There are more the 40 different models in the Safety Light Curtain SF4B Series and their modular design makes them easy to expand. These compact, Type 4 Safety Light Curtains comply with EN 61496-1 /-2 and EN ISO 13849 performance level (PLe). The SF4B Series are available in three (3) different beam pitches (10 mm, 20 mm and 40 mm) and in numerous sensing heights.
The SF4B Series offers flexibility and a wide range of accessories such as mounting brackets and extension cables. Cables for Series connection are also available to eliminate dead zones. The SF4B Series can now be equipped with corner mirrors to reduce setup work and wiring.
Part No. | Datasheet | CE Marking Directive Compliance | No. of Beam Channels | Protective Height | Protective Height: China Press Compliant (GB/T 4584) | Current Consumption | PFH<sub>D</sub> | MTTF<sub>D</sub> | Weight (Total Of Emitter And Receiver) | Applicable Standards: International Standard | Applicable Standards: Japan | Applicable Standards: Europe (EU) | Applicable Standards: North America | Applicable Standards: South Korea (S-Mark) | Applicable Standards: China (GB) | Operating Range | Min. Sensing Object | Effective Aperture Angle | Power Voltage | Control Outputs (OSSD 1, OSSD 2) | Control Outputs (OSSD 1, OSSD 2): Operation Mode | Control Outputs (OSSD1, OSSD2): Protection Circuit | Response Time | Auxiliary Output (Non-Safety Output) | Auxiliary Output (Non-Safety Output): Operation Mode | Auxiliary Output (Non-Safety Output): Protection Circuit | Auxiliary Output (Non-Safety Output): Response Time | Interference Prevention Function | Emission Halt Function | Interlock Function | External Device Monitoring Function | Override Function | Muting Function | Optional Functions | Environmental Resistance: Degree of Protection | Ambient Temperature | Ambient Humidity | Ambient Illuminance | Environmental Resistance: Dielectric Strength Voltage | Vibration Resistance | Insulation Resistance | Shock Resistance | Emitting Element | Material | Connecting Method | Cable Length | Accessories | Applicable Standards: China |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Machinery Directive, EMC Directive, RoHS Directive | 88 | 1,750 mm 68.898 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,740mm 68.503 in | Emitter: 120 mA or less Receiver: 200 mA or less | 5.6 × 10–9 | 100 years or more | 3,370 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 3 sets SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 80 | 1,590 mm 62.598 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,580mm 62.205 in | Emitter: 110 mA or less Receiver: 180 mA or less | 5.2 × 10–9 | 100 years or more | 3,070 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 2 sets SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||||
Machinery Directive, EMC Directive, RoHS Directive | 96 | 1,910 mm 75.197 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,900mm 74.803 in | Emitter: 120 mA or less Receiver: 200 mA or less | 6.0 × 10–9 | 100 years or more | 3,670 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 3 sets SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 80 | 1,590 mm 62.598 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,580mm 62.205 in | Emitter: 110 mA or less Receiver: 180 mA or less | 5.2 × 10–9 | 100 years or more | 3,070 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 2 sets SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 40 | 790 mm 31.102 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 780mm 30.708 in | Emitter: 90 mA or less Receiver: 140 mA or less | 3.2 × 10–9 | 100 years or more | 1,570 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 1 set SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 64 | 1,270 mm 50.000 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,260mm 49.606 in | Emitter: 100 mA or less Receiver: 160 mA or less | 4.4 × 10–9 | 100 years or more | 2,470 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 2 sets SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 56 | 1,110 mm 43.701 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,100mm 43.701 in | Emitter: 100 mA or less Receiver: 160 mA or less | 4.0 × 10–9 | 100 years or more | 2,170 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 1 set SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||||
Machinery Directive, EMC Directive, RoHS Directive | 48 | 950 mm 37.402 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 940mm 37.007 in | Emitter: 90 mA or less Receiver: 140 mA or less | 3.6 × 10–9 | 100 years or more | 1,870 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 1 set SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||||
Machinery Directive, EMC Directive, RoHS Directive | 72 | 1,430 mm 56.299 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,420mm 55.905 in | Emitter: 110 mA or less Receiver: 180 mA or less | 4.8 × 10–9 | 100 years or more | 2,770 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 2 sets SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||||
Machinery Directive, EMC Directive, RoHS Directive | 28 | 550 mm 21.654 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 540mm 21.260 in | Emitter: 80 mA or less Receiver: 115 mA or less | 2.6 × 10–9 | 100 years or more | 1,110 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated (Note) Please use 12-core cable. | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | SF4B-TR25 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. |