AUTOMATION
CONTROLS

Search
Discontinued
Products



FX-505-C2 | Digital Fiber Sensor FX-500 Ver.2


Digital Fiber Sensor FX-500 Ver.2

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number FX-505-C2
Part Number FX-505-C2
Product Digital Fiber Sensor
Details Cable type
Product name Digital Fiber Sensor FX-500 Ver.2

As of April 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number FX-505-C2
Part Number FX-505-C2
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing certification
Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less
Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output)
ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output)
Output 1, Output 2 NPN open-collector transistor
- Maximum sink current: 50 mA (Note 1)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (Note 2) (at maximum sink current)
(Note 1) 50 mA max. if 5 or more standard types are connected together.
(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)
Output 1, Output 2:Output points 2 points
Output 1, Output 2:Output operation Switchable either Light-ON or Dark-ON by L/D mode
Output 1, Output 2:Short-circuit protection Incorporated
Response time H-SP: 25 micro s or less
FAST: 60 micro s or less
STD: 250 micro s or less
LONG: 2 ms or less
U-LG: 4 ms or less
HYPR: 24 ms or less, selectable
Analog output Output current: 4 to 20 mA approx. [H-SP, FAST STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note) ]
Response time: 2 ms or less
Zero point: Within 4 mA plus or minus 1 % F.S.
Span: Within 16 mA plus or minus 5 % F.S.
Linearity: Within plus or minus 3 % F.S.
Load resistance: 0 to 250 Ohm
(Note) If display adjustment was conducted, it is not in this range.
External input NPN non-contact input
- Signal condition
High: +8 V to +V DC or Open
Low: 0 to +1.2 V DC(at 0.5 mA source current)
- Input impedance: 10 kOhm approx.
External input(switchable with Output 2) -
Possible external input function Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy lock / Display adjustment / Data bank load / Data bank save, selectable
Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Incident light intensity display range H-SP / FAST / STD: 0 to 4,000
LONG: 0 to 8,000
U-LG / HYPR: 0 to 9,999
Timer function Incorporated with variable OFF-delay / ON-delay /One-shot / ON-delay - OFF-delay / ON-delay - One-shot timer, switchable either effective or ineffective
Incorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either effective or ineffective
Timer function:Timer period Timer range ''ms'': 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.
Timer range ''sec.'': 0.5 s approx., 1 to 32 s approx., 1 s approx.
Timer range ''1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx.
each output is set individually
Emission amount setting function Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode]
Interference prevention function Incorporated (Note) , selectable either automatic interference prevention or different frequency
(Note) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.
- Number of sensor heads mountable closely (Unit: set)
Response time: IP-1
H-SP: 0
FAST: 2
STD: 4
LONG: 8
U-LG: 8
HYPR: 12
Various settings Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold value tracking setting, etc.
Protection IP40 (IEC)
Ambient temperature -10 to +55 ℉ +14 to +131 ℉ [If 4 to 7 units are mounted in cascade: -10 to +50 ℉ +14 to +122 ℉ or if 8 to 12 units are mounted in cascade: -10 to +45 ℉ +14 to +113 ℉ ] (No dew condensation or icing allowed), Storage: -20 to +70 ℉ -4 to +158 ℉ 
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Emitting element (modulated) Red LED (Peak emission wavelength: 643 nm 0.025 mil)
Material Enclosure, Case cover: Polycarbonate
Switch: Polyacetal
Cable 0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (however, supply voltage 12 V DC or more)
Weight Net weight: 60 g approx.
Gross weight: 100 g approx.
Accessory FX-MB1 (Amplifier protection seal): 1 set

Return to top

Accessories (Option)

Super Quality Fiber
Product Number FD-30
Part Number FD-30
Product Reflective type Fiber
Details Super Quality Fiber
Product name Super Quality Fiber
Threaded Type Fiber
Product Number FD-31
Part Number FD-31
Product Reflective type Fiber
Details Threaded Type Fiber
Product name Threaded Type Fiber
Threaded Type Fiber
Product Number FD-31W
Part Number FD-31W
Product Reflective type Fiber
Details Threaded Type Fiber
Product name Threaded Type Fiber


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)