ALZN1B05W | LZ-N Relays


LZ-N Relays

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  
  • Download RoHS Compliance Certificate


  • To Be Discontinued
  • Last time buyMarch 31, 2025
Product Number ALZN1B05W
Part Number ALZN1B05W
Product name LZ-N Relays
Features EN60335-1 GWT compliant, 15.7 mm Low profile, 1 Form A/1 Form C 16 A, Power relays

*“ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market.


As of April 17, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number ALZN1B05W
Part Number ALZN1B05W
Protective construction Flux-resistant
Operating function Single side stable
Terminal shape PC board terminal
Relay shape Low profile type
Coil insulation class Class B insulation
Standard packing
Carton (pieces)
100
Standard packing
Case (pieces)
500

Coil data

Item Specifications
Rated coil voltage 5 V DC
Operate voltage (at20°C) Max. 70% V of rated coil voltage (Initial)
Release voltage (at20°C) Min. 10% V of rated coil voltage (Initial)
Rated operating current [±10%] (at 20°C) 80 mA
Coil resistance [±10%] (at 20°C) 63 Ω
Rated operating power 400 mW
Max. allowable voltage 120% V of rated coil voltage (at 85°C)

Specifications

Item Specifications
Contact arrangement 1 Form C
Contact shape Single
Contact resistance (initial) Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material AgSnO2 type
Contact rating (resistive load) 16 A 250 V AC
Max. switching power (resistive load) 4,000 VA
Max. switching voltage 440 V AC
Max. switching current 16 A
Min. switching load (reference value) 100 mA 5 V DC
Insulation resistance (initial) Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength (initial) : Between open contacts 1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric strength (initial) : Between contact and coil 5,000 Vrms for 1 min (detection current: 10 mA)
Surge withstand voltage (initial) : Between contact and coil 10,000 V
Operate time (initial) (at 20°C) Max. 15 ms at rated coil voltage (without bounce)
Release time (initial) (at 20°C) Max. 5 ms at rated coil voltage (without bounce, without diode)
Shock resistance (Functional) 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Shock resistance (Destructive) 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance (Functional) 10 to 55 Hz (at double amplitude of 1.5 mm, Only the N.C. contact is 0.8 mm, detection time: 10 µs)
Vibration resistance (Destructive) 10 to 55 Hz (at double amplitude of 1.5 mm)
Mechanical life Min. 106 ope. (switching frequency: at 180 times/min)
Conditions Ambient temperature: -40 to +85°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 11 g

Expected electrical life

Item Specifications
Resistive load [at 20°C, switching frequency: at 20 times/min (ON : OFF = 1.5 s : 1.5 s)]
N.O.: Min. 50x103 ope. 16 A 250 V AC
N.C.: Min. 10x103 ope. 16 A 250 V AC

Return to top

Information on Compliance with Standards

Standard Name Status Information on Compliance
UL/C-UL

Approval

File No. E43149
Rating (NO side)
10A 277V AC Resistive
100K cycles at 105°C
16A 277V AC Resistive
100K cycles at 85°C
20A 277V AC General use
6K cycles at 40°C
34.8 LRA/7.2 FLA 120V AC
Definite purpose
200K cycles at 50°C
50 LRA/10 FLA 250V AC
see conditions of acceptability
30K cycles at 70°C
1/2 HP 240V AC
100K cycles at 40°C

(NC side)
16A 277V AC Resistive
10K cycles at 40°C
16A 277V AC Resistive
6K cycles at 85°C
34.8 LRA/7.2 FLA 120V AC
Definite purpose
200K cycles at 50°C
Remarks -
Last update July 8, 2019
CSA

N/A

File No. -
Rating -
Remarks CSA standard certified by C-UL
Last update July 8, 2019
VDE

Approval

File No. 40047387
Rating (NO side)
16A 250V AC (cosφ=1.0)
100K cycles at 25°C
16A 250V AC (cosφ=1.0)
50K cycles at 85°C
13A 250V AC (cosφ=1.0)
100K cycles at 85°C

(NC side)
16A 250V AC (cosφ=1.0)
10K cycles at 25°C
Remarks -
Last update December 6, 2022
TV

Approval

File No. E43149
Rating (NO side)
TV-5
120V AC 25K cycles at 40°C
Remarks -
Last update July 8, 2019
Mark on products* UL C-UL Recognaized VDE HOUSE MARK

* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.


Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)