1) Standard type
Load | Resistive load (cos ø≒1) |
Inductive load (cos ø≒0.4) |
---|---|---|
125V AC | 5A | 3A |
250V AC | 5A | 2A |
125V DC | 0.4A | 0.1A |
2) Types with neon lamp and with LED
Load | Rated control voltage |
Resistive load (cos ø≒1) |
Inductive load (cos ø≒0.4) |
---|---|---|---|
With Neon lamp | 125V AC | 5A | 3A |
240V AC | 5A | 2A | |
With LED | 24V DC | 3A | - |
Contact arrangement | 1 Form A 1 Form B | |
---|---|---|
Initial contact resistance, max. | 15mΩ (By voltage drop 6 to 8V DC at rated current) | |
Contact material | Gold clad silver alloy (cadmium free) | |
Initial insulation resistance (At 500V DC) |
Min. 100MΩ | |
Initial breakdown voltage | 1,000Vrms for 1 min Between non-consecutive terminals 2,000Vrms for 1 min Between dead metal parts and each terminal 2,000Vrms for 1 min Between ground and each terminal | |
Shock resistance max. | In the free position | Max. 98m/s2 {10G} |
In the full operating position | Max. 294m/s2{30G} | |
Vibration resistance | Standard type: Max. 55Hz Type with indicator: 10 to 50Hz, double amplitude of 1.5mm | |
Expected life (Min. operations) |
Mechanical | 107 (at 120 cpm) |
Electrical | 3 x 105 (at rated resistive load) 5 x 106 (Magnetic contactor FC-100 200V AC load) | |
Life of lamp | Min. 2 x 104 hours (Neon lamp type) | |
Ambient temperature/ Ambient humidity |
–20 to +60℃ –4 to +140℉/Max. 95% | |
Max. operating speed | 120 cpm |
Item | Rating |
---|---|
Rated insulation voltage (Ui) | 250VAC |
Rated impulse withstand voltage (Uimp) | 2.5kV |
Switching overvoltage | 2.5kV |
Rated enclosed thermal current (Ithe) | 5A |
Conditional short-circuit current | 100A |
Short-circuit protection device | 10A fuse |
Protective construction | IP64 |
Pollution degree | 3 |
Characteristics | O.F. (N {gf}) max. |
R.F. (N {gf}) min. |
Pretravel (P.T.), max. mm inch |
Movement Diferential (M.D.), max. mm inch |
Overtravel (O.T.), min. mm inch |
Totaltravel (T.T.), min. mm inch |
---|---|---|---|---|---|---|
Push plunger Roller plunger Cross roller plunger |
8.83 {900} | 1.47 {150} | 1.5 .059 | 0.7 .028 | 4 .028 | 5.5 .217 |
Roller arm | 5.88 {600} | 0.49 {50} | 20° | 10° | 75° | 95° |
Adjustable roller arm | 7.84 {800}~3.35 {342} | 0.49 {50}~0.21 {21} | 20° | 10° | 75° | 95° |
Adjustable rod | 7.84 {800}~1.99 {203} | 0.49 {50}~0.12 {12} | 20° | 10° | 75° | 95° |
Flexible rod spring wire | 0.88 {90} | - | 30 (1.181) | - | 20 (.787) | 50 (1.969) |
* | Characteristics measured at bent condition: min. radius 100mm 3.937inch. |
---|---|
Note 1 : | Keep the total travel values in the specified range. Otherwise the actuator force may rise to several times the operating force, resulting in a mechanical failure or much shorter service life. |
Protective construction | VL Mini limit switch | VL Mini limit switch (with lamp) |
---|---|---|
IEC | ||
IP60 | ○ | ○ |
IP64 | ○ | ○ |
Types | Rated operating voltage |
Operating voltage range |
Internal resister |
---|---|---|---|
Neon lamp | 100 to 200V AC | 80 to 240V AC | 120kΩ |
LED | 6V DC | 5 to 15V DC | 2.4kΩ |
12V DC | 9 to 28V DC | 4.7kΩ | |
24 to 48V DC | 20 to 55V DC | 15kΩ |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)