【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Inductive Proximity Sensors > Compact Micro-size Inductive Proximity Sensor GS/GA(Discontinued Products) > Specifications
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
Type | Non-threaded type | Front sensing type |
||
---|---|---|---|---|
Model No. | GS-3S | GS-5S | GS-8S | GS-14T |
Applicable amplifiers | GA-2, GA-2R, GA-2D | |||
Max. operation distance (Note 2) | 2 mm 0.079 in | 3 mm 0.118 in | 4 mm 0.157 in | 8 mm 0.315 in |
Stable sensing range (Note 2) | 0 to 0.8 mm 0 to 0.031 in |
0 to 1mm 0 to 0.039 in |
0 to 2 mm 0 to 0.079 in |
0 to 5 mm 0 to 0.197 in |
Standard sensing object | Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in | |||
Hysteresis | 50 μm 1.969 mil or less | 70 μm 2.756 mil or less | ||
Repeatability (Note 3) | 2 μm 0.079 mil or less |
2.5 μm 0.098 mil or less |
5 μm 0.197 mil or less |
5 μm 0.197 mil or less |
Protection | IP67 (IEC) | |||
Ambient temperature | –10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉ | |||
Ambient humidity | 35 to 95 % RH, Storage: 35 to 95 % RH | |||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | |||
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | |||
Material | Enclosure: Stainless steel [threaded type sensor head: Brass (Nickel plated)], Resin part: PVC | |||
Cable | Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note 4) | |||
Cable extension | Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note 4) | |||
Net weight (Note 5) | 35 g approx. | 36 g approx. | 37 g approx. | 46 g approx. |
Accessories | - |
Type | Threaded type | |||
---|---|---|---|---|
Model No. | GS-8M | GS-10M | GS-12M | GS-14M |
Applicable amplifiers | GA-2, GA-2R, GA-2D | |||
Max. operation distance (Note 2) | 3.5 mm 0.138 in | 4 mm 0.157 in | 6 mm 0.236 in | 8 mm 0.315 in |
Stable sensing range (Note 2) | 0 to 1.5 mm 0 to 0.059 in |
0 to 2mm 0 to 0.079 in |
0 to 3 mm 0 to 0.118 in |
0 to 5 mm 0 to 0.197 in |
Standard sensing object | Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in | |||
Hysteresis | 50 μm 1.969 mil or less | 60 μm 2.362 mil or less | 70 μm 2.756 mil or less | |
Repeatability (Note 3) | 3μm 0.118 mil or less |
5 μm 0.197 mil or less |
||
Protection | IP67 (IEC) | |||
Ambient temperature | –10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉ | |||
Ambient humidity | 35 to 95 % RH, Storage: 35 to 95 % RH | |||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | |||
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | |||
Material | Enclosure: Stainless steel [threaded type sensor head: Brass (Nickel plated)], Resin part: PVC | |||
Cable | Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note 4) | |||
Cable extension | Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note 4) | |||
Net weight (Note 5) | 44 g approx. | 45 g approx. | 50 g approx. | 53 g approx. |
Accessories | Nut: 2 pcs., Toothed lock washer: 1 pc. |
Note 1 : | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
Note 2 : | The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
Note 3 : | The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis) |
Note 4 : | If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change. |
Note 5 : | The weight of the threaded type includes the weight of two nuts and one toothed lock washer. |
Type | AC supply type | DC supply type | ||
---|---|---|---|---|
Model No. | GA-2 | GA-2R | GA-2D | |
Supply voltage | 90 to 260 V AC | 10 to 28 V DC | ||
Power / current consumption | 2.5 VA approx. | 9 VA approx. | 20 mA approx. | |
Output | AC non-contact (Photo-thyristor) ・Switching capacity: 260V AC 2 to 100 mA |
Relay contact 1a ・Switching capacity: 250V AC 2A (resistive load) ・Rated load life: 500,000 or more switching operations |
NPN open-collector transistor • Maximum sink current: 200 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (at 200 mA sink current) 0.4 V or less (at 16 mA sink current) • Short-circuit protection PNP open-collector transistor • Maximum source current: 200 mA • Residual voltage: 1.5 V or less (at 200 mA source current) • Short-circuit protection |
|
Output operation | Selectable either Normally open or Normally closed | |||
Response time | 10 ms or less | 1 ms or less | ||
Operation indicator | Red LED (lights up when the output is ON) | |||
Sensitivity adjuster | 15-turn potentiometer | |||
Ambient temperature | -10 to +60 ℃ -14 to +140 ℉ (No dew condensation or icing allowed), Storage: -10 to +60 ℃ -14 to +140 ℉ |
|||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||
Material | Cover: ABS, Terminal part: PBT | |||
Net weight | 130 g approx. | 150 g approx. | 75 g approx. | |
Accessory | Adjusting screwdriver: 1 pc. |
Note : | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)