Business > Industrial Devices > Automation Controls Top > Components & Devices > Switches > Seal Type Switches > Turquoise Stroke Mini Switch Resistor installed type > Rating/Performance
|
Please use within the range below.
1) Rated power | : | Environment temperature -40°C ≦ T ≦ 70°C 0.50 W |
---|---|---|
Environment temperature 70°C < T ≦ 75°C 0.45 W | ||
Environment temperature 75°C < T ≦ 85°C 0.40 W | ||
2) Voltage | : | 4.5 to 16 V DC |
3) Minimum current | : | 1 mA |
Item | Specifications |
---|---|
Ambient and storage temperature | –40°C to +85°C (no freezing and condensing) |
Allowable operating speed | 30 to 500 mm/sec. |
Max. operating cycle rate | 120 cpm |
* | When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly depending on the load capacity. Please consult us. |
---|
Item | Specifications | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Circuit diagram | ||||||||||||||||||||||||||
Output resistance (Initial) |
|
|
Item | Specifications | ||
---|---|---|---|
Electrical switching life | DC 4.5 to 5.5 V | Min. 3 × 105 | Switching frequency: 20 times/min Plunger operation speed: 100 mm/s Plunger switching position: Free Position (FP) to Total Travel Position (TTP) |
DC 8 to 16 V | Min. 2 × 105 | ||
Vibration resistance (malfunction vibration resistance) |
Single amplitude: 0.75 mm Amplitude of vibration: 10 to 55 Hz (4 minutes cycle) Direction and time: 30 minutes each in X, Y and Z directions |
||
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle) Acceleration: 43.1 m/s2 Direction and time: 30 minutes each in X, Y and Z directions |
|||
Shock resistance (malfunction shock resistance) |
Shock value: 980 m/s2 Direction and time: 5 times each in X, Y and Z directions |
||
Terminal strength | Min. 6 N (each direction) *Terminal deformation possible. | ||
Heat resistance | 85°C 500 hours | ||
Cold resistance | –40°C 500 hours | ||
Humidity resistance | 40°C 95% RH 500 hours | ||
Unit weight | Approx. 0.5 g (Terminal type), Approx. 4.1 g (Wire leads type) | ||
Protection grade | IP67 (except exposed terminal part of terminal type) |
Notes: As long as there are no particular designations, the following conditions apply to the test environment.
• Ambient temperature: 5 to 35°C
• Relative humidity: 25 to 85% RH
• Air pressure: 86 to 106 kPa
Note 1) | A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 1 m of water (with temperature difference between water and switch no larger than 5°C). |
Note 2) | A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 10 minutes under 10 cm water (with temperature difference between water and switch no larger than 30°C). |
Characteristics | Pin plunger | Simulated roller lever | |
---|---|---|---|
Operating Force (OF) Max. | 1.2 N | 1.5 N | |
Total Travel Force (TF) Max. reference value | (3.0 N) | (2.8 N) | |
Free Position (FP) Max. | Terminal type | 7.7 mm | 13.4 mm |
Wire leads type | 14.45 mm | 20.15 mm | |
Operating Position (OP) | Terminal type | Initial: 7.1±0.25 mm After test: 7.1±0.3 mm |
Initial: 10.75±0.6 mm After test: 10.75±0.7 mm |
Wire leads type | Initial: 13.75±0.35 mm After test: 13.75±0.4 mm |
Initial: 17.4±0.7 mm After test: 17.4±0.8 mm |
|
Release Position (RP) | Terminal type | Initial: 7.15±0.3 mm After test: 7.15±0.35 mm |
Initial: 11.05±0.7 mm After test: 11.05±0.8 mm |
Wire leads type | Initial: 13.8±0.4 mm After test: 13.8±0.45 mm |
Initial: 17.7±0.8 mm After test: 17.7±0.9mm |
|
Over Travel (OT) Min. | Terminal type | Initial: 1.75 mm After test: 1.70 mm |
Initial: 2.25 mm After test: 2.15 mm |
Wire leads type | Initial: 1.65 mm After test: 1.60 mm |
Initial: 2.15 mm After test: 2.05 mm |
|
Total Travel Position (TTP) Reference value |
Terminal type | (5.1 mm) | (7.9 mm) |
Wire leads type | (11.75 mm) | (14.55 mm) |
Note: The above indicates the characteristics when operating the actuator from the vertical direction.
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)