【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Wire-Saving Systems > Flexible Wire-saving System S-LINK V > System Configuration
Discontinuation plan
|
|
>> System layout (PDF)
Operating only the controller, communication modes can be selected for the entire system. Thanks to the three A, B, or C selectable modes, you don't need to reconfigure or modify the controller or the I/O units depending on the communication speed or the size of your system. By selecting a communication mode corresponding to the speed and communication range, the desired communication speed / range environment can also be realized.
Comm. Mode (Note 4) | A-mode | B-mode | C-mode |
---|---|---|---|
Refresh time (Note 1) | 1.5 ms or less (for 32 points) 3.3 ms or less (for 128 points) 10.3 ms or less (for 512 points) |
6.0 ms or less (for 32 points) 13.1 ms or less (for 128 points) 41.3 ms or less (for 512 points) |
24.0 ms or less (for 32 points) 52.3 ms or less (for 128 points) 165.2 ms or less (for 512 points) |
Max. communication range (Note 2) | 50 m 164.042 ft | 200 m 656.168 ft | 800 m 2624.672 ft |
Total cable length | 100 m 328.084 ft | 400 m 1312.336 ft | 1600 m 5249.344 ft |
I/O control points | 32 to 512 points (set in 32 point step)(Note 3) | ||
Number of connected nodes | Maximum 256 nodes |
Notes:
1) | This value represents the maximum refresh time. |
---|---|
2) | The maximum communication range varies depending on the cables' conductor cross-section area as well as the node count. |
3) | 16 units of measure settable by software in the control board (SL-VISA, SL-VPCI, SL-VVMES2). |
4) | Communication modes cannot be changed while a communication is in progress. |
I/O modules that can connect I/O devices with custom boards are available so that you can choose the components that best suit your project's specifications.
The SL-VHM1 can operate and monitor all units that are connected to the system, putting efficient debugging (checking) of I/O devices installed in remote locations at your fingertips.
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)