Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Optical Touch Switch SW-100 > Specifications
Designation | Optical touch switch | ||
---|---|---|---|
With safeguard | |||
Model No. | SW-101 | SW-111 | |
Sensing method | Thru-beam type photoelectric sensor (2 beam axes) | ||
Applicable standards | CSA 22.2 No.14, CSA 22.2 No.0.8, ANSI / NFPA 79, UL 508, EN 60947-5-2 (EMC only) | ||
Power supply | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Current consumption | 100 mA or less (excluding external connection load) | ||
Outputs | Semiconductor Photo-MOS relay output x 3 • Maximum load current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 100 mA of load current) |
||
Output operation |
Output 1 : When an object is detected (beam is interrupted): OFF / When an object is not detected (beam is received): ON Output 2, 3 : When an object is detected (beam is interrupted): ON / When an object is not detected (beam is received): OFF |
||
Short-circuit protection | Incorporated | ||
Response time | 100 ms or less when an object is detected, 50 ms or less when an object is not detected | ||
Time-out function | Switchable either effective or ineffective by short-circuiting terminals (disabled when short-circuited) | ||
External input | 0 to 1 V or 10 V to +V: Valid (External input indicator lights up), 4 to 6 V or Open: Invalid (External input indicator lights off) | ||
Indicators | Power indicator (POWER) |
Green LED (lights up when the power is ON) | |
Operation indicator (OPE.) |
Green LED (lights up when an object is detected) | ||
External input indicator 1 |
Green LED (lights up when external input 1 is valid) | ||
External input indicator 2 |
Orange LED (lights up when external input 2 is valid) | ||
Fault indicator (FAULT) |
Yellow LED (blinks or lights up when fault occurs) | ||
Protection | IP65 (IEC), TYPE 1 (UL 50) (excluding terminal part) | ||
Ambient temperature | −25 to +50 ℃ −13 to +122 ℉ (No dew condensation or icing allowed), Storage: −30 to +70 ℃ −22 to +158 ℉ |
||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH | ||
Ambient illuminance | Incandescent light: 3,000 Lx or less at the light-receiving face | ||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude in X, Y and Z directions for two hours each | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | ||
Removable-type terminals |
Connector | 3.5 mm 0.138 in pitch, 2-level socket: 12 pins | |
Terminal part | 3.5 mm 0.138 in pitch spring-cage terminals: 6 pins x 2 (FMC1,5/6-ST-3,5GS manufactured by Phoenix Contact) | ||
Cable | 0.2 to 1.5 mm2 [including single wire or ferrule (sleeve)] | ||
Maximum cable length | Up to 20 m 65.617 ft (for cable from 0.2 to 0.3 mm2), Up to 100 m 328.084 ft (for cable from 0.3 to 1.5 mm2) | ||
Material | Enclosure: Polycarbonate, Polyester, O-ring: Silicone rubber, Mounting nut: PBT, Mounting packing: Silicone rubber | ||
Weight | Net weight: 130 g approx., Gross weight: 200 g approx. | Net weight: 150 g approx., Gross weight: 220 g approx. |
Note:
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)