【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



Compact Type 4 Safety Beam Sensor ST4

From wide areas to narrow spaces, full support for both safety and productivity!

Compact Type 4 Safety Beam Sensor ST4
C-UL-US CE Marking UKCA TUV SUD

UL/C-UL , CE , TUV , UKCA Approved
CE :Machinery Directive, EMC Directive
UKCA :Machinery Regulations, EMC Regulations
UL : Approved Listing

OSHA/ANSI JIS Category 4 PLe SIL3※1
※1The control category differs depending on the configuration and wiring of the external circuit.

Features

Long sensing range of up to 15 m 49.213 ft [Sensor head]

Secures safety of large facilities where installation of guardian fence is difficult.

Long sensing range of up to 15 m 49.213 ft

Series connection of sensors and interference prevention [Sensor head]

The numbers of sensor heads and controllers can be freely adjusted to meet the heights and the required numbers of the protection area.

Series connection of sensors and interference prevention [Sensor head]

Beam axis alignment and operation confirmation [Sensor head]

The beam interruption indicator is incorporated in both the emitter and receiver. This indicator can be used not only for operation confirmation but also for beam axis alignment. Moreover, the stability indicator indicates if the incident light intensity exceeds 150 % in stable operation.

Beam axis alignment and operation confirmation [Sensor head]

Supports beam axis alignment at startup and quick restoration in case of trouble [High-functional type ST4-C12EX]

Light received condition of the sensor heads in series connection can be confirmed by the high-functional controller ST4-C12EX.
In addition, any abnormal sensors during lockout can be identified.

Supports beam axis alignment at startup and quick restoration in case of trouble [High-functional type ST4-C12EX]

In small openings where safety light curtains cannot be installed

Ensures safety in small openings that are often missed.

In small openings where safety light curtains cannot be installed

Compact sensor head saves space

The Type 4 long sensing range type has a compact size that is equivalent to those of general-purpose photoelectric sensors.

Compact sensor head saves space

Industry standard mounting pitch [Sensor head]

Having the same mounting pitch as those of general-purpose photoelectric sensors makes model switchovers easy.

Industry standard mounting pitch [Sensor head]

Waterproof IP67

Conforming to IP67 rating, the sensor heads can be used safely even at lines where water splashes during washing.

Protection structure IP67 [Sensor head]

Control of interferences to surrounding sensors [Sensor head]

The emission amount adjuster can be used to reduce the emission to control any interference to the surrounding sensors.

Control of interferences to surrounding sensors [Sensor head]

Supports both PNP and NPN polarities [Controller]

A single unit can be used for PNP / NPN output switching, reducing the number of parts that need to be registered.

Supports both PNP and NPN polarities [Controller]

Easy connector connection [Controller]

Connecting to the sensor head is done using connector connections, which shortens setup and replacement time.

Easy connector connection [Controller]

Easy setup requiring no torque control

A spring method is used for the terminal blocks. There is no need to control tightening torques for these terminal blocks.

Connection is possible with a single wire or coil wires.

Removal terminal blocks reduce maintenance time

The work required for reconnecting wiring during maintenance is reduced.

Semiconductor output reduces running costs! [Controller]

Semiconductor output is used for control output. This means there is no need to periodically replace safety relays.

Semiconductor output reduces running costs! [Controller]

Error details can be understood at a glance! [High-functional type ST4-C12EX]

If a problem should occur, the control output is switched OFF, and the details of the error appear on the digital display.

Error details can be understood at a glance! [High-functional type ST4-C12EX]

Three patterns of muting control function for greater safety with no loss in productivity [High-functional type ST4-C12EX]

Sensor heads, muting sensors, and muting lamps connect directly to the controller, so that muting control circuits can be built easily.

Three patterns of muting control function for greater safety with no loss in productivity [High-functional type ST4-C12EX]
Three patterns of muting control function for greater safety with no loss in productivity [High-functional type ST4-C12EX]

Muting pattern No.1 Compliant to international safety standard ISO 12643 for printing industry Muting area can be changed to suit the printing process. This is the optimal muting control for printing machines.

(1)Put in an unfilled palette (Bottom-most muting)
(2)Sample inspect the printing paper (Top-most muting)
(3)Take out the printed material (All muting)

Muting pattern No.2

Set apart only the top-most sensor heads and perform muting control.

Muting pattern No.2

Muting pattern No.3

Divide the muting area into two.

Muting pattern No.3

Line restarts smoothly after being stopped while muting control was active <Override function> [High-functional type ST4-C12EX]

In case the sensor head has been interrupted by an object or in case there is an emergency stop before the muting conditions have been established, all the sensor heads will be temporarily deactivated following by a smooth restart.

Line restarts smoothly after being stopped while muting control was active <Override function> [High-functional type ST4-C12EX]

Informs all kinds of operation conditions [High-functional type ST4-C12EX]

In case the muting lamp that is connected to the controller breaks, an alarm will go off. Also, auxiliary outputs that link to the muting function, override function, and control outputs (OSSD) are incorporated.

Auxiliary outputs Function Operation
Auxiliary output 1 Muting output ON when muting function is invalid
Auxiliary output 2 Override output ON when override function is invalid
Auxiliary output 3 Blown lamp output ON when muting lamp is in normal condition
Auxiliary output 4 Monitor output ON when control output is OFF

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)