[Notification of CAD Data Download Issue]   We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.

AUTOMATION
CONTROLS

Search
Discontinued
Products



AJ7 (J7) Switches

Specifications

Contact rating

Type Contact voltage Resistive load
(Power factor = 1)
Motor load* (EN61058-1)
(Power factor = 0.6)
Inrush load
10A AC250V 10A 4A 100A (8.3ms)
6A 6A 3A
*The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating.

TV rating

Contact voltage Resistive load Motor load (EN61058-1) Capacitor load
(EN61058-1)
Lamp load (UL61058-1) Expected electrical life
(Power factor = 1) (Power factor = 0.6) (Inrush load) (TV‐5) (at 7 cpm)
120V AC 5/78A Min. 2.5 × 104
250V AC 10A 4A 100A (8.3ms) Min. 104

Return to top

Characteristics

Item Specifications (common to 10 A and 6 A types)
Expected life
(Min. operations)
Mechanical Min. 5 x 104 (at 20 cpm.)
Electrical (at rated load)* Min. 104 (at 7 cpm.)
Insulation resistance Min. 100 MΩ (at 500 V DC measured by insulation resistive meter) (Between terminals)
Dielectric strength Initial, 2,000 Vrms for 1 min (detection current: 10 mA) (Between terminals)
Contact resistance Initial, Max. 100 mΩ (By voltage drop at 1 A, 2 to 4 V DC)
Temperature rise (terminal section) Max. 30°C at 6 x 103 ope. or less (UL61058-1),
Max. 55°C from 6 x 103 ope. to 104 (EN61058-1)
Vibration resistance 10 to 55 Hz at double amplitude of 1.5mm (Contact opening Max. 1 msec.)
Shock resistance Min. 980 m/s2
Actuator strength 40 N for 1 minute (operating direction)
Tensile terminal strength 100 N for 1 minute or more (Pull & push direction)
Ambient temperature -25°C to +85°C (no freezing and condensing)
Flame retardancy UL94V-0
Tracking resistance Min. 175
Operating force
(reference characteristics)
1-pole 2.2 ± 1.2 N
2-pole 4 ± 2.5 N
Contact material AgSnO2 alloy
*Note: Test conditions and are complying with JIS C 6571, EN61058-1 and UL61058-1.
* Except TV rating type

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)