Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Measurement Sensors > Measurement Sensors > Ultra High-speed Laser Displacement Sensor HL-C1(Discontinued Products) > Specifications
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
|
Type | Diffuse reflective type | |||
Wide range | General purpose | High precision | ||
Model No. | IEC / JIS standards conforming type | HL-C135C-BK10 | HL-C108B-BK | HL-C105B-BK |
FDA regulations conforming type | HL-C108F-BK | HL-C105F-BK | ||
Measurement center distance | 350 mm 13.780 in | 85 mm 3.346 in | 50 mm 1.969 in | |
Measuring range | ±200 mm 7.874 in | ±20 mm ±0.787 in | ±5 mm ±0.197 in | |
Resolution (Note 2, 3) | 10 μm 0.394 mil | 2 μm 0.079 mil | 1 μm 0.039 mil | |
Linearity (Note 4) | ±0.1 % F.S. | |||
Temperature characteristics | 0.02 % F.S./℃ | |||
Laser emission indicator | Green LED (lights up during laser emission or immediately before laser emission) |
|||
Measuring range indicator | Yellow LED [blinks within the measuring range and lights up when near the measurement center distance] |
|||
Pollution degree | 3 (Industrial environment) | |||
Protection | IP67 (IEC)(excluding the connector) | |||
Ambient temperature | 0 to +45 ℃ +32 to +113 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉ |
|||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||
Ambient illuminance | Incandescent light: 3,000 lx at the light-receiving face | |||
Voltage withstandability | 500 V AC for one min. between the exclusive controller power input part and the sensor head enclosure | |||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between the exclusive controller power input part and the sensor head enclosure | |||
Vibration resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each |
|||
Shock resistance | 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each |
|||
Emitting element | Red semiconductor laser, Class 3B (Class III b for FDA regulations) (Max. output: 10 mW, Peak emission wavelength: 658 nm 0.026 mil) | Red semiconductor laser, Class 2 (Class II for FDA regulations) (IEC / JIS standards conforming type: IEC / JIS, FDA regulations conforming type: FDA / IEC / JIS) (Max. output: 1 mW, Peak emission wavelength: 658 nm 0.026 mil) |
||
Beam diameter (Note 5) | 400 x 200 μm 15.748 x 7.874 mil approx. | 100 x 140 μm 3.937 x 5.512 mil approx. | 70 x 120 μm 2.756 x 4.724 mil approx. | |
Receiving element | Linear image sensor | |||
Enclosure earthing | Floating | |||
Material | Enclosure: Die-cast aluminum, Case cover: Die-cast aluminum, Front cover: Glass |
|||
Cable | Cabtyre cable, 0.5 m 1.640 ft long with connector | |||
Cable extension | Extension up to total 30 m 98.425 ft is possible, with optional cable. | |||
Weight | Net weight: 300 g approx. | |||
Accessory | Laser warning label JIS(written in Japanese): 1 set (for FDA conforming type only) IEC(written in English)/GB(written in Chinese): 1 set each |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉, sampling rate 100 μs, average number of samples: 256 (HL-C135C-BK10: 512), measurement center distance, object measured is made of white ceramic (an aluminum vapor deposition surface reflection mirror was used with specular reflective type). Linearity also depends upon the characteristics of the object being measured.
2) These values were obtained by converting P-P values into a distance. The P-P values indicate the distribution of measured values throughout the measurement center distance.
3) These values were obtained with an average number of samples: 256 (HL-C135C-BK10: 512), when using an object made of our company's standard white ceramic for measurement (an aluminum vapor deposition surface reflection mirror was used with specular reflective types).
4) This value indicates the range of errors for an ideal linear displacement output, when using an object made of our company's standard white ceramic for measurement (an aluminum vapor deposition surface reflection mirror was used with specular reflective types). This value may fluctuate depending on the characteristics of the object measured.
5) These values were defined by using 1/e2 (13.5 %) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
Type | Specular reflective type | ||
General purpose | High precision | ||
Model No. | IEC / JIS standards conforming type |
HL-C108B | HL-C105B |
FDA regulations conforming type |
HL-C108F | HL-C105F | |
Measurement center distance | 81.4 mm 3.205 in | 46 mm 1.811 in | |
Measuring range | ±16 mm ± 0.630 in | ±4 mm ±0.157 in | |
Resolution (Note 2, 3) | 2 μm 0.079 mil | 1 μm 0.039 mil | |
Linearity (Note 4) | ±0.1 % F.S. | ||
Temperature characteristics | 0.02 % F.S./℃ | ||
Laser emission indicator | Green LED (lights up during laser emission or immediately before laser emission) |
||
Measuring range indicator | Yellow LED [blinks within the measuring range and lights up when near the measurement center distance] |
||
Pollution degree | 3 (Industrial environment) | ||
Protection | IP67 (IEC) (excluding the connector) | ||
Ambient temperature | 0 to +45 ℃ +32 to +113 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉ |
||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Ambient illuminance | Incandescent light: 3,000 lx at the light-receiving face | ||
Voltage withstandability | 500 V AC for one min. between the exclusive controller power input part and the sensor head enclosure | ||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between the exclusive controller power input part and the sensor head enclosure | ||
Vibration resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each |
||
Shock resistance | 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each |
||
Emitting element | Red semiconductor laser, Class 2 (Class II for FDA regulations) (IEC / JIS standards conforming type: IEC / JIS, FDA regulations conforming type: FDA / IEC / JIS) (Max. output: 1 mW, Peak emission wavelength: 658 nm 0.026 mil) |
||
Beam diameter (Note 5) | 100 x 140 μm 3.937 x 5.512 mil approx. | 70 x 120 μm 2.756 x 4.724 mil approx. | |
Receiving element | Linear image sensor | ||
Enclosure earthing | Floating | ||
Material | Enclosure: Die-cast aluminum, Case cover: Die-cast aluminum, Front cover: Glass | ||
Cable | Cabtyre cable, 0.5 m 1.640 ft long with connector | ||
Cable extension | Extension up to total 30 m 98.425 ft is possible, with optional cable. | ||
Weight | Net weight: 300 g approx. | ||
Accessory | Laser warning label JIS(written in Japanese): 1 set (for FDA conforming type only) IEC(written in English)/GB(written in Chinese): 1 set each |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature
+20 ℃ +68 ℉, sampling rate 100 μs, average number of samples: 256, measurement center distance, object measured is made of white ceramic (an aluminum vapor deposition surface reflection mirror was used with specular reflective type). Linearity also depends upon the characteristics of the object being measured.
2) These values were obtained by converting P-P values into a distance. The P-P values indicate the distribution of measured values throughout the measurement center distance.
3) These values were obtained with an average number of samples: 256, when using an object made of our company's standard white ceramic for measurement (an aluminum vapor deposition surface reflection mirror was used with specular reflective types).
4) This value indicates the range of errors for an ideal linear displacement output, when using an object made of our company's standard white ceramic for
measurement (an aluminum vapor deposition surface reflection mirror was used with specular reflective types). This value may fluctuate depending on
the characteristics of the object measured.
5) These values were defined by using 1/e2 (13.5 %) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
Type | Photo-MOS relay output | ||
Stardard | For HL-C135C-BK10 | ||
Model No. | HL-C1C-M | HL-C1C-M-WL | |
Connection sensor heads | Maximum 2 sensor heads | ||
Supply voltage | 24 V DC ± 10 % including ripple 0.5 V (P-P) | ||
Current consumption | When 1 sensor is connected: 430 mA approx., When 2 sensors are connected: 550 mA approx. |
||
Sampling rate | Selectable from 100 μs / 144 μs / 200 μs / 255 μs / 332 μs / 498 μs / 1,000 μs | ||
Temperature characteristics | ±0.01 % F.S./℃ | ||
Analog output | Voltage | Output voltage: ±5 V/F.S. [default setting when diffuse reflective mode is selected (Note 2)] Output range: -10.9 to +10.9 V Output current: Max. 2 mA, Output impedance: 50 Ω |
|
Current (Note 3) | Output current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 4)] Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance) Load impedance: 250 Ω or less |
||
Alarm output | Photo-MOS relay ・Maximum load current: 50 mA ・Applied voltage: 30 V DC or less (between alarm output and COM) ・ON impedance: 35 Ω or less ・Operation time: Max. 2 ms |
||
Output operation | Opened when the amount of light is excessive or insufficient. | ||
Short-circuit protection | Incorporated | ||
Judgment outputs (O1, O2) |
Photo-MOS relay ・Maximum load current: 50 mA ・Applied voltage: 30 V DC or less (between judgment output and COM) ・ON impedance: 35 Ω or less ・Operation time: Max. 2 ms |
||
Utilization category | DC-12 or DC-13 | ||
Output operation | Opened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.) | ||
Short-circuit protection | Incorporated | ||
Serial input / output | RS-232C | ||
Timing input (Laser emission) |
Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection. | - | |
Remote interlock input | - | Laser emission stop when open circuit | |
Zero set ON input | Zero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input |
||
Zero set OFF input | Zero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input |
||
Indicators | Laser emission | Green LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission) |
|
BRIGHT | Red LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2) |
||
DARK | Red LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2) |
||
Setting / Data display | Compact console (optional) | ||
Calibration (Note 5) |
Shift | ±20.0000 mm ±0.787 in | ±200.0000 mm ±7.874 in |
Span | 0.9000 to 1.1000 | ||
Average number of samples (Note 5) |
OFF, 2 to 32,768 times (16 steps) | ||
Digital filters (Note 5) | High pass: OFF, 10 to 2,000 Hz (9 steps), Low pass: OFF, 10 to 2,000 Hz (9 steps) | ||
Calculation functions (Note 5) | L ± KA, L ± KB, L ± K (A ± B) A, B: Sensor head 1, Sensor head 2 measurement values, L = ±999.9999, K = 0.0001 to 99.9999 |
||
Hold functions (Note 5) | Selectable from NORMAL / P-P / PEAK / VALLEY | ||
Pollution degree | 3 (Industrial environment) | ||
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉ |
||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Voltage withstandability | 500 V AC for one min. between power input part and enclosure | ||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between power input part and enclosure | ||
Vibration resistance | 10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each | ||
Shock resistance | 196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each | ||
Cable length | Power line: Less than 10 m 32.808 ft, Signal line: Less than 30 m 98.425 ft | ||
Weight | Net weight: 300 g approx. | ||
Accessory | - | Key: 2 pcs. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature
+20 ℃ + 68 ℉, sampling rate 100 μs, average number of samples: 256 (HL-C1C-M-WL: 512), and measurement center distance.
2) If specular reflective mode is selected, then the default setting is ±4 V/F.S.
3) The maximum analog output current will vary with load impedance.
4) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
5) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Type | Standard | For HL-C1C-M-WL | |
Model No. | HL-C1DP1-E | HL-C1DP1-E-WL | |
Supply voltage | 24 V DC ± 10 % including ripple 0.5 V (P-P) | ||
Current consumption | 200 mA or less | ||
Display | Display element | STN monochrome LCD | |
Back light | White LED | ||
Display range | -999.9999 to 999.9999 | ||
Language | English | ||
Touch panel | Operational force | 0.5 N or less | |
Lifetime | 1,000,000 times or more (Note 1) | ||
Environment resistance | IP65 (at initial status) (Note 2) Dust prevention and drip-proof at the front panel (waterproof packing is used at the contact surface to board) |
||
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ | ||
Ambient humidity | 20 to 85 %RH, Storage: 10 to 85 %RH | ||
Electrostatic noise resistance | 5,000 V or more (panel surface) | ||
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y, and Z directions for 10 min. each | ||
Shock resistance | 98 m/s2 or more acceleration (10G approx.) in X, Y, and Z directions for four times each | ||
Material | Case: PPE, Front protective sheet: Polyester | ||
Weight | 230 g approx. | ||
Accessory | Connector cable for connecting the controller to the console : 1 pc., Mounting bracket: 1 set |
Notes:
1) This value indicates the average lifetime of the unit when used under a normal temperature of 25 ℃ +77 ℉.
2) When reinstalling the console, replace the water proof packing. (Part No: AIGT181, 10 packs included)
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)