Ultra High-speed・High-precision Laser Displacement Sensor HL-C2
Discontinuation plan
|
March 31, 2025 |
|
|
I/O Circuit and Wiring diagrams
Terminal arrangement
|
Terminal |
Function |
NPN |
PNP |
(V)1 |
Analog voltage output (for OUT1) |
AGND |
Analog ground |
(I)1 |
Analog current output (for OUT1) |
(V)2 |
Analog voltage output (for OUT2) |
AGND |
Analog ground |
(I)2 |
Analog current output (for OUT2) |
LSRA |
Laser control input (for Head A) Laser stop during short circuit |
LSRB |
Laser control input (for Head B) Laser stop during short circuit |
(–) |
Common (–) |
IL |
IL- |
Remote interlock Laser stop when opened. |
(–) |
IL+ |
Remote interlock common |
|
|
Terminal |
Function |
NPN |
PNP |
ZS2 |
Zero set input (for OUT2) ON during short circuit (Note 1) |
TM2 |
Timing input (for OUT2) ON during short circuit |
RS2 |
Reset input (for OUT2) ON during short circuit |
(–) |
Common (–) |
AL2 |
Alarm output (for OUT2) |
ST2 |
Strobe output (for OUT2) |
HI2 |
Judgment HI output (for OUT2) |
GO2 |
Judgment GO output (for OUT2) |
LO2 |
Judgment LO output (for OUT2) |
• |
Reserved terminal (Note 2) |
(–) |
(+) |
Common (–) / Common (+) |
M0 |
Memory change (16 ways) |
M1 |
M2 |
M3 |
(–) |
Common (–) |
Notes:
1) |
Turn off the terminal in case short circuit lasts for more than one second. |
2) |
Do not connect anything to the reserved terminals; they are connected to the internal circuit. |
|
|
Terminal |
Function |
NPN |
PNP |
ZS1 |
Zero set input (for OUT1) ON during short circuit (Note 1) |
TM1 |
Timing input (for OUT1) ON during short circuit |
RS1 |
Reset input (for OUT1) ON during short circuit |
• |
Reserved terminal |
• |
Reserved terminal |
(–) |
Common (–) |
AL1 |
Alarm output (for OUT1) |
ST1 |
Strobe output (for OUT1) |
HI1 |
Judgment HI output (for OUT1) |
GO1 |
Judgment GO output (for OUT1) |
LO1 |
Judgment LO output (for OUT1) |
• |
Reserved terminal (Note 2) |
(–) |
(+) |
Common (–) / Common (+) |
24V |
24 V DC input for power supply |
0V |
Power supply ground 0 V |
FG |
Frame ground |
Notes:
1) |
Turn off the terminal in case short circuit lasts for more than one second. |
2) |
Do not connect anything to the reserved terminals; they are connected to the internal circuit. |
|
NPN output type
No voltage input or NPN transistor open
collector output |
|
|
|
Non-voltage
input |
|
|
PNP output type
No voltage input or NPN transistor open
collector output |
|
|
|
Non-voltage
input |
|
|
Analog output (Common in NPN output type and PNP output type)
Notes: 1) Do not short-circuit analog output terminals or apply voltage to them.
2) Use shielded wires for analog outputs.
Return to top