AUTOMATION
CONTROLS

Search
Discontinued
Products



AJ7 (J7) Switches

Specifications

Contact rating

Type Contact voltage Resistive load
(Power factor = 1)
Motor load* (EN61058-1)
(Power factor = 0.6)
Inrush load
10A AC250V 10A 4A 100A (8.3ms)
6A 6A 3A
*The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating.

TV rating

Contact voltage Resistive load Motor load (EN61058-1) Capacitor load
(EN61058-1)
Lamp load (UL61058-1) Expected electrical life
(Power factor = 1) (Power factor = 0.6) (Inrush load) (TV‐5) (at 7 cpm)
120V AC 5/78A Min. 2.5 × 104
250V AC 10A 4A 100A (8.3ms) Min. 104

Return to top

Characteristics

Item Specifications (common to 10 A and 6 A types)
Expected life
(Min. operations)
Mechanical Min. 5 x 104 (at 20 cpm.)
Electrical (at rated load)* Min. 104 (at 7 cpm.)
Insulation resistance Min. 100 MΩ (at 500 V DC measured by insulation resistive meter) (Between terminals)
Dielectric strength Initial, 2,000 Vrms for 1 min (detection current: 10 mA) (Between terminals)
Contact resistance Initial, Max. 100 mΩ (By voltage drop at 1 A, 2 to 4 V DC)
Temperature rise (terminal section) Max. 30°C at 6 x 103 ope. or less (UL61058-1),
Max. 55°C from 6 x 103 ope. to 104 (EN61058-1)
Vibration resistance 10 to 55 Hz at double amplitude of 1.5mm (Contact opening Max. 1 msec.)
Shock resistance Min. 980 m/s2
Actuator strength 40 N for 1 minute (operating direction)
Tensile terminal strength 100 N for 1 minute or more (Pull & push direction)
Ambient temperature -25°C to +85°C (no freezing and condensing)
Flame retardancy UL94V-0
Tracking resistance Min. 175
Operating force
(reference characteristics)
1-pole 2.2 ± 1.2 N
2-pole 4 ± 2.5 N
Contact material AgSnO2 alloy
*Note: Test conditions and are complying with JIS C 6571, EN61058-1 and UL61058-1.
* Except TV rating type

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)