Product Number | HE1aN-Q-AC100V |
Part Number | AHE1264 |
Product name | HE Relays |
Features | TV-10/TV-15 rated, 1 Form A 30 A, 2 Form A 25 A, Power relays |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
As of May 10, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | HE1aN-Q-AC100V |
Part Number | AHE1264 |
Protective construction | Dust Cover |
Operating function | Single side stable |
Terminal shape | Tab terminal (TM type) |
Coil type | AC type (AC coil) |
Insulation distance | Min. 8 mm |
Contact gap | Min. 3 mm (reference value) |
Packing style | Carton |
Standard packing Carton (pieces) |
20 |
Standard packing Case (pieces) |
100 |
Item | Specifications |
---|---|
Rated coil voltage | 100/120 V AC |
Operate voltage (at20°C) | Max. 70 V AC (Initial) |
Release voltage (at20°C) | Min. 18 V AC (Initial) |
Rated operating current [±10%] (at 20°C) | 18.7 to 22.1 mA |
Rated operating power | 1.9 VA to 2.7 VA |
Max. allowable voltage | 110% V of rated coil voltage (at 20°C) |
Item | Specifications |
---|---|
Contact arrangement | 1 Form A |
Contact shape | Single |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) |
Contact material | AgSnO2 type |
Contact rating (resistive load) | 30 A 277 V AC |
Max. switching power (resistive load) | 8,310 VA |
Max. switching voltage | 277 V AC, 30 V DC |
Max. switching current | 30 A (AC) |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 10,000 V |
Operate time (initial) (at 20°C) | Max. 30 ms at rated coil voltage (without bounce) |
Release time (initial) (at 20°C) | Max. 30 ms at rated coil voltage (without bounce) |
Shock resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Shock resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical life | Min. 5x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 90 g |
Item | Specifications |
---|---|
Resistive load | [switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC |
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)