Type | Thru-beam | Retroreflective | ||||
---|---|---|---|---|---|---|
With timer | With timer | With polarizing filters |
||||
Model No. | VF-M10 | VF-M10T | VF-RM5 | VF-RM5T | VF-PRM3 | |
Sensing range | 10 m 32.808 ft | 0.1 to 5 m 0.328 to 16.404 ft (Note 2) |
0.2 to 3 m 0.656 to 9.843 ft (Note 2) |
|||
Sensing object | ø20 mm ø0.787 in or more opaque object (Note 4) |
ø50 mm ø1.969 in or more opaque or translucent object (Note 2, 5) |
ø50 mm ø1.969 in
or more opaque, translucent or specular object (Note 2, 5) |
|||
Hysteresis | - | |||||
Supply voltage | 24 to 240 V AC +10-15% or 12 to 240 V DC +10–15% | |||||
Power consumption | Emitter: 3 VA or less (Average: 1.5 W or less) Receiver: 3 VA or less (Average: 1.5 W or less) |
3 VA or less (Average: 1.5 W or less) | ||||
Output | Relay contact 1a ・Switching capacity: 250 V 1 A AC (resistive load), 30 V 2 A DC (resistive load) ・Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) ・Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
|||||
Output operation | Switchable either Light-ON or Dark-ON | |||||
Response time | 20 ms or less | |||||
Operation indicator | Red LED (lights up when the output is ON) | |||||
Sensitivity adjuster | - | |||||
Timer function (0.1 to 5 sec. variable) |
- | Selectable from ONdelay, OFF-delay & ONE SHOT |
- | Selectable from ONdelay, OFF-delay & ONE SHOT |
- | |
Pollution degree | 3 (Industrial environment) | |||||
Protection | IP66 (IEC) | |||||
Ambient temperature | –10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ |
|||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||||
Ambient illuminance | Incandescent light: 3,500 Lx at the light-receiving face | |||||
EMC | EN 61000-6-2, EN 61000-6-4 | |||||
Voltage withstandability | 1,500 V AC for one min. between the power supply and output terminals, 1,000 V AC for one min. between the relay contact terminals | |||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between the power supply and output terminals, and between the relay contact terminals | |||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | |||||
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each | |||||
Emitting element (modulated) |
Infrared LED | Red LED | ||||
Peak emission wavelength |
950 nm 0.037 mil | 660 nm 0.026 mil | ||||
Material | Enclosure: PBT, Lens: Acrylic (front surface of VF-PRM3: Triacetate) | |||||
Connection method | Screw-on terminal connection | |||||
Cable | Suitable for round cable ø6 to ø10 mm ø0.236 to ø0.394 in (Conductor cross-section area: 0.25 to 0.75 mm2). |
|||||
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable (thru-beam type: both emitter and receiver). |
|||||
Net weight | Emitter: 75 g approx. Receiver: 95 g approx. |
95 g approx. | ||||
Accessories | MS-N70 (Sensor mounting bracket): 1 set, Gland and gland washer: 1 set, Gland packing (large / small 1 pc. each): 1 set VF-SKG (Short-circuit metal joint): 1 pc., RF-230 (Reflector): 1 pc. for the retroreflective type sensor Adjusting screwdriver: 1 pc. for the diffuse reflective type sensor and for sensors with timer functions (suffixed with "T") (2 sets of sensor mounting bracket, gland, gland washer and gland packing are attached for the thru-beam type sensors.) |
Type | Diffuse reflective | ||||
---|---|---|---|---|---|
With timer | With timer | ||||
Model No. | VF-D500 | VF-D500T | VF-D1000 | VF-D1000T | |
Sensing range | 500 mm 19.685 in (Note 3) | 1 m 3.281 ft (Note 3) | |||
Sensing object | Opaque, translucent or transparent object (Note 5) | ||||
Hysteresis | 15 % or less of operation distance (Note 3) | ||||
Supply voltage | 24 to 240 V AC +10-15% or 12 to 240 V DC +10–15% | ||||
Power consumption | 3 VA or less (Average: 1.5 W or less) | ||||
Output | Relay contact 1a ・Switching capacity: 250 V 1 A AC (resistive load), 30 V 2 A DC (resistive load) ・Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) ・Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
||||
Output operation | Switchable either Light-ON or Dark-ON | ||||
Response time | 20 ms or less | ||||
Operation indicator | Red LED (lights up when the output is ON) | ||||
Sensitivity adjuster | Continuously variable adjuster | ||||
Timer function (0.1 to 5 sec. variable) |
- | Selectable from ONdelay, OFF-delay & ONE SHOT |
- | Selectable from ONdelay, OFF-delay & ONE SHOT |
|
Pollution degree | 3 (Industrial environment) | ||||
Protection | IP66 (IEC) | ||||
Ambient temperature | –10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 3,500 Lx at the light-receiving face | ||||
EMC | EN 61000-6-2, EN 61000-6-4 | ||||
Voltage withstandability | 1,500 V AC for one min. between the power supply and output terminals, 1,000 V AC for one min. between the relay contact terminals | ||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between the power supply and output terminals, and between the relay contact terminals | ||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each | ||||
Emitting element (modulated) |
Infrared LED | ||||
Peak emission wavelength |
950 nm 0.037 mil | ||||
Material | Enclosure: PBT, Lens: Acrylic | ||||
Connection method | Screw-on terminal connection | ||||
Cable | Suitable for round cable ø6 to ø10 mm ø0.236 to ø0.394 in (Conductor cross-section area: 0.25 to 0.75 mm2). |
||||
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable | ||||
Net weight | 95 g approx. | ||||
Accessories | MS-N70 (Sensor mounting bracket): 1 set, Gland and gland washer: 1 set, Gland packing (large / small 1 pc. each): 1 set VF-SKG (Short-circuit metal joint): 1 pc., Adjusting screwdriver: 1 pc. for the diffuse reflective type sensor and for sensors with timer functions (suffixed with "T") |
note 1 : | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
note 2 : | The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft (VF-PRM3: 0.2 m 0.656 ft) away. |
note 3 : | The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
note 4 : | If slit masks (optional) are fitted, even an object of 3 x 6 mm 0.118 x 0.236 in can be detected. |
note 5 : | Make sure to confirm detection with an actual sensor before use. |
|