External dimensions

General tolerance: ±0.15

Pin plunger
Pretravel (PT) Max. 0.3 mm
Movement Differential (MD) Max. 0.1 mm
Overtravel (OT) Min. 0.1 mm
Operating Position (OP) 5.4±0.15 mm
Free Position (FP) Max. 5.8 mm

Hinge lever


External dimensions

General tolerance: ±0.15

Hinge lever
*All other dimensions are the same as those of pin plunger type.
Pretravel (PT) Max. 2.4 mm
Movement Differential (MD) Max. 0.7 mm
Overtravel (OT) Min. 0.4 mm
Operating Position (OP) 6.4±0.6 mm
Free Position (FP) Max. 9.0 mm

Simulated roller lever


External dimensions

General tolerance: ±0.15

Simulated roller lever
*All other dimensions are the same as those of pin plunger type.
Pretravel (PT) Max. 2.2 mm
Movement Differential (MD) Max. 0.7 mm
Overtravel (OT) Min. 0.3 mm
Operating Position (OP) 6.7±0.5 mm
Free Position (FP) Max. 9.4 mm
CAD Data List

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)