Business > Industrial Devices > Automation Controls Top > Components & Devices > Switches > Seal Type Switches > Turquoise Stroke Switches > Rating/Performance
|
1 mA 5 V DC to 100 mA 30 V DC
Note: Please consult us regarding 42 V DC rating.
Item | Specifications |
---|---|
Ambient and storage temperature |
-40°C to +85°C (no freezing and condensing) |
Allowable operating speed |
30 to 500 mm/sec. |
Max. operating cycle rate |
120 cpm |
* | When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly depending on the load capacity. Please consult us. |
---|
Dielectric strength (Initial) | Between non-continuous terminals: 600 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms, Between each terminal and ground: 1,500 Vrms (at detection current of 1 mA) |
---|---|
Insulation resistance (Initial) | Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.) |
Contact resistance (Initial) | Max. 1 Ω (by voltage drop 0.1 A 6 to 8 V DC) |
Item | Specifications | ||
---|---|---|---|
Electrical switching life |
5 V DC 1 mA (Resistive load) |
Min. 5 x 105 Note 1) |
Switching frequency: 20 times/min. Conduction ratio: 1:1 Pushbutton operation speed: 100 mm/s Pushbutton switching position: free position (FP) to operation limit position (TTP) |
16 V DC 50 mA (Resistive load) | Min. 5 x 105 Note 2) | ||
30 V DC 100 mA (Resistive load) | Min. 2 x 105 Note 2) | ||
Vibration resistance (malfunction vibration resistance) |
Single amplitude: 0.75 mm Amplitude of vibration: 10 to 55 Hz (4 minutes cycle) Direction and time: 30 minutes each in X, Y and Z directions |
||
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle) Acceleration: 43.1 m/s2 Direction and time: 30 minutes each in X, Y and Z directions |
|||
Shock resistance (malfunction shock resistance) |
Shock value: 980 m/s2 Direction and time: 5 times each in X, Y and Z directions |
||
Vibration resistance endurance |
Frequency of vibration: 33.3 Hz, Acceleration: 43.1 m/s2 Direction and time: 8 hours each in X, Y and Z directions |
||
Terminal strength | 6 N min. (each direction) *Terminal deformation possible. | ||
Heat resistance | 85°C 500 houres | ||
Cold resistance | -40°C 500 houres | ||
Humidity resistance | 40°C 95% RH 500 houres | ||
Thermal shock resistance | 30 min. at 85°C to 30 min at -40°C for 1,000 cycles | ||
Unit weight | Approx. 0.8 g (terminal type), Approx. 5.4 g (wire leads side type) | ||
Protection grade | IP67 (except exposed terminal part of terminal type) |
* | As long as there are no particular designations, the following conditions apply to the test environment. • Ambient temperature: 5 to 35°C • Relative humidity: 25 to 85% RH • Air pressure: 86 to 106 kPa |
---|
Note 1: | Switching life for single switching (COM-N.C. or COM-N.O. connection) and double switching (COM-N.C. and COM-N.O. connection). | |
Note 2: | Switching life is for single switching life. For double switching it is greater than 105 times. |
Note 1) | A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 1 m of water (with temperature difference between water and switch no larger than 5°C). | |
Note 2) | A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 10 minutes under 10 cm water (with temperature difference between water and switch no larger than 30°C). |
Characteristics | Pin plunger | Leaf leve | Simulated leaf lever | |
---|---|---|---|---|
Operating Force (OF) Max. *Note 2 |
1.5 mm | 1.7 mm | 1.5 mm | |
Total travel Force (TF) Max. (reference value) |
(2.0 N) | (3.1 N) | (2.8 N) | |
Free Position (FP) Max. |
From mounting boss and hole center line |
9.2 mm | 11.5 mm | 14.4 mm |
From standoff |
13.4 mm | 15.7 mm | 18.6 mm | |
Operating Position on N.C. side (OP (N.C.) ) *Note 3 |
From mounting boss and hole center line |
8.7±0.3 mm | 9.8±0.5 mm | 12.5±0.5 mm |
From standoff |
12.9±0.3 mm | 14.0±0.5 mm | 16.7±0.5 mm | |
Operating Position on N.O. side (OP (N.O.) ) *Note 4 |
From mounting boss and hole center line |
8.4±0.3 mm | 9.3±0.5 mm | 12.0±0.5 mm |
From standoff |
12.6±0.3 mm | 13.5±0.5 mm | 16.2±0.5 mm | |
Release Position on N.C. side (RP (N.C.) ) *Note 5 |
From mounting boss and hole center line |
8.8±0.3 mm | 10.1±0.5 mm | 12.9±0.5 mm |
From standoff |
13.0±0.3 mm | 14.3±0.5 mm | 17.1±0.5 mm | |
Release Position on N.O. side (RP (N.O.) ) *Note 6 |
From mounting boss and hole center line |
8.5±0.3 mm | 9.6±0.5 mm | 12.4±0.5 mm |
From standoff |
12.7±0.3 mm | 13.8±0.5 mm | 16.6±0.5 mm | |
Over travel on N.C. side (OT (N.C.) ) Min. |
2.5 mm | 3.1 mm | 3.3 mm | |
Over travel on N.O. side (OT (N.O.) ) Min. |
2.2 mm | 2.6 mm | 2.8 mm | |
Total Travel Position (TTP) (reference value) |
From mounting boss and hole center line |
(5.9 mm) | (6.2 mm) | (8.7 mm) |
From standoff |
(10.1 mm) | (10.4 mm) | (12.9 mm) |
* |
|
---|
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)