Safety Laser Scanner Type 3 SD3-A1 (Discontinued Products)

I/O Circuit and Wiring diagrams

Connection wiring example with control unit SF-C13

Connection wiring example with control unit SF-C13

Notes:

1): The above diagram is when using manual reset. If automatic reset is used, a reset (RESET) button is not needed.
Settings by software are needed separately.
2): Use a momentary-type switch as the reset (RESET) button.
3): For zone-control inputs (SW1 to 4), use PLC etc. (input time should be 40 ms or less).
Zone No. Control inputs
FP1 FP2 FP3 FP4
1 1 0 0 0
2 0 1 0 0
3 0 0 1 0
4 0 0 0 1
5 1 1 1 0
6 1 1 0 1
7 1 0 1 1
8 0 1 1 1