HL-C2C | Ultra High-speed・High-precision Laser Displacement Sensor HL-C2


Ultra High-speed・High-precision Laser Displacement Sensor HL-C2

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


  • To Be Discontinued
  • Last time buyMarch 31, 2025
Product Number HL-C2C
Part Number HL-C2C
Product Ultra High-speed High-precision Laser Displacement Sensor
Details Controller
Product name Ultra High-speed・High-precision Laser Displacement Sensor HL-C2
  • Substitute -
  • Sub Prod No. -
  • Sub Part No. -
  • Remark Sorry, no suggested alternative products.

As of April 18, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number HL-C2C
Part Number HL-C2C
Connectale sensor head Number of connectable units: Max. 2 units.
Supply voltage 24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Current consumption 500 mA approx. at 2 sensor heads connected
350 mA approx. at 1 sensor head connected
(100 mA approx. is additionally required when the mini console is connected)
Sampling rate 10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Analog output : Voltage Voltage output scale: -5 to +5 V/F.S (initial value)
Output range during normal status: -10.0 to +10.0 V
Output at abnormal status: -10.8 V or +10.8 V
Resolution: 2 mV, Linearity: plus or minus 0.05 % F.S.
Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx.
(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Analog output : Current Current output scale: 4 to 20 mA/F.S (initial value)
Output range during normal status: 2 to 24 mA
Output at abnormal status: 1 mA or 25 mA
Resolution: 3 micro A, Linearity plus or minus 0.05% F.S.
Load impedance: 250 Ohm max., Response delay time: 10 micro s approx.
(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
Alarm output NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less[between alarm output and Common(-)]
- Residual voltage: 1 V or less(at 100 mA sink current)
Alarm output : Output operation Opened when the amount of light is insufficient
Alarm output : Short-circuit protection Incorporated
Judgment output (HI, GO, LO) NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less[between judgment output to Common(-)]
- Residual voltage: 1 V or less(at 100 mA sink current)
Judgment output (HI, GO, LO): Output operation Opened at output operation
Judgment output (HI, GO, LO) : Short-circuit protection Incorporated
Strobe output NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less[between strobe output to Common(-)]
- Residual voltage: 1 V or less(at 100 mA sink current)
Strobe output : Output operation Opened at data determination
Strobe output : Short-circuit protection Incorporated
Remote interlock input Laser emission is delayed when connected to Common (-).
Laser emission stop at open
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Laser control input Laser emission is stopped when connected to Common (-).
Laser is emitted immediately after opened.
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Zero set input Zero set is ON when connected with Common (-).
Zero set turns to OFF after continuously connected to Common (-) for one second.
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Timing input ON at/during connection to Common (-)(depending on analysis mode)
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Reset input Reset is done when connected to Common (-).
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Memory change input Memory is specified when connected to Common (-).
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Indicator : Power Green LED (lights up at power on)
Indicator : Sensor head A Laser radiation Green LED (lights up during or immediately before laser emission of sensor head A)
Indicator : Sensor head B Laser radiation Green LED (lights up during or immediately before laser emission of sensor head B)
Indicator : Alarm 1 Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Indicator : Alarm 2 Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Environmental resistance : Ambient temperature 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Environmental resistance : Ambient humidity 35 to 85 %RH
Environmental resistance : Vibration resistance 10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
Environmental resistance : Shock resistance 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Material Case: Polycarbonate
Weight 450 g approx.
Accessory USB cable (2 m 6.562 ft long): 1 pc.
Short bracket: 1 pc.

Return to top

Accessories (Option)

To Be Discontinued

no_image
Product Number HL-C2CCJ10
Part Number HL-C2CCJ10
Product name Extension Cable

To Be Discontinued

no_image
Product Number HL-C2CCJ2
Part Number HL-C2CCJ2
Product name Extension Cable

To Be Discontinued

no_image
Product Number HL-C2CCJ20
Part Number HL-C2CCJ20
Product name Extension Cable


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)