Compact Photoelectric Sensor CX-400 Ver.2

Sensing characteristics

*TYPICAL

CX-411□

Thru-beam type

Parallel deviation

CX-411□ Parallel deviation

Angular deviation

CX-411□ Angular deviation

Parallel deviation with round slit masks
(ø0.5 mm ø0.020 in)

CX-411□ Parallel deviation with round slit masks(ø 0.5 mmø 0.020 in)

Parallel deviation with round slit masks
(ø1 mm ø0.039 in)

CX-411□ Parallel deviation with round slit masks(ø1 mm ø0.039 in)

Parallel deviation with round slit masks
(ø2 mm ø0.079 in)

CX-411□ Parallel deviation with round slit masks(ø2 mm ø0.079 in)

Parallel deviation with rectangular slit masks
(0.5 × 6 mm 0.020 × 0.236 in)

CX-411□ Parallel deviation with rectangular slit masks(0.5 × 6 mm 0.020 × 0.236 in)

Parallel deviation with rectangular slit masks
(1 × 6 mm 0.039 × 0.236 in)

CX-411□ Parallel deviation with rectangular slit masks(1 × 6 mm 0.039 × 0.236 in)

Parallel deviation with rectangular slit masks
(2 × 6 mm 0.079 × 0.236 in)

CX-411□ Parallel deviation with rectangular slit masks (2 × 6 mm 0.079 × 0.236 in)

CX-412□

Thru-beam type

Parallel deviation

CX-412□ Parallel deviation

Angular deviation

CX-412□ Angular deviation

Parallel deviation with round slit masks
(ø0.5 mm ø0.020 in)

CX-412□ Parallel deviation with round slit masks (ø0.5 mm ø0.020 in)

Parallel deviation with round slit masks
(ø1 mm ø0.039 in)

CX-412□ Parallel deviation with round slit masks (ø1 mm ø0.039 in)

Parallel deviation with round slit masks
(ø2 mm ø0.079 in)

CX-412□ Parallel deviation with round slit masks (ø2 mm ø0.079 in)

Parallel deviation with rectangular slit masks
(0.5 × 6 mm 0.020 × 0.236 in)

CX-412□ Parallel deviation with rectangular slit masks(0.5 × 6 mm 0.020 × 0.236 in)

Parallel deviation with rectangular slit masks
(1 × 6 mm 0.039 × 0.236 in)

CX-412□ Parallel deviation with rectangular slit masks (1 × 6 mm 0.039 × 0.236 in)

Parallel deviation with rectangular slit masks
(2 × 6 mm 0.079 × 0.236 in)

CX-412□ Parallel deviation with rectangular slit masks (2 × 6 mm 0.079 × 0.236 in)

CX-491□

Retroreflective type

Parallel deviation

CX-491□ Parallel deviation

Angular deviation

CX-491□ Angular deviation

CX-493□

Retroreflective type

Parallel deviation

CX-493□ Parallel deviation

Angular deviation

CX-493□ Angular deviation

CX-481□

Retroreflective type

Parallel deviation

CX-481□ Parallel deviation

Angular deviation

CX-481□ Angular deviation

CX-482□

Retroreflective type

Parallel deviation

CX-482□ Parallel deviation

Angular deviation

CX-482□ Angular deviation

CX-424□

Diffuse reflective type

Sensing field

CX-424□ Sensing field

Correlation between sensing object size and sensing range

CX-424□ Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph.
(For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 100 mm 3.937 in.)

CX-421□

Diffuse reflective type

Sensing field


CX-421□ Sensing field

Correlation between sensing object size and sensing range

CX-421□ Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph.
(For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 300 mm 11.811 in.)

CX-422□

Diffuse reflective type

Sensing field


CX-422□ Sensing field

Correlation between sensing object size and sensing range

CX-422□ Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph.
(For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 800 mm 31.496 in.)

CX-423□

Diffuse reflective type

Sensing field


CX-423□ Sensing field

Correlation between sensing object size and sensing range

CX-423□ Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (white non-glossy paper 200 × 200 mm 7.874 × 7.874 in), the sensing range shortens, as shown in the left graph.
(For plotting the left graph, the sensitivity has been set such that a 200 × 200 mm 7.874 × 7.874 in white non-glossy paper is just detectable at a distance of 200 mm 7.874 in. Contact us for the sensing characteristics of 300 mm 11.811 in distance. Please contact us for the sensing field at the setting distance 300 mm 11.811 in.)


Correlation between lightness and sensing range

CX-423□ Correlation between lightness and sensing range

The sensing region is represented by oblique lines in the left figure.
However, the sensitivity should be set with an enough margin because of slight variation in products.

(Lightness shown on the left may differ slightly from the actual object condition.)


Emitted beam

CX-423□ Emitted beam

CX-441□

Adjustable range reflective type

Sensing fields
・Setting distance: 25 mm 0.984 in

CX-441□ Sensing fields Setting distance: 25 mm 0.984 in

・Setting distance: 50 mm 1.969 in

CX-441□ Setting distance: 50 mm 1.969 in

Emitted beam

CX-441□ Emitted beam

Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

CX-441□ Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white color.
The sensing range also varies depending on material.


Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range

CX-441□ Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range

These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white non-glossy paper.

CX-443□ (Discontinued products)

Adjustable range reflective type

Sensing fields
・Setting distance: 25 mm 0.984 in

CX-443□ Sensing fields Setting distance: 25 mm 0.984 in

・Setting distance: 50 mm 1.969 in

CX-443□ Sensing fields Setting distance: 50 mm 1.969 in

Emitted beam


CX-443□ Emitted beam

Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

CX-443□ Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white color.
The sensing range also varies depending on material.


Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range

CX-443□ Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range

These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 50 mm 1.969 in and 25 mm 0.984 in long, respectively, with white non-glossy paper.

CX-444□

Adjustable range reflective type

Sensing fields
・Setting distance: 25 mm 0.984 in

CX-444□ Sensing fields Setting distance: 25 mm 0.984 in

・Setting distance: 50 mm 1.969 in

CX-444□ Sensing fields Setting distance: 50 mm 1.969 in

・Setting distance: 100 mm 3.937 in

CX-444□ Sensing fields Setting distance: 100 mm 3.937 in

Emitted beam

CX-444□ Emitted beam

Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

CX-444□ Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 100 mm 3.937 in and 50 mm 1.969 in long, respectively, with white color.
The sensing range also varies depending on material.


Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range

CX-444□ Correlation between material(50 × 50 mm 1.969 × 1.969 in) and sensing range

These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 100 mm 3.937 in and 50 mm 1.969 in long, respectively, with white non-glossy paper.

CX-442□

Adjustable range reflective type

Sensing fields
・Setting distance: 100 mm 3.937 in

CX-442□ Sensing fields Setting distance: 100 mm 3.937 in

・Setting distance: 200 mm 7.874 in

CX-442□ Sensing fields Setting distance: 200 mm 7.874 in

・Setting distance: 300 mm 11.811 in

CX-442□ Sensing fields Setting distance: 300 mm 11.811 in

Emitted beam

CX-442□ Emitted beam

Correlation between color
(50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

CX-442□ Correlation between color (50 × 50 mm 1.969 × 1.969 in construction paper) and sensing range

These bars indicate the sensing range with the respective colors when the distance adjuster is set to a sensing range of 300 mm 11.811 in, 200 mm 7.874 in and 100 mm 3.937 in long, respectively, with white color.
The sensing range also varies depending on material.


Correlation between material
(50 × 50 mm 1.969 × 1.969 in) and sensing range

CX-442□ Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range

These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 300 mm 11.811 in, 200 mm 7.874 in and 100 mm 3.937 in long, respectively, with white non-glossy paper.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)