Business
> Industrial Devices
> Automation Controls Top
> FA Sensors & Components
> Sensors
> Light Curtains / Safety Components
> Non-Contact Safety Door Switch SG-P
> Part Number
> SG-P2010-S
![]() |
*Photo may vary from actual product.
Product Number | SG-P2010-S |
Part Number | SG-P2010-S |
Product | Non-Contact Safety Door Switch |
Details | Compact type (High code / Sub) |
Product name | Non-Contact Safety Door Switch SG-P |
As of May 24, 2022
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | SG-P2010-S |
Part Number | SG-P2010-S |
Applicable standards:International standard | ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 |
Applicable standards:Japan | JIS B 9705-1, JIS C 0508 1 to 7, JIS B 9961, JIS C 8201-5-2, JIS B 9710 |
Applicable standards:Europe (EU) | EN ISO 13849-1 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 |
Applicable standards:North America | CAN/CSA C22.2 No.14, UL508 |
Applicable standards and certifications | CE Marking (Machinery Directive, RE Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification (U.S.A., Canada), the U.S.'s radio regulations (FCC), Canada's radio regulations (ICES-003, RSS-310), Singapore's radio regulations (IMDA) |
Operating distance : Front / Side | Sao (OFF→ON): 5 mm 0.197 in, Sar (ON → OFF): 15 mm 0.591 in |
Power voltage | 24V DC+10-20% Ripple P-P 10 % or less |
Current consumption | 20 mA or less |
Control outputs (OSSD 1, OSSD 2) | — |
Control outputs (OSSD 1, OSSD 2):Operation mode | — |
Control output(OSSD):Protection circuit | — |
Response time | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less • For multiple units: Time for single unit + 5 ms x (number of connected units - 1) |
Check input and output | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note) * It is not for external input and output. (voltage range 0 V to 5 V DC) (Note) : When using the device as a single unit, connect the check input with the check output. |
Number of units connected in series | 30 units or less (standard 1 unit, sub 29 units) |
Pollution degree | 3 |
Environmental resistance:Degree of protection | IP65(IEC) |
Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +65 ℃ -13 to +149 ℉ |
Environmental resistance:Ambient humidity | 30 to 85 % RH, storage: 30 to 95 % RH |
Environmental resistance:Voltage withstandability | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
Environmental resistance:Insulation resistance | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Environmental resistance:Vibration resistance | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions |
Environmental resistance:Shock resistance | 300 m/s2 (approx. 30 G), 3 times each in X, Y, and Z direction |
Material | Switch body: PBT, PC, SUS (stainless steel), EPDM Actuator: PBT |
Cable | 4–core cabtyre cable, 3 m 9.843 ft long |
Connected cable length | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit • When connecting multiple units in series: Maximum total cable length of 100 m 328.084 ft, maximum cable length of 20 m 65.617 ft between two adjacent units |
Weight | Switch body (sub): 110 g approx., Actuator: 10 g approx. |
Gross weight | 190 g approx. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃ +73 ℉. ■Transponder specifications Operating frequency: 125 kHz Max. transmitter output: 3.33 μW |
![]() |
Product Number | ![]() |
Part Number | SG-PK-M2 |
Product name | Maintenance actuator |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)