【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



CMOS Type Micro Laser Distance Sensor HG-C1000L

Specifications

Type Measurement center
30 mm
1.181 in type
Measurement center
50 mm
1.969 in type
Measurement center
100 mm
3.937 in type
Measurement center
200 mm
7.874 in type
Measurement center
400 mm
15.748 in type
Model No. Discrete wire HG-C1030L3-P HG-C1050L3-P HG-C1100L3-P HG-C1200L3-P HG-C1400L3-P
M12 connector HG-C1030L3-P-J HG-C1050L3-P-J HG-C1100L3-P-J HG-C1200L3-P-J HG-C1400L3-P-J
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification
Measurement center distance 30mm
1.181 in
50mm
1.969 in
100mm
3.937 in
200mm
7.874 in
400mm
15.748 in
Measurement range ±5mm
0.197 in
±15mm
0.591 in
±35mm
1.328 in
±80mm
3.150 in
±200mm
7.874 in
Repeatability 10μm
0.394 mil
30μm
1.181 mil
70μm
2.756 mil
200μm
7.874 mil
300μm
11.811 mil
(Measuring distance 200~400mm 7.874 to 15.748 in)
800μm
(Measuring distance 400~600mm 15.748 to 23.622 in)
Linearity ±0.1%F.S. ±0.2%F.S. ±0.2%F.S.
(Measuring distance 200~400mm 7.874 to 15.748 in)
±0.3%F.S.
(Measuring distance 400~600mm 15.748 to 23.622 in)
Temperature characteristic 0.03%F.S./℃
Light source Red semiconductor laser Class 2 [IEC / EN/ JIS / GB / KS / FDA (Note 2)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil
Beam diameter (Note 3) ø50μm
1.969 mil approx
ø70μm
2.756 mil approx
ø120μm
4.724 mil approx
ø300μm
11.811 mil approx
ø500μm
19.685 mil approx
Supply voltage 24V DC±10% Ripple P-P10%
Power consumption 40 mA or less (at 24 V DC supply voltage)
Communication
output (C/Q)
(Note 4)
IO-Link communication IO-Link Specification V1.1
Baud rate COM3(230.4kbps)
Process data 4byte
Minimum cycle time 1.0ms
Control output (DO) PNP open-collector transistor
•Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to +V)
• Residual voltage: 1.5 V or less (at 50 mA source current)
• Leakage current: 0.1 mA or less
  Output operation Switchable between either Light-ON or Dark-ON
Short-circuit protection Incorporated (auto reset type)
Response time Switchable between 1.5 ms / 5 ms / 10 ms
Pollution degree 2
Ambient altitude 2,000 m 6561.680 ft or less
Environmental resistance Protection IP67(IEC)
Ambient temperature -10~+45℃ -14 to 113℉(No dew condensation or icing allowed)、Storage:-20~+60℃ -4 to 140℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Cable Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long
M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long
Cable extension Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable.
Material Enclosure: Aluminum die-cast, Front cover: Acrylic
Weight Discrete wire type: 30 g approx. (without cable), 80 g approx. (including cable)
M12 connector type: 30 g approx. (without cable), 50 g approx. (including cable)

Notes: 1) Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
2) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
3) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
4) When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)