Business > Industrial Devices > Automation Controls Top > FP7 Multi-wire link unit > AFP7MW
*Photo may vary from actual product.
Product Number | AFP7MW |
Part Number | AFP7MW |
Product | Multi-wire link unit |
Product name | FP7 Multi-wire link unit |
As of May 03, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | AFP7MW |
Part Number | AFP7MW |
Features | Use for additional connection or replacement in existing multi-wire link networks. Note: Some functions of the FP7 are not compatible with conventional products. |
Item | Specifications |
---|---|
Mode | W mode, W2 mode, F mode |
Communication method | W mode, W2 mode : Token bus method F mode : Polling method |
Transmission method | Baseband transmission method |
Transmission speed | W mode : 500 kbits/sec. W2 mode : 500 kbits/sec., 250 kbits/sec. F mode : 500 kbits/sec. |
Transmission distance | W mode : Extendable to 800 m 2,624.672 ft W2 mode : Extendable to 800 m 2,624.672 ft(500 kbits/sec.), Extendable to 1,200 m 3,937.008 ft(250 kbits/sec.) F mode : Extendable to 700 m 2,296.588 ft |
Number of connectable stations | W mode, W2 mode : Max. 32 stations F mode : 1 master station + Max. 32 slave stations |
Transmission error check | CRC (Cyclic Redundancy Check) system |
Synchronous method | Start-stop synchronization |
Interface | RS485 compatible |
Transmission cable | W mode, W2 mode : Twisted-pair cable F mode : Twisted-pair cable, VCTF cable |
RAS function | Hardware self-diagnosis function |
Item | Specifications |
---|---|
Ambient temperature | 0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉ |
Ambient humidity | 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation) |
Vibration resistance | 5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions |
Shock resistance | 147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2) |
Noise immunity | 1,000 V [p-p] with pulse width 50 ns and 1 μs (using a noise simulator) |
Operating condition | Free from corrosive gasses and excessive dust |
Item | Specifications |
---|---|
Current consumption | 100 mA or less |
Net weight | 100 g approx. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)