Type Ralay output type Transistor output type
Item AC type AC/DC type DC type AC type AC/DC type DC type
Rating Rated operating voltage 100 to 240 V AC, 24 V AC, 24 V AC/DC 12 to 24 V DC 100 to 240 V AC, 24 V AC, 24 V AC/DC 12 to 24 V DC
Rated frequency 50/60 Hz common - 50/60 Hz common -
Rated power consumption Max. 10 V A Max. 3 W Max. 10 V A Max. 3 W
Rated control capacity 5 A, 250 V AC (resistive load) 100 mA, 30 V DC
Time range 9.999 s, 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 999.9 min, 99 h 59 min, 999.9 h (selected by DIP switch)
Time counting direction Addition (UP)/Subtraction (DOWN)
(2 directions selectable by DIP switch)
Operation mode A (Power ON delay 1), A2 (Power ON delay 2), B (Signal ON delay), C (Signal OFF delay), D (Pulse one-shot), E (Pulse ON delay), F (Signal Flicker), G (Totalizing ON delay) (selectable by DIP switch)
Start/Reset/Stop input Min. input signal width: 1 ms, 20 ms (2 directions by selected by DIP switch) (The 8-pin type does not have a stop input.)
Lock input Min. input signal width: 20 ms (The 8-pin type does not have a lock input.)
Input signal Open collector input Input impedance: Max. 1 kΩ; Residual voltage: Max. 2 V
Open impedance: 100kΩ or less, Max. energized voltage: 40V DC
Indication 7-segment LCD (LT4H, LT4H-L common), Elapsed value (backlight red LED), Setting value (backlight yellow LED)
Power failure memory method EEP-ROM (Min. 105 overwriting)
Time accuracy (max.) Operating time fluctuation ± (0.005 % + 50 ms) in case of power on start
± (0.005 % + 20 ms) in case of input signal start
[Operating voltage: 85 to 110% Temperature: -10 to +55°C/ +14 to +131°F Min. input signal width: 1ms]
Temperature error
Voltage error
Setting error
Contact Contact arrangement Timed-out 1 Form C Timed-out 1 Form A (Open collector)
Contact resistance (Initial value) 100 mΩ (at 1 A 6 V DC) -
Contact material Ag alloy/Au flash -
Life Mechanical (contact) Min. 2 × 107 ope. (Except for switch operation parts) -
Electrical (contact) 1.0 × 105 ope. (At rated control voltage) Min. 107 ope. (At rated control voltage)
Electrical Allowable operating voltage range 85 to 110 % of rated operating voltage
Breakdown voltage
(Initial value)
2,000 Vrms for 1 min: Between live and dead metal parts (11-pin)
2,000 Vrms for 1 min: Between input and output
1,000 Vrms for 1 min: Between contacts
2,000 Vrms for 1 min: Between live and dead metal parts (Pin type)
2,000 Vrms for 1 min: Between input and output
Insulation resistance
(Initial value)
Min. 100 MΩ:
Between live and dead metal parts
Between input and output
Between contacts
(At 500V DC)
Min. 100 MΩ:
Between live and dead metal parts Between input and output
(At 500V DC)
Operating voltage reset time Max. 0.5 s
Temperature rise Max. 65° C (under the flow of nominal operating current at nominal voltage) -
Mechanical Vibration resistance Functional 10 to 55 Hz: 1 cycle/min single amplitude of 0.35 mm .014 inch (10 min on 3 axes)
Destructive 10 to 55 Hz: 1 cycle/min single amplitude of 0.75 mm .030 inch (1 h on 3 axes)
Shock resistance Functional Min. 98 m 321.522 ft./s2 (4 times on 3 axes)
Destructive Min. 294 m 964.567 ft./s2 (5 times on 3 axes)
Operating conditions Ambient temperature -10°C to 55°C/ +14°F to +131°F
Ambient humidity Max. 85 % RH (non-condensing)
Air pressure 860 to 1,060 h Pa
Ripple rate - 20 % or less - 20 % or less
Connection 8-pin/11-pin/screw terminal
Protective construction IP66 (front panel with rubber gasket)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)