Discontinuation plan
|
|
Item | Unit | Data display range | |
---|---|---|---|
Instantaneous electric power (Active) | kW | 0.00 to 9999.99 | |
Integrated electric power (Active) | kWh/MWh | 0.00 to 9999.99 MWh 0.00 to 9999999.99 kWh (when 9-digit display) |
|
Current | R-current | A | 0.0 to 6000.0 |
S-current (Note 1) | A | 0.0 to 6000.0 | |
T-current | A | 0.0 to 6000.0 | |
Voltage | R (RS)-voltage | V | 0.0 to 9999.9 |
S (RT)-voltage (Note 1) | V | 0.0 to 9999.9 | |
T (TS)-voltage | V | 0.0 to 9999.9 | |
Electricity charge (Note 2) | - | 0.00 to 999999 | |
Conversion carbon dioxide value | kg-CO2 | 0.00 to 999999 | |
Power factor (Note 1) | - | 0.00 to 1.00 [Identify leading phase (–) or lagging phase] (Only in range of phase angle θ = –90° to +90°) |
|
Frequency (Note 1) | - | 47.5 to 63.0 Hz | |
Hour meter | ON-time | h (Hour) | 0.0 to 99999.9 |
OFF-time | h (Hour) | 0.0 to 99999.9 | |
Pulse counter (Note 1) | - | 0 to 999999 |
Note: 1) Excluding AKW1110(B).
Note: 2) Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing.
Item | AKW1111(B) | AKW1110(B) |
---|---|---|
Rated operating voltage | 100 to 240V AC | |
Rated frequency | 50 / 60 Hz common | |
Rated power consumption |
6 VA (AKW1110(B)), 8 VA (AKW1111(B)) (240 V AC at +25 ℃ +77 ℉) | |
Allowable operating voltage range | 85 to 264 V AC (85 % to 110 % of rated operating voltage) | |
Allowable momentary power-off time | 10 ms | |
Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (-25 to +70 ℃ -13 to +158 ℉ at storage) |
|
Ambient humidity | 30 to 85 % RH (at +20 ℃ +68 ℉ non-condensing) | |
Breakdown voltage(initial) | Between the isolated circuits:2000V for 1min | A)Outer edge (case)-All terminals B)Between Insulated circuit ・Operating power supply terminals- Analog input terminals ・RS485-All other terminals ・Pulse output terminals-All other terminals |
Insulation resistance(initial) | Between the isolated circuits: 100MΩor more(measured at 500V DC) |
|
Vibration resistance | 10 to 55Hz (1cycle/min) single amplitude : 0.375mm(1h on 3 axes) | |
Shock resistance | Min. 294m/s2 (5 times on 3 axes) | |
Display method | LCD with backlight Upper: green, 4-digit, 16-segment Lower: amber, 6-digit, 7-segment |
|
Power failure memory method |
EEPROM (more than 100,000 overwrite) | |
Weight | 170 g approx. |
Item | Specifications | |||
---|---|---|---|---|
AKW1111(B) | AKW1110(B) | |||
Phase and wire system | Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Three-phase four-wire system (common) |
Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system (common) |
||
Input voltage |
Rating | 1P2W : 0-440V AC (Line voltage) 1P3W : 0-220V AC (Phase voltage) 3P3W : 0-440V AC (Line voltage) 3P4W : 0-254V AC (Phase voltage) |
1P2W : 0-220V AC (Line voltage) 1P3W : 0-110V AC (Phase voltage) 3P3W : 0-220V AC (Line voltage) |
|
Allowable measurement voltage |
Up to 120% of rated input voltage | |||
1P2W : 0-528V AC (Line voltage) 1P3W : 0-264V AC (Phase voltage) 3P3W : 0-528V AC (Line voltage) 3P4W : 0-300V AC (Phase voltage) |
1P2W : 0-264V AC (Line voltage) 1P3W : 0-132V AC (Phase voltage) 3P3W : 0-264V AC (Line voltage) |
|||
VT ratio | 1.00 to 99.99 (Set with setting mode) *Voltage transformer (VT) is required when you measure a load with voltage over the allowable measurement voltage. *Secondary current rating of commercial VT is 110V. |
|||
Input current | Primary side rating |
<Using the dedicated CT> ・5A/50A/100A/250A/400A/600A (Select with setting mode) <Using a commercial CT with the secondary side current 5A> ・1 to 4000A (Set with setting mode) *Use a CT with secondary side current of 5A when measure 600A or more. |
||
Special functions |
Cut-off current | 1.0 to 50.0%F.S (Set with setting mode) | ||
Cut-off voltage | Below 5% of rating voltage (Rating voltage x 0.05 x VT ratio) (Fixed) |
|||
Current threshold for hour meter |
1.0 to 100.0%F.S. | |||
Accuracy (without error in CT and VT) |
Indication accuracy | Instantaneous electric power, Integrated electric power, Conversion electricity charge value, Conversion carbon dioxide value |
Within ± (2.0 % F.S. + 1 digit) (at +20 ℃ +68 ℉, rated input, rated frequency, power factor 1) (Note) | |
Current | Within ± (1.0 % F.S. + 1 digit) (at +20 ℃ +68 ℉ rated input, rated frequency, power factor 1) (Note) | |||
Voltage | Within ± (1.0 % F.S. + 1 digit) (at +20 ℃ +68 ℉ rated input, rated frequency, power factor 1) | |||
Hour meter | Within ± (0.01 % +1 digit) (at +20 ℃ +68 ℉) (In case power on start or current energizing: ± 0.01 % + 1 sec + 1 digit) | |||
Temperature characteristics |
Within ± (1.0 % F.S. / +10 ℃ +50 ℉ + 1 digit) (Range of -10 to +50 ℃ +14 to +122 ℉, rated input, power factor 1) In case of 5 A CT mode, within ± (1.5 % F.S. + 1 digit) under the same condition |
|||
Frequency characteristics |
Within ± (1.0 % F.S. + 1 digit) (Frequency change ± 5 % based on rated frequency, rated input, power factor 1) In case of 5 A CT mode, within ± (1.5 % F.S. + 1 digit) under the same condition |
Note: Accuracy coverage: 5 to 100 % of rated current
In case of 5 A CT mode, within ± (2.5 % F.S. + 1 digit) under the same condition
Item | Specifications | |
---|---|---|
Input mode | Addition (Fixed) | |
Max. counting speed | 2 kHz / 30 Hz (Select with setting mode) | |
Pulse input (Min. input signal width) |
0.25 ms (When 2 kHz selected) / 16.7 ms (When 30 Hz selected), ON : OFF ratio = 1 : 1 | |
Input signal (at +20 ℃ +68 ℉) |
Contact / No contact (open collector) - Impedance when shorted: Max. 1 kΩ - Residual voltage when shorted: Max. 2 V - Impedance when open: Min. 100 kΩ |
|
Mode | HOLD (Over count) | |
Prescale | Decimal point | Setting possible up to under 3-digit |
Range | 0.001 to 100.000 (Set with setting mode) |
Item | Specifications | |
---|---|---|
AKW1111(B) | AKW1110(B) | |
Number of output point | 1 point | |
Insulation method | Optical coupler | |
Output type | Open collector | |
Output capacity | 100mA 30V DC | |
Pulse width | approx. 100ms | |
ON state voltage drop | 1.5V or less | |
OFF state leakage current | 100μA or less | |
Pulse output unit | 0.001/0.01/0.1/1/10/100kWh/ Alarm(AL-P)/ Current alarm(AL-C)/ Stand-by alarm (AL-S) / Counter output (Cnt) (Selectable with setting mode) |
0.001/0.01/0.1/1/10/100kWh/ Alarm(AL-P)/ Current alarm(AL-C) (Selectable with setting mode) |
* We recommend the setting of minimum unit for pulse output for measurement shown as below.
Output pulse: 4 pulse or less per 1sec.
-How to calculate-
(Unit for pulse output: PL-P) > (Max. measurement power [kW])/(3600[s]×4 [pulse/s])
Note :1) Improper unit setting may cause miss counting.
Note :2) If the OFF time is too short, there is a possibility of counting errors.
Item | Specifications |
---|---|
RS485 communication | |
Protocol | MEWTOCOL and Modbus RTU (selectable with setting mode) |
Isolation status | Isolated with the internal circuit |
Number of connected units | Max. 99 units (Note 1) (Note 2) |
Transmission distance / Transmission speed |
1,200 m 3,937 ft (Note 3) / 2,400 / 4,800 / 9,600 / 19,200 / 38,400 bps (selectable with setting mode) |
Transmission format | Data length: 8-bit / 7-bit (selectable with setting mode) (Note 4), Parity: Not available / Odd number / Even number (selectable with setting mode), Stop bit: 1 bit (fixed) |
Communication method / Synchronous system |
Half-duplex / Synchronous communication method |
Ending resistance | 120 Ω approx. (built-in) |
Notes:
1) | For RS-485 converter on the computer side, we recommend SI-35 and SI-35USB (from LINE EYE Co., Ltd.). |
---|---|
2) | When using SI-35,SI-35USB or our PLC (which can be connected up to 99 units), up to 99 Eco-POWER METER can be connected. (However, 32 units max. using connection with C-NET adapter) In case using this system with the other devices, up to 31 Eco-POWER METER can be connected. |
3) | Please check with the actual devices when some commercial devices with RS-485 interface are connected. The number of connected devices, transmission distance, transmission speed may be different according to using devices or transmission line. |
4) | With Modbus RTU protocol for RS-485 communication, it works only with data length 8-bit. |
* Modbus Protocol is a communications protocol developed for PLCs by Modicon Inc.
Item | Clamp-on typ | ||||
---|---|---|---|---|---|
AKW4801B AKW4801C |
AKW4802B AKW4802C |
AKW4803B AKW4803C |
AKW4804B AKW4804C |
AKW4808B AKW4808C |
|
CE marking directive compliance | Low Voltage Directive, RoHS Directive | ||||
Primary side rated current | 5A/50A | 100A | 250A | 400A | 600A |
Secondary side rated current | 1.67mA/16.7mA | 33.3mA | 125mA | 200mA | 200mA |
Winding (Turn) | 3000 | 3000 | 2000 | 2000 | 3000 |
Ratio error | ±2.0%F.S. | ||||
Through hole | ø10 ø0.39 | ø16 ø0.63 | ø24 ø0.94 | ø36 ø1.42 | ø36 ø1.42 |
Breakdown voltage (initial) | 1000V AC/1min (Between through hole and output lead wire) |
2000V AC/1min (Between through hole and output lead wire) |
|||
Insulation resistance (initial) | Min. 100 M Ω (at 500 V DC) (Between through hole and output lead wire) | ||||
Functional vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes) | ||||
Vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) | ||||
Functional shock resistance | Min. 98m/s2(4 times on 3 axes) | ||||
Shock resistance | Min. 294m/s2(5 times on 3 axes) | ||||
Output protection level | ±7.5 V with clamp element | ±3.0V with clamp element | |||
Permissible clamping frequency | 100 times approx. | ||||
Ambient temperature range | -10 to +50℃ +14 to +122 ℉ (without frost and non-condensing) | ||||
Storage temperature | -20 to +60℃ -4 to +140 ℉ (without frost and non-condensing) | ||||
Ambient humidity | 35 to 85%RH(at +20℃ +68 ℉ non-condensing) | ||||
Dimensions (mm in) (W x H x D) |
23 x 40 x 26.5 0.08 x 0.13 x 0.09 |
30 x46.5 x 32 0.10 x 0.15 x 0.11 |
45 x65 x 34 0.15 x 0.21 x 0.11 |
57 x81 x 38 0.19 x 0.27 x 0.12 |
62.6 x93.3 x 40 0.21 x 0.31 x 0.13 |
Weight (Relay cable included) |
60 g approx. | 90 g approx. | 200 g approx. | 295 g approx. | 450 g approx. |
Item | Through type | |||
---|---|---|---|---|
AKW4506B AKW4506C |
AKW4507B AKW4507C |
AKW4508B AKW4508C |
||
CE marking directive compliance | Low Voltage Directive, RoHS Directive | |||
Primary side rated current | 50A/100A | 250A/400A | 600A | |
Secondary side rated current | 16.7mA/33.3mA | 125mA/200mA | 200mA | |
Winding (Turn) | 3000 | 2000 | 3000 | |
Ratio error | ±1.0%F.S. | |||
Through hole | ø17mm ø0.67 in | ø36mm ø1.42 in | ||
Breakdown voltage (initial) | 1000V AC/1min (Between through hole and output lead wire)) |
2000V AC/1min (Between through hole and output lead wire) |
||
Insulation resistance (initial) | Min. 100 MΩ (at 500 V DC megger) (Between through hole and output lead wire) | |||
Functional vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes) | |||
Vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) | |||
Functional shock resistance | Min. 98 m/s2 (4 times on 3 axes) | |||
Shock resistance | Min. 294 m/s2 (5 times on 3 axes) | |||
Output protection level | ±7.5 V with clamp element | ±3.0 V with clamp element | ||
Permissible clamping frequency | - | |||
Ambient temperature range | –10 to +50 ℃ +14 to +122 ℉ (without frost and non-condensing) | |||
Storage temperature | –20 to +60 ℃ –4 to +140 ℉ (without frost and non-condensing) | |||
Ambient humidity | 35 to 80 % RH (at +20 ℃ +68 ℉non-condensing) | |||
Dimensions (mm in) (W x H x D) |
ø42 x 15 1.65 x 0.05 |
ø70 x19 2.76 x 0.06 |
ø70 x19 2.76 x 0.06 |
|
Weight (Relay cable included) |
70 g approx. | 200 g approx. | 215 g approx. |
Notes :
1) | Dedicated CT are dedicated for low voltage under 440 V AC system. They can not be used for high voltage circuit. |
---|---|
2) | In each type of Eco-POWER METER excluding AKW8115, KW9M and KW2M, a combination of commercially secondary side 5 A CTs and dedicated CTs for 5 A is used for measuring high voltage circuits; For details, confirm with each respective user's manual. |
3) | Since dedicated CTs cannot be used when measuring with AKW8115, KW9M and KW2M, please be careful and do not purchase a dedicated CT by mistake. |
4) | For the AKW8115, KW9M and KW2M, CT with a secondary side current 1 A or 5 A is recommended. Please confirm the specification beforehand. |
5) | Dedicated CT are not included with Eco-POWER METERs. |
6) | Each dedicated CT includes a 1 m 3.281 ft relay cable, respectively. |