> CMOS type Micro Laser Distance Sensor HG-C
|
Reliable detection in repeatability 10 μm 0.394 mil*
* HG-C1030□
|
![]() |
![]() |
![]() |
UL/C-UL
, CE
, FDA
Approved
* This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
|
The value can be measured with a distance measurement sensor.
・ Linearity:±0.1%F.S.*1
・ Temperature characteristics:0.03 %F.S./℃
*1 : HG-C1030(-P)/HG-C1050(-P)/HG-C1100(-P)
![]() |
*Based on research conducted by our company as of July 2022
A new optical system with a built-in mirror |
![]() |
An aluminum die-cast casing protects from strain and heat |
![]() |
* HG-C1030□
Fitted with a precise CMOS image sensor and an original algorithm |
![]() |
Normal sensing mode
[2-Point teaching]
Basic teaching method
|
[Limit teaching]
Useful teaching method for when there is a very small object or background object.
|
|
Window comparator mode
With an object below the sensor, press the TEACH key to set the valid range for distances via threshold values. There are 3 methods for setting the valid range: 1-point, 2-point, and 3-point teaching.
![]() |
|
![]() |
|
![]() |
|
Rising differential mode / Trailing differential mode
Use this mode to cancel gradual changes in the measured value and to detect only sudden changes. For the setting of threshold value, use the threshold value fine adjustment function.
The time mode options are “off-delay timer,” “on-delay timer,” “one-shot timer” and “no timer.” The counting time is fixed to 5 ms.
![]() Timer period: 5 ms (fixed) |
Off-delay timer |
|
|
|
The peak hold function holds the maximum measured value which is output and displayed.
The bottom hold function holds the minimum measured value which is output and displayed.
* The peak hold function and the bottom hold function cannot be set at the same time.
* When the zero set function is executed while the peak hold function or the bottom hold function is valid, the held measurement value is reset.
Fine adjustment of threshold values can be performed while measurement is proceeding on the display, and even after teaching.
This function protects setting conditions from unintentional changes.
* For other functions and procedures for setting the functions, see the instruction manual provided with the product.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)