Safety Control Unit SF-C21

Creating safety circuits is easier than ever!

CE Marking UKCA TUV SUD  TUV SUD

UL , CE , CSA , TUV , UKCA Approved
UL, CSA : Certified by TÜV SÜD America Inc.

Category 4 PLe SILCL3 JIS

The control category differs depending on the configuration and wiring of the external circuit.

Features

Finding space to install and wire is easy

One SF-C21 can do the work of four safety relay units.
Simple to wire the units in the control panel!!

One SF-C21 can do the work of four safety relay units. Simple to wire the units in the control panel!!

Small, so the unit can be installed in a narrow space
Compact with a height 97 mm 3.819 in × width 45 mm 1.772 in.
It's easy to find installation space for the SF-C21 unit.

Long-life semiconductor output (PNP) adopted for control output and auxiliary output

Small, so the unit can be installed in a narrow space

Easy to monitor status with a generalpurpose PLC
Four auxiliary outputs (PNP semiconductor output) are provided.
Using RS-485 communications (MODBUS RTU), various general-purpose control units (PLC, HMI, etc.) can monitor the SF-C21 information such as the status, the selected logic, and any error status.

Easy to monitor status with a generalpurpose PLC

Note: Communication information can not be used for safety control.

Absolutely no programming skills required.
Operation is easy - just select a preset logic

Simply turn a switch to set
Eight preset logics, safety-certified and compatible up to control category 4 PLe, can be selected by simply turning the rotary switch.

8 preset logics
*The logic customized by user can be stored in the logic No. 0.
Simply turn a switch to set

Refer to " 8 preset logics"

Easy to set the "OFF delay"
The OFF delay time can be easily set by simply turning the rotary switch to any one of patterns.

Pattern No. 0 1 2 3 4 5 6 7 8 9
OFF delay time (sec.) 0 0.1 0.5 1 2 5 10 15 30 60

* The OFF delay time applies to control output 2. In case of setting the OFF delay time to control output 1, the "Configurator SF-C" software is needed.

Password protection prevents inadvertent logic changes

Application-based customization is easy

Easy to create a reliable safety circuit Use our "Configurator SF-C" software to build your own safety circuits of connected devices, control logic, output modes, etc. No programming skills required!

Customized logics are safety-certified too!!
All possible logic combinations created with the "Configurator SF-C" software are already safety-certified by the certification bodies. The software also has a "simulation mode" to test if the prepared logic and safety circuit operates as intended. If the logic is not complete, the software will block its transfer to the SF-C21 unit.

Note:
Please read the instruction manual in advance when selecting or creating logics, and verify whether the combination of connecting devices and logics complies with each machine safety standard.

Configurator SF-C

8 preset logics compatible up to control category 4, PLe standards

Note:
Please make sure that the combination of logics and input devices complies with each machine safety standard.

Logic No.1:Overall stop control

Overall stop control

When any connected input becomes OFF, the entire control output will be OFF.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.2:Parallel muting control

Parallel muting control

When the muting input becomes ON, the safety light curtain will be temporarily disabled.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.3:Sequential muting control

Sequential muting control

Only when the muting input becomes ON following a predefined sequence, the safety light curtain will
be temporarily disabled.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.4:Partial stop control 1

Partial stop control 1

When the emergency stop input is OFF, the entire control output will be OFF. When any other input is OFF, its corresponding control output will be OFF.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.5:Partial stop control 2

Partial stop control 2

When the emergency stop input or the input from the back-end process becomes OFF, the entire control output will be OFF. When the input from the front-end process becomes OFF, only its corresponding control output will be OFF.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.6:Two-hand control

Two-hand control

This control is applied when a two-hand operation switch is used for control.Only when both switches of the two-hand operation switch are operated within 0.5 sec., control output will be ON.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.7:OR control

OR control

Even when the guard (input A) is OFF, if the enabling switch is ON the control output will be ON. If either the emergency switch or input B becomes OFF, the entire control output will be OFF regardless of the status of the input A and emergency switch.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Logic No.8:Operation mode selection control

Only when mode selection using the key selector is followed by the enabling switch being turned ON, the control output will be ON regardless of the open / close status of the guard.
Note that if the emergency stop switch is OFF, the entire control output will be OFF.

*1 The delay time can be set using the Configurator SF-C.
*2 The initial OFF delay is set to 0 seconds.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)