Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Exclusive Control Unit for Safety Light Curtain SF-C10 > Cautions For Use
Partly Order Discontinued
|
No. | Description | Function |
---|---|---|
① | Emitter side connector | The emitter of SF4B / SF4B-G series is connected. |
② | Receiver side connector | The receiver of SF4B / SF4B-G series is connected. |
③ | Digital indicator (Red) | Lights up or blinks when there is a problem. Lights up when blanking function is enabled. |
④ | Power indicator (Ui) (Green) | Lights up when the power is ON. |
⑤ | Test input indicator (TEST) (Yellow) | Lights up when test input is enabled. Blinks while communication with SFB-HC (optional) handy-controller is in progress. (Excluding SF-C14EX-01) |
⑥ | Muting sensor 1 indicator (MU1) (Orange) | Lights up when muting sensor 1 is ON. |
⑦ | Muting sensor 2 indicator (MU2) (Orange) | Lights up when muting sensor 2 is ON. |
⑧ | Safety output 1 indicator (OUT1) (Green) | Lights up when safety output 1 is ON. |
⑨ | Safety output 2 indicator (OUT2) (Green) | Lights up when safety output 2 is ON. |
⑩ | Safety output 3 indicator (OUT3) (Green) | Lights up when safety output 3 is ON. |
⑪ | Output polarity selection switch | PNP (minus ground) or NPN (plus ground) can be selected. The factory setting is PNP (minus ground). |
⑫ | Auxiliary output 1 indicator (AUX1) (Orange) | Lights up when auxiliary output 1 is ON. |
⑬ | Auxiliary output 2 indicator (AUX2) (Orange) | Lights up when auxiliary output 2 is ON. |
⑭ | Auxiliary output 3 indicator (AUX3) (Orange) | Lights up when auxiliary output 3 is ON. |
⑮ | Interlock 1 indicator (INTER LOCK1) (Yellow) | Lights up when interlock 1 is ON. |
⑯ | Interlock 2 indicator (INTER LOCK2) (Yellow) | Lights up when interlock 2 is ON. |
⑰ | Interlock 3 indicator (INTER LOCK3) (Yellow) | Lights up when interlock 3 is ON. |
SF-C11
Power supply and output line connector : 0.2 to 2.5mm2 (AWG24 to 12)
Signal line connector : 0.2 to 1.5mm2 (AWG24 to 16)
SF-C13
Single wire : ø0.4 to ø1.2mm ø0.016 to ø0.047 in (AWG26 to 16)
Twisted wire (lead wire) : 0.3 to 1.25mm2(AWG22 to 16)
SF-C14EX(-01)
Power supply line connector (A1, A2) : 0.2 to 2.5mm2(AWG24 to 12)
Other connectors ; 0.2 to 1.5mm2 (AWG24 to 16)
Normal operation |
Test input, Override input |
Blown lamp output
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)