【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Ultra-compact Ionizer ER-V > Specifications
|
Type | Spot type | ||
---|---|---|---|
Model No. | ER-VS02 | ER-VS01 | |
Charge removal time (±1,000 V → ±100 V) |
1 sec. or less (Note 2) | ||
Ion balance | ±10 V or less (Note 2) | ||
Ozone generation | 0.03 ppm or less (Note 3) | ||
Applicable fluid | Air (dried clean air) (Note 4) | ||
Supplied air flow | 500 ℓ/min. (ANR) or less (Note 5) | ||
Air pressure range | 0.05 to 0.7 MPa (Note 5) | ||
Supply voltage | 24 V DC ±10 % | ||
Current consumption | 70 mA or less | ||
Discharge method | High frequency AC method | ||
Discharge output voltage | 2,000 V approx. | ||
Check output(CHECK) | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between check output and 0 V) ・Residual voltage: 1 V or less (at 50 mA sink current) |
||
Output operation | ON when a dirt or worn etc. of the discharge needle is detected for 1.5 sec. or more continuously, OFF when operation is normal (Note 6) | ||
Short-circuit protection |
Incorporated | ||
Error output(ERROR) | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between error output and 0 V) ・Residual voltage: 1 V or less (at 50 mA sink current) |
||
Output operation | OFF when abnormal discharge is detected, ON when operation is normal | ||
Short-circuit protection | Incorporated | ||
Discharge halt input (DSC OFF) (Note 7) |
Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start) | ||
Reset input | When abnormal discharge is detected, discharge is halted due to an error. Reset the discharge halt by briefly shorting the power supply's 0 V line. | ||
Indicators | Power(POWER) | Green LED (lights up when the power is ON) | |
Discharge(DSC) (Note 7) | Green LED (lights up when discharging) | ||
Check(CHECK) | Orange LED (lights up when the discharge needle is worn or dirty, etc.) (Note 6) | ||
Error(ERROR) | Red LED (lights up when abnormal discharge is detected) | ||
Environmental resistance | Ambient temperature | 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed) | |
Ambient humidity | 35 to 65 % RH | ||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | ||
Cable | Cable with a connector, 0.5 m 1.640 ft long | ||
Material | Enclosure: PPS, Cover: Stainless steel, Discharge needle: Tungsten | ||
Weight | Net weight: 120 g approx. | ||
Accessory | Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08R), Terminal (5556TL)] |
Note:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
3) | A typical sample applied with a power voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. |
4) | Dried clean air is the air passing through air dryer (dew point –20℃ –4℉ approx.) and air filter (mesh size 0.01 μm 0.0004 mil approx.) |
5) | The applicable pressure range depends on the nozzle to be used. |
6) | When confirming the check output, carry out discharge for 2 sec. or more. |
7) | ”DSC” is an abbreviated name of ”DISCHARGE”. |
Type | Shower nozzle | Straight bar nozzle 200 mm 7.874 in |
Straight bar nozzle 320 mm 12.598 in |
Straight bar nozzle 650 mm 25.591 in |
---|---|---|---|---|
Model No. | ER-VAS | ER-VAB020 | ER-VAB032 | ER-VAB065 |
Supplied air pressure range | 0.05 to 0.40 MPa | |||
Charge removal range | - | 200 mm 7.874 in | 320 mm 12.598 in | 650 mm 25.591 in |
Material | Stainless steel | |||
Accessories | Attachment and insulation pipe: 1 pc. each | Attachment and insulation pipe: 1 pc. each, Straight bar nozzle holder: 1 set |
Type | Shape-preserving tube joint nozzle | Conductive tube joint nozzle |
---|---|---|
Model No. | ER-VAJK | ER-VAJT-64 |
Air pressure range | 0.02 to 0.5 MPa | 0.02 to 0.4 MPa .(Maximum applied pressure depends on the tube length.) |
Material | Stainless steel | Stainless steel |
Supplied air flow | 30 to 250 ℓ/min. (ANR) | 20 to 100 ℓ/min. (ANR) (at applied pressure of 0.02 to 0.4 MPa) |
Accessories | Attachment (White): 1pc. Insulation pipe: 1pc. |
Attachment (White): 1pc. Insulation pipe: 1pc. |
Type | Shape-preserving tube | Conductive tube | ||
---|---|---|---|---|
Model No. | ER-VAK10 | ER-VAK30 | ER-VAK50 | ER-AT50 |
Tube length | 112 mm 4.409 in | 312 mm 12.283 in | 512 mm 20.157 in | 500 mm 19.685 in |
Material | Tube interior: Aluminum Tube sheath: High-density polyethylene Terminal cap: Stainless steel |
Urethane | ||
Air pressure range | 0.02 to 0.5 MPa | 0.02 to 0.4 MPa | ||
Minimum bending radius | R40 mm R1.575 in or more | R15 mm R0.591 in or more |
Type | Tube and joint set |
---|---|
Model No. | ER-VAB-AT |
Compatible nozzles | Straight nozzle (effective charge removal length 320 mm 12.598 in or less) |
Tube length | 500 mm 19.685 in |
Material | Nozzle: Stainless steel (SUS), Conductive tube: Urethane |
Supplied air flow | Max. 200 ℓ/min. (ANR) |
Air pressure range | 0.05 to 0.4 MPa |
Minimum bending radius | R25 mm R0.984 in (conductive tube portion) |
Accessories | Attachment (Black) 1 pc., insulated pipe: 1pc., Straight bar nozzle holder: 1 set |
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. - Correlation between tube length and maximum applied pressure
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)