Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > Power Relays (Over 2A) Lineup > DS Power Relays > Rating/Performance
|
Rated coil voltage | Operate voltage * (at 20°C) |
Release voltage * (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
3 V DC | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 100 mA | 30 Ω | 300 mW | 130% V of rated coil voltage |
5 V DC | 60.2 mA | 83 Ω | ||||
6 V DC | 50 mA | 120 Ω | ||||
9 V DC | 33.3 mA | 270 Ω | ||||
12 V DC | 25 mA | 480 Ω | ||||
24 V DC | 12.5 mA | 1,920 Ω |
* | square, pulse drive |
---|
Rated coil voltage | Set voltage * (at 20°C) |
Reset voltage * (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
3 V DC | Max. 80% V of rated coil voltage (Initial) |
Max. 80% V of rated coil voltage (Initial) |
50 mA | 60 Ω | 150 mW | 130% V of rated coil voltage |
5 V DC | 30.1 mA | 166 Ω | ||||
6 V DC | 25 mA | 240 Ω | ||||
9 V DC | 16.7 mA | 540 Ω | ||||
12 V DC | 12.5 mA | 960 Ω | ||||
24 V DC | 6.3 mA | 3,840 Ω |
* | square, pulse drive |
---|
Rated coil voltage |
Set voltage * (at 20°C) |
Reset voltage * (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
|||
---|---|---|---|---|---|---|---|---|---|
Set coil | Reset coil | Set coil | Reset coil | Set coil | Reset coil | ||||
3 V DC | Max. 80% V of rated coil voltage (Initial) |
Max. 80% V of rated coil voltage (Initial) |
100 mA | 100 mA | 30 Ω | 30 Ω | 300 mW | 300 mW | 130% V of rated coil voltage |
5 V DC | 60.2 mA | 60.2 mA | 83 Ω | 83 Ω | |||||
6 V DC | 50 mA | 50 mA | 120 Ω | 120 Ω | |||||
9 V DC | 33.3 mA | 33.3 mA | 270 Ω | 270 Ω | |||||
12 V DC | 25 mA | 25 mA | 480 Ω | 480 Ω | |||||
24 V DC | 12.5 mA | 12.5 mA | 1,920 Ω | 1,920 Ω |
* | square, pulse drive |
---|
Item | Specifications | |||
---|---|---|---|---|
Contact data |
Contact arrangement | 1 Form A | 1 Form A 1 Form B | 2 Form A |
Contact resistance (initial) |
Max. 30 mΩ (by voltage drop 6 V DC 1 A) | |||
Contact material | Au-flashed AgSnO2 type | |||
Contact rating (resistive) | 8 A 250 V AC, 5 A 30 V DC |
5 A 250 V AC, 5 A 30 V DC | ||
Max. switching power (resistive) | 2,000 VA, 150 W | 1,250 VA, 150 W | ||
Max. switching voltage | 250 V AC, 125 V DC (0.2 A) | |||
Max. switching current | 8 A (AC), 5 A (DC) | 5 A (AC, DC) | ||
Min. switching load (reference value) *1 | 10 mA 5 V DC | |||
Insulation resistance (Initial) |
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
|||
Dielectric strength (initial) | Between open contacts |
1,000 Vrms for 1 min (detection current:10 mA) | ||
Between contact sets |
- | 2,000 Vrms for 1 min (detection current: 10 mA) | ||
Between contact and coil |
3,000 Vrms for 1 min (detection current: 10 mA) | |||
Surge withstand voltage (initial) *2 | Between contact and coil |
5,000 V | ||
Time characteristics (initial) | Operate (Set) time | Max. 10 ms (Max. 10 ms) at rated coil voltage (at 20°C, without bounce) | ||
Release (Reset) time | Max. 5 ms (Max. 10 ms) at rated coil voltage (at 20 °C, without bounce, without diode) | |||
Shock resistance |
Functional | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) | ||
Destructive | 980 m/s2 (half-sine shock pulse: 6 ms) | |||
Vibration resistance |
Functional | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs) | ||
Destructive | 10 to 55 Hz (at double amplitude of 3.5 mm) | |||
Expected life | Mechanical life | Min. 50 x 106 ope. (switching frequency: at 180 times/min) | ||
Conditions | Conditions for usage, transport and storage *3 |
Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Ambient temperature: -40 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 4.5 g |
*1 | This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. |
---|---|
*2 | Wave is standard shock voltage of ±1.2 x 50 μs according to JEC-212-1981 |
*3 | For ambient temperature, please read "GUIDELINES FOR RELAY USAGE". |
Conditions: Resistive load, switching frequency at 20 times/min
Type | Switching capacity | Number of operations |
---|---|---|
1 Form A | 8 A 250 V AC | Min. 100 x 103 ope. |
5 A 30 V DC | Min. 100 x 103 ope. | |
1 Form A 1 Form B | 5 A 250 V AC | Min. 100 x 103 ope. |
5 A 30 V DC | Min. 100 x 103 ope. | |
2 Form A | 5 A 250 V AC | Min. 100 x 103 ope. |
5 A 30 V DC | Min. 100 x 103 ope. |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])