Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > UV-Curing Systems > UV-Curing Systems > Aicure UJ30/35 LED Spot Type UV Curing Systems(Discontinued Products) > Specifications
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
|
UJ30 (Standard model) | UJ35 (High performance model) | ||
---|---|---|---|
Controller Part No. | ANUJ3000 | ANUJ3500 | |
Connectable heads | 1to 4 heads | ||
Connectable UV sensor | Not compatible | Compatible | |
UV irradiation | One pattern irradiation in simple mode The heads are either collectively or individually controlled. |
One pattern in simple mode and programmed pattern 0irradiation (up to 7 patterns with up to 10 steps) The heads are either collectively or individually controlled. | |
Pattern switching | None (1 type) | Switchable (8 types) | |
Intensity/irradiation control | Digital intensity and irradiation control manual or timer control Manual/timer control (0.1 to 99.9 sec., 100 to 999 sec.) Auto-tuning function using the UV sensor (for UJ35 only) Specifications of UV sensor: [Temperature characteristic: ±5 % F.S. (+5 to +35℃ +41 to +95℉)/ Repeat accuracy: ±1 % (+25℃ +77℉)] |
||
Setting/Operation | Setting by the operation switches and power-on/off by a key switch | Setting by the operation switches, power-on/off by a key switch and RS-232C (UJ35 setup tool) |
|
Display | 7-segment display | ||
Cooling system | Natural cooling (without a fan) | ||
External control | Method | Parallel I/O | RS-232C, Parallel I/O |
External input | Individual irradiation input, irradiation stop input, interlock, full-irradiation input, pattern switching (for UJ35 only) |
||
External output | READY signal, error signal, alarm output, BUSY output (each head separately), +5 V output (for indicator) |
||
Operating voltage | With AC adapter: 100 - 240 V AC (±10 %) 50 / 60 Hz 60 VA (at 100 V AC) | ||
Operating ambient temperature / Operating ambient humidity |
0 to +35℃ +32 to +95℉ / 30 to 85 % RH (No dew condensation allowed) | ||
Storage ambient temperature / Storage ambient humidity |
–10 to +60℃ +14 to +140℉ / 30 to 85 % RH (No dew condensation or icing allowed) | ||
Accessories | AC adapter and Key | ||
Weight | 1,180 g approx. (Controller: 940 g approx., AC adapter: 240 g approx.) | 1,200 g approx. (Controller: 960 g approx., AC adapter: 240 g approx.) |
365 nm wavelength high-output head |
Head model No. | ANUJ6186 | ||||||
---|---|---|---|---|---|---|---|---|
Compatible lens | Spot diameter | ø3 mm ø0.118 in |
ø4 mm ø0.157 in |
ø6 mm ø0.236 in |
ø8 mm ø0.315 in |
ø10 mm ø0.394 in |
Protective glass (Note2) |
|
Lens model No. | ANUJ6423 | ANUJ6424 | ANUJ6426 | ANUJ6428 | ANUJ6420 | ANUJ6430 | ||
UV intensity (mW/cm2) (Note1) |
17,200 | 14,940 | 7,560 | 4,450 | 1,360 | 530 | ||
Irradiation distance | 8 mm 0.315 in |
10 mm 0.394 in |
15 mm 0.591 in |
20 mm 0.787 in |
30 mm 1.181 in |
10 mm 0.394 in |
||
365 nm wavelength standard type |
Head model No. | ANUJ6180 | ||||||
Compatible lens | Spot diameter | ø3 mm ø0.118 in |
ø4 mm ø0.157 in |
ø6 mm ø0.236 in |
ø8 mm ø0.315 in |
ø10 mm ø0.394 in |
Protective glass (Note2) |
|
Lens model No. | ANUJ6423 | ANUJ6424 | ANUJ6426 | ANUJ6428 | ANUJ6420 | ANUJ6430 | ||
UV intensity (mW/cm2) (Note1) |
12,500 | 10,600 | 4,720 | 2,500 | 580 | 300 | ||
Irradiation distance | 10 mm 0.394 in |
12 mm 0.472 in |
20 mm 0.787 in |
25 mm 0.984 in |
30 mm 1.181 in |
10 mm 0.394 in |
||
385 nm wavelength high-output head |
Head model No. | ANUJ6188 | ||||||
Compatible lens | Spot diameter | ø3 mm ø0.118 in |
ø4 mm ø0.157 in |
ø6 mm ø0.236 in |
ø8 mm ø0.315 in |
ø10 mm ø0.394 in |
Protective glass (Note2) |
|
Lens model No. | ANUJ6423 | ANUJ6424 | ANUJ6426 | ANUJ6428 | ANUJ6420 | ANUJ6430 | ||
UV intensity (mW/cm2) (Note1) |
19,500 | 16,920 | 8,680 | 4,750 | 1,400 | 580 | ||
Irradiation distance | 8 mm 0.315 in |
10 mm 0.394 in |
15 mm 0.591 in |
20 mm 0.787 in |
30 mm 1.181 in |
10 mm 0.394 in |
||
385 nm wavelength standard type |
Head model No. | ANUJ6184 | ||||||
Compatible lens | Spot diameter | ø3 mm ø0.118 in |
ø4 mm ø0.157 in |
ø6 mm ø0.236 in |
ø8 mm ø0.315 in |
ø10 mm ø0.394 in |
Protective glass (Note2) |
|
Lens model No. | ANUJ6423 | ANUJ6424 | ANUJ6426 | ANUJ6428 | ANUJ6420 | ANUJ6430 | ||
UV intensity (mW/cm2) (Note1) |
14,700 | 11,700 | 5,800 | 2,790 | 590 | 330 | ||
Irradiation distance | 10 mm 0.394 in |
12 mm 0.472 in |
15 mm 0.591 in |
20 mm 0.787 in |
30 mm 1.181 in |
10 mm 0.394 in |
||
405 nm wavelength high-output head |
Head model No. | ANUJ6189 | ||||||
Compatible lens | Spot diameter | ø3 mm ø0.118 in |
ø4 mm ø0.157 in |
ø6 mm ø0.236 in |
ø8 mm ø0.315 in |
ø10 mm ø0.394 in |
Protective glass (Note2) |
|
Lens model No. | ANUJ6423 | ANUJ6424 | ANUJ6426 | ANUJ6428 | ANUJ6420 | ANUJ6430 | ||
UV intensity (mW/cm2) (Note1) |
20,900 | 17,800 | 9,190 | 5,450 | 1,790 | 810 | ||
Irradiation distance | 8 mm 0.315 in |
10 mm 0.394 in |
15 mm 0.591 in |
20 mm 0.787 in |
30 mm 1.181 in |
10 mm 0.394 in |
||
405 nm wavelength standard type |
Head model No. | ANUJ6187 | ||||||
Compatible lens | Spot diameter | ø3 mm ø0.118 in |
ø4 mm ø0.157 in |
ø6 mm ø0.236 in |
ø8 mm ø0.315 in |
ø10 mm ø0.394 in |
Protective glass (Note2) |
|
Lens model No. | ANUJ6423 | ANUJ6424 | ANUJ6426 | ANUJ6428 | ANUJ6420 | ANUJ6430 | ||
UV intensity (mW/cm2) (Note1) |
15,500 | 12,600 | 5,730 | 3,150 | 890 | 440 | ||
Irradiation distance | 10 mm 0.394 in |
12 mm 0.472 in |
20 mm 0.787 in |
25 mm 0.984 in |
30 mm 1.181 in |
10 mm 0.394 in |
||
Common item | Light source | Class 3B LED product (JIS C6802:2005) Risk group 3 (ANUJ6189 / ANUJ6187: Risk group 2) (IEC 62471) | ||||||
Estimated light source life (Note3) |
20,000 hours (when the LED temperature inside the head is 60℃ 140℉) | |||||||
Cable length | 0.2 m 0.656 ft A connection cable is required to connect the high-output head to a UJ series controller. |
|||||||
Ambient operating temperature / ambient operating humidity |
+5 to +35℃ +41 to +95℉ / 30 to 85 % RH (No dew condensation allowed) | |||||||
Storage temperature and humidity | –10 to +60℃ +14 to +140℉ / 30 to 85 % RH (No dew condensation or icing allowed) |
Note:1) | The values were measured using a UJ30/35 illuminometer with ø1 mm ø0.039 in sensor hole when the high-output heads were fixed to the attachment, the ambient temperature was maintained at 25℃ 77℉ by the UJ30/35, and they were turned on with 100% output (initial value: based on Panasonic's reference measurement method). Since the LED elements show illumination intensity fluctuations, the actual UV intensity may be more than 20% higher. |
---|---|
2) | It is recommended that protective glass (ANUJ6430) be used to protect the head-side lens from contamination when the high-output head is used without a lens. For further information about protective glass, contact our sales office. |
3) | The value is not a guaranteed value. |
Standard head (Note1) | Product No. | ANUJ6172 | |||||
---|---|---|---|---|---|---|---|
Cable length | 1.9m 6.234ft (ANUJ6172), directly connectable to the controller | ||||||
Compatible lens | Spot diameter | ø3mm 0.118in | ø4mm 0.157in | ø6mm 0.236in | ø8mm 0.315in | ø10mm 0.394in | |
Product No. | ANUJ 6423 | ANUJ 6424 | ANUJ 6426 | ANUJ 6428 | ANUJ 6420 | ||
Irradiation intensity (mW/cm2) (Note2) | 9,300 | 7,900 | 3,600 | 1,700 | 640 | ||
Irradiation distance | 10mm 0.394in | 12mm 0.472in | 20mm 0.787in | 25mm 0.984in | 30mm 1.181in | ||
Common item | Light source | Class 3B LED product | |||||
Estimated lamp life (Note3) | 20,000 hours (When the temperature of the LED in the head is 60℃ 140℉ or less.) | ||||||
Operating temperature and humidity | +5 to +35℃+41 to +95℉ , 30 to 85% RH (No condensation at 25℃ 77℉ ) | ||||||
Storage temperature and humidity | -10 to +60℃+14 to +140℉ , 30 to 85% RH (No condensation at 25℃ 77℉ ) |
Note:1) | The cable for standard heads is supplied in a fixed length. |
---|---|
2) | When being fixed to the metal attachment, the ambient temperature is 25℃ 77℉ , and the intensity is set to 100% (initial value). |
3) | Not a guarateed value. |
4) | ANUJ6170 series except ANUJ6172 have been discontinued on June 30, 2014. If the specifications of ANUJ6170 series are needed, please refer to the page of the heads (ANuUJ6170 series)(discontinued products). |
|
|
|
|||||||||
|
|
|
|||||||||
INPUT | OUTPUT | |||
---|---|---|---|---|
Terminal No. | Signal | Terminal No. | Signal | |
1 | START1 | 13 | READY-All | |
2 | START2 | 14 | READY / BUSY1 (Note 2) | |
3 | START3 | 15 | READY / BUSY2 (Note 2) | |
4 | START4 | 16 | READY / BUSY3 (Note 2) | |
5 | TYPE Chg1 (Note 1) | 17 | READY / BUSY4 (Note 2) | |
6 | TYPE Chg2 (Note 1) | 19 | ERROR | |
7 | TYPE Chg3 (Note 1) | 20 | ALARM | |
8 | UV CHECK (Note 1) | 21 | COM | |
9 | STOP | 22 | COM | |
10 | START-All | 23 | FG | |
11 | INTERLOCK (Note 3) | 24 | +5 V DC | |
12 | COM | 25 | COM |
Notes: 1) | Nos. 5 / 6 / 7 / 8 (Type-Chg 1 / 2 / 3 and UV-CHECK) are functions available UJ35 only. These terminals for UJ30 are spare. |
---|---|
2) | The READY / BUSY switching of Nos. 14 / 15 / 16 / 17 is performed on the UJ30 / UJ35 controller. |
3) | At shipment, for B-contact (allows irradiation when ON), No.11 (INTERLOCK) is connected to No.12 (COM) by a short-circuit line. |