[Notification of CAD Data Download Issue]
We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Ultra-slim Safety door switch SG-A1 > Part Number > SG-A1-12-5
*Photo may vary from actual product.
Product Number | SG-A1-12-5 |
Part Number | SG-A1-12-5 |
Product | Ultra-slim Safety door switch |
Product name | Ultra-slim Safety door switch SG-A1 |
As of May 18, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Number | SG-A1-12-5 | |||||||||||||||||||||||||||||||
Part Number | SG-A1-12-5 | |||||||||||||||||||||||||||||||
Door monitor contacts | 2NC+1NO | |||||||||||||||||||||||||||||||
Cable length | 5 m 16.404 ft | |||||||||||||||||||||||||||||||
Applicable standards | EN 60947-5-1, GS-ET-15 | |||||||||||||||||||||||||||||||
Applicable standards : Standards for use | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 | |||||||||||||||||||||||||||||||
Applicable regulations | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] | |||||||||||||||||||||||||||||||
Operating condition : Ambient temperature | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ |
|||||||||||||||||||||||||||||||
Operating condition : Ambient humidity | 45 to 85 % RH | |||||||||||||||||||||||||||||||
Operating condition : Pollution degree | 3 (Inside 2) | |||||||||||||||||||||||||||||||
Operating condition : Altitude | 2,000 m 6,561.68 ft max. | |||||||||||||||||||||||||||||||
Impulse withstand voltage (Uimp) | 4 kV | |||||||||||||||||||||||||||||||
Rated insulation voltage (Ui) | 300 V | |||||||||||||||||||||||||||||||
Thermal current (Ith) | 2.5 A | |||||||||||||||||||||||||||||||
Rated operational voltage (Ue) / Rated operational current (Ie) |
|
|||||||||||||||||||||||||||||||
Electric shock protection class | Class II (IEC 61140), 回(double insulated) | |||||||||||||||||||||||||||||||
Protection | IP 67 (IEC 60529) | |||||||||||||||||||||||||||||||
Shock resistance | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 |
|||||||||||||||||||||||||||||||
Vibration resistance | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in |
|||||||||||||||||||||||||||||||
Operating frequency | 1,200 operations/hour | |||||||||||||||||||||||||||||||
Actuator operating speed | 0.05 to 1.0 m/sec. | |||||||||||||||||||||||||||||||
B10D | 2,000,000 (ISO 13849-1 Annex C Table C.1) |
|||||||||||||||||||||||||||||||
Mechanical durability | 1,000,000 operations min. (GS-ET-15) | |||||||||||||||||||||||||||||||
Electrical durability | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) |
|||||||||||||||||||||||||||||||
Direct opening travel | 8 mm 0.315 in min. | |||||||||||||||||||||||||||||||
Direct opening force | 60 N min. | |||||||||||||||||||||||||||||||
Contact resistance | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) |
|||||||||||||||||||||||||||||||
Short-circuit protective device | Use 250 V / 10 A fast acting type fuse | |||||||||||||||||||||||||||||||
Conditional short-circuit current | 50 A (250 V) | |||||||||||||||||||||||||||||||
Material | Enclosure : PA66 | |||||||||||||||||||||||||||||||
Cable | UL style 2464, No.20 AWG 6-core | |||||||||||||||||||||||||||||||
Weight | Approx. 420 g |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)