Business > Industrial Devices > Automation Controls Top > Components & Devices > Switches > Power Rocker Switches > AJ7 (J7) Switches > Rating/Performance
|
Type | Contact voltage | Resistive load (Power factor = 1) |
Motor load* (EN61058-1) (Power factor = 0.6) |
Inrush load |
---|---|---|---|---|
10A | AC250V | 10A | 4A | 100A (8.3ms) |
6A | 6A | 3A | — |
* | The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating. |
---|
Contact voltage | Resistive load | Motor load (EN61058-1) | Capacitor load (EN61058-1) |
Lamp load (UL61058-1) | Expected electrical life |
---|---|---|---|---|---|
(Power factor = 1) | (Power factor = 0.6) | (Inrush load) | (TV‐5) | (at 7 cpm) | |
120V AC | — | — | — | 5/78A | Min. 2.5 × 104 |
250V AC | 10A | 4A | 100A (8.3ms) | — | Min. 104 |
Item | Specifications (common to 10 A and 6 A types) | |
---|---|---|
Expected life (Min. operations) |
Mechanical | Min. 5 x 104 (at 20 cpm.) |
Electrical (at rated load)* | Min. 104 (at 7 cpm.) | |
Insulation resistance | Min. 100 MΩ (at 500 V DC measured by insulation resistive meter) (Between terminals) | |
Dielectric strength | Initial, 2,000 Vrms for 1 min (detection current: 10 mA) (Between terminals) | |
Contact resistance | Initial, Max. 100 mΩ (By voltage drop at 1 A, 2 to 4 V DC) | |
Temperature rise (terminal section) | Max. 30°C at 6 x 103 ope. or less (UL61058-1), Max. 55°C from 6 x 103 ope. to 104 (EN61058-1) |
|
Vibration resistance | 10 to 55 Hz at double amplitude of 1.5mm (Contact opening Max. 1 msec.) | |
Shock resistance | Min. 980 m/s2 | |
Actuator strength | 40 N for 1 minute (operating direction) | |
Tensile terminal strength | 100 N for 1 minute or more (Pull & push direction) | |
Ambient temperature | -25°C to +85°C (no freezing and condensing) | |
Flame retardancy | UL94V-0 | |
Tracking resistance | Min. 175 | |
Operating force (reference characteristics) |
1-pole | 2.2 ± 1.2 N |
2-pole | 4 ± 2.5 N | |
Contact material | AgSnO2 alloy |
* | Note: Test conditions and are complying with JIS C 6571, EN61058-1 and UL61058-1. * Except TV rating type |
---|
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)