AUTOMATION
CONTROLS

Search
Discontinued
Products



Ultra-slim Light Curtain [Type 2 PLc SIL1] SF2C

I/O Circuit and Wiring diagrams

PNP output type

PNP output type I/O circuit diagram
  • S1,S2
Switch S1
Test input / Large multi-purpose indicator input
ON : Vs –2.5 V to Vs
OFF : Open
Switch S2
Frequency setting input
Frequency 1 setting: Open
Frequency 2 setting: +V

Notes:

1) If the large multi-purpose indicator input wiring (Orange) is connected to +V, the orange LED lights on. When they are disconnected, the orange LED lights off.
2) Vs is the applying supply voltage.

NPN output type

NPN output type I/O circuit diagram
  • S1,S2
Switch S1
Test input / Large multi-purpose indicator input
ON : 0 to +2.5 V
OFF : Open
Switch S2
Frequency setting input
Frequency 1 setting: Open
Frequency 2 setting: +V

Note:

If the large multi-purpose indicator input wiring (Orange) is connected to 0V, the orange LED lights on. When they are disconnected, the orange LED lights off.

Connection example

Basic wiring: Min. operation only

This is the general configuration using one set of the emitter and receiver facing each other. The control output (OSSD) turns OFF if the light is interrupted, while it automatically turns ON if receive the light.

<PNP output type SF2C-H□-P>

Connection example Basic wiring: Min. operation only PNP output type SF2C-H□-P

<NPN output type SF2C-H□-N>

Connection example Basic wiring: Min. operation only NPN output type SF2C-H□-N

Wiring in case of using test input / large multi-purpose indicator / interference prevention functions

<PNP output type SF2C-H□-P>

Connection example Wiring in case of using test input / large multi-purpose indicator / interference prevention functions PNP output type SF2C-H□-P

・S1

    

<Frequency setting input>

Switch S1
     ON: Vs –2.5 V to Vs
OFF: Open
    
Frequency 1 setting: Open
Frequency 2 setting: +V

Notes:

1) If the large multi-purpose indicator input wiring (Orange) is connected to +V, the orange LED lights on. When they are disconnected, the orange LED lights off.
2) Vs is the applying supply voltage.

<NPN output type SF2C-H□-N>

Connection example Wiring in case of using test input / large multi-purpose indicator / interference prevention functions NPN output type SF2C-H□-N

・S1

    

<Frequency setting input>

Switch S1
     ON: 0 to +2.5 V
OFF: Open
    
Frequency 1 setting: Open
Frequency 2 setting: +V

Note:

If the large multi-purpose indicator input wiring (Orange) is connected to 0V, the orange LED lights on. When they are disconnected, the orange LED lights off.

Control unit SF-C13 wiring diagram (Control category 2)

PNP output type: Min. operation only

Connect the safety light curtain control output OSSD to S1 and make a short-circuit between S2 and S3.

Control unit SF-C13 wiring diagram (Control category 2) PNP output type: Min. operation only

Notes:

1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.

NPN output type: Min. operation only

Connect the safety light curtain control output OSSD to S4 and make a short-circuit between S2 and S3.

Control unit SF-C13 wiring diagram (Control category 2) NPN output type: Min. operation only

Notes:

1) The left diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.

Terminal arrangement diagram

Terminal arrangement diagram     
Terminal Function
A1 +24 V DC
A2 0 V
S1 to S4 Safety light curtain control output
(OSSD) input terminal
AUX Semiconductor auxiliary output
X1 Reset output terminal
X2 Reset input terminal (Manual)
X3 Reset input terminal (Automatic)
13-14, 23-24, 33-34 Safety output (NO contact × 3)
41-42 Auxiliary output (NC contact × 1)
A terminal block is required for wiring of safety light curtain side.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)