【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



Robust Photoelectric Sensor RX (Discontinued Products)

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Wiring

  • The self-diagnosis output does not incorporate a shortcircuit protection circuit. Do not connect it directly to a power supply or a capacitive load.

Mounting

  • The tightening torque should be 1.17 N·m or less.

Mounting

Others

  • Do not use during the initial transient time (50 ms) after the power supply is switched on.

RX-RVM5
Glossy object sensing

  • Please take care of the following points when detecting materials having a gloss.

[1] Make L, shown in the diagram, sufficiently long.
[2] Install at an angle of 10 to 30 degrees to the sensing object.

Glossy object sensing

RX-PRVM3 RX2-PRVM2
Retroreflective type sensor with polarizing filters

  • If a shiny object is covered or wrapped with a transparent film such as those described below, the retroreflective type sensor with polarizing filters may not be able to detect it.
    In that case, follow the steps given below.

Example of sensing objects

  • Can wrapped by clear film
  • Aluminum sheet covered by plastic film
  • Gold or silver color (specular) label or wrapping paper

Steps

  • Tilt the sensor with respect to the sensing object while fitting.
  • Reduce the sensitivity.
  • Increase the distance between the sensor and the sensing object.

RX2-□
Wiring

  • Always connect the sensor to the power supply through a load. If the sensor is connected to the power supply directly, the short-circuit protection makes the sensor inoperable. (The output stays in the OFF state and no indicator lights up.) If this happens, connect the sensor to the power supply through a load.
    Further, note that the sensor will be damaged if the power supply is connected in reverse without a load.

Wiring

  • Do not connect sensors in series (AND circuit).

Do not connect sensors in series (AND circuit).

  • The residual voltage of the sensor is 4 V. Before connecting to a relay, be aware of the actuation voltage of the relay.
    (Not all 12 V relays may be connected as the load.)

RX4-□
Connection of protective tube connector

  • Connect the junction connector securely as shown below. The tightening torque should be 0.98 N·m or less.

When mounted on a plate

When mounted on a plate

When mounted with a female screw

When mounted with a female screw

When connected to another protective tube

When connected to another protective tube

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)