Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > HE-S Relays > Part Number > AHES3190Q
*Photo may vary from actual product.
Product Number | AHES3190Q |
Part Number | AHES3190Q |
Product name | HE-S Relays |
Features | Compact size 2a and 2a1b 40 A power relays for energy management and industrial equipment |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
As of May 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | AHES3190Q |
Part Number | AHES3190Q |
Protective construction | Flux-resistant |
Operating function | Single side stable |
Terminal shape | PC board terminal |
Contact rating type | High capacity type |
Electrical life type | Standard type |
Contact gap | 3.2 mm |
Standard packing Carton (pieces) |
25 |
Standard packing Case (pieces) |
100 |
Item | Specifications |
---|---|
Rated coil voltage | 6 V DC |
Operate voltage (at20°C) | Max. 75% V of rated coil voltage (Initial) |
Release voltage (at20°C) | Min. 5% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20°C) | 313 mA |
Coil resistance [±10%] (at 20°C) | 19.1 Ω |
Rated operating power | 1,880 mW Holding: 170 mW |
Max. allowable voltage | (at 55°C) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours |
Item | Specifications |
---|---|
Contact arrangement | 2 Form A |
Contact shape | Single |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) |
Contact material | AgSnO2 type |
Contact rating (resistive load) | 40 A 277 V AC, 5 A 110 V DC |
Max. switching power (resistive load) | 11,080 VA, 550 W |
Max. switching voltage | 480 V AC, 110 V DC |
Max. switching current | 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Short current (A contact, Initial) | Max. 1,000 A 1 ms, 3 times (Reference value) |
Dielectric strength (initial) : Between open contacts | Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA) |
Dielectric strength (Initial) : Between contact sets | Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) |
Dielectric strength : Between Form A contact and Form B contact | 5,000 Vrms for 1min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 10,000 V (Between Form A contact and coil) |
Coil holding voltage | 30 to 110% V (at -40 to +55°C), 30 to 60% V (at +55 to +85°C) |
Operate time (initial) (at 20°C) | Max. 30 ms at rated coil voltage (without bounce) |
Release time (initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
Shock resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Shock resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical life | Min. 5x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +70°C (Max. carrying current 40 A) Ambient temperature: -40 to +85°C (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx.64g |
Item | Specifications |
---|---|
Resistive load | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC |
Inductive load | [switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosφ = 0.8) |
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)