Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > HE-N Relays > Part Number > AHE62X5N
*Photo may vary from actual product.
Product Number | HE1aN-W-DC9V-Y7 |
Part Number | AHE62X5N |
Details | 120 A |
Product name | HE-N Relays |
Features | High capacity 120 A 490 V AC 1 Form A power relay |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
As of April 26, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | HE1aN-W-DC9V-Y7 |
Part Number | AHE62X5N |
Protective construction | Flux-resistant |
Operating function | Single side stable |
Terminal shape | PC board terminal (wide blade) |
Contact rating type | 120 A |
Insulation distance | Min. 10.5 mm (Clearance and Creepage) (Initial) |
Contact gap | Min. 3.6 mm (Initial) |
Standard packing Carton (pieces) |
10 |
Standard packing Case (pieces) |
50 |
Item | Specifications |
---|---|
Rated coil voltage | 9 V DC |
Operate voltage (at20°C) | Max. 75% V of rated coil voltage (Initial) |
Release voltage (at20°C) | Min. 5% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20°C) | 278 mA |
Coil resistance [±10%] (at 20°C) | 32.4 Ω |
Rated operating power | 2,500 mW |
Max. allowable voltage | 110% V of rated coil voltage (at 55°C) |
Item | Specifications |
---|---|
Contact arrangement | 1 Form A |
Contact shape | Single |
Contact resistance (initial) | Max. 10 mΩ (by voltage drop 5 V DC 20 A) Max. 3 mΩ (by voltage drop 5 V DC 120 A, reference value) |
Contact material | AgNi type |
Contact rating (resistive load) | 120 A 490 V AC, 120 A 60 V DC |
Max. switching power (resistive load) | 58,800 VA (AC), 7,200 W (DC) |
Max. switching voltage | 800 V AC, 60 V DC |
Max. switching current | 120 A (AC, DC) |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 10,000 V |
Coil holding voltage | 40 to 100% V (at -40~55°C) 50 to 60% V (at 55~85°C) |
Operate time (initial) (at 20°C) | Max. 30 ms at rated coil voltage (without bounce) |
Release time (initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
Shock resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Shock resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical life | Min. 106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 115 g |
Item | Specifications |
---|---|
Resistive load | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 55 A 800 V AC Min. 10x103 ope. 90 A 490 V AC Min. 103 ope. 120 A 490 V AC [switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 120 A 60 V DC |
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)