[Notification of CAD Data Download Issue]
We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > ER-F12S
*Photo may vary from actual product.
Product Number | ER-F12S |
Part Number | ER-F12S |
Product | Fan Type Ionizer |
Details | Low-volume fan type |
Product name | Fan Type Ionizer ER-F |
Item | Specifications |
---|---|
Product Number | ER-F12S |
Part Number | ER-F12S |
Charge removal time | 1.5 sec. approx. (plus or minus1,000 V to plus or minus100 V) (Note) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. |
Ion balance | plus or minus10 V or less (Note) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. |
Supply voltage | 24 V DC plus or minus10% |
Current consumption | 400 mA or less |
Discharge method | High-frequency AC method |
Discharge output voltage | plus or minus 2 kV approx. |
Max. fan speed | 4.0 m/s (Note) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. |
Max. fan volume | 2.50 m3/min |
Main functions | Error output, Discharge halt input |
Indicators | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) |
Ozone generation | 0.04 ppm or less (Note) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. |
Ambient temperature | 0 to +50degrees +32 to +122degrees Fahrenheit (No dew condensation) , Storage: –10 to +65degrees +14 to +149degrees Fahrenheit |
Ambient humidity | 35 to 65% RH (No dew condensation) , Storage: 35 to 65% RH |
Grounding method | C (capacitor) grounding |
Material | Enclosure: ABS, Louver: ABS, Discharge needle unit: PBT, Discharge needle: Tungsten, Bracket: SPHC |
Weight | Main unit: 790 g approx. |
Accessories | Straight louver: 1 pc. (Note), Angle louver: 1 pc., Caution label: 1 set, Rubber cushion: 1 pc. (Note) The discharge needle unit is loaded on the straight louver before shipment. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])