Type | Red LED | Blue LED | Green LED | |
---|---|---|---|---|
Model No. | NPN output | FX-311 | FX-311B | FX-311G |
PNP output | FX-311P | FX-311BP | FX-311GP | |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | |||
Power consumption | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | |||
Output | <NPN open-collector transistor> • Maximum sink current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] <PNP open-collector transistor> • Maximum source current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less [at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] |
|||
Utilization category |
DC-12 or DC-13 | |||
Output operation |
Selectable either Light-ON or Dark-ON, with selection switch | |||
Short-circuit protection |
Incorporated | |||
Response time | <Red LED type> 250 μs or less (STD / S-D), 2 ms or less (LONG) selectable with selection switch <Blue LED type / Green LED type> 150 μs or less (FAST), 250 μs or less (STD), 2 ms or less (LONG) selectable with selection switch |
|||
Operation indicator | Orange LED (lights up when the output is ON) | |||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) | |||
Sensitivity adjuster | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note 2) | |||
Timer function | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | |||
Automatic interference prevention function |
Incorporated (Up to 4 sets of fiber heads can be mounted close together.) (Note 3) | |||
Pollution degree | 3 (Industrial environment) | |||
Ambient temperature | -10 to +55 ℃ -14 to +131 ℉ (If 4 to 7 units are connected in cascade: -10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
|||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||
Ambient illuminance | Incandescent light: 3,000 ℓx at the light-receiving face | |||
EMC | EN 60947-5-2 | |||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 4) | |||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 4) | |||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.03 in amplitude in X, Y and Z directions for two hours each | |||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each | |||
Emitting element (modulated) |
Red LED | Blue LED | Green LED | |
Peak emission wavelength |
650 nm 0.026 mil |
470 nm 0.019 mil |
525 nm 0.021 mil |
|
Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate | |||
Connecting method | Connector (Note 5) | |||
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | |||
Weight | Net weight: 15 g approx., Gross weight: 20 g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2) | The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. |
3) | When the power supply is switched on, the emission timing are automatically set for interference prevention. |
4) | The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
5) | The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below. Main cable (3-core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft) Sub cable (1-core): CN-71-C1 (cable length 1 m 3.281 ft), CN-71-C2 (cable length 2 m 6.562 ft), CN-71-C5 (cable length 5 m 16.404 ft) |