【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Human Machine Interface > Human Machine Interface > Programmable Display GT32-E
Discontinuation plan
|
|
Outdoor use made possible by significantly improved environmental resistance and visibility
|
UL/C-UL
, CE
, Korean KC
, UKCA
Approved
UL : Excluding some models
CE : Excluding some models
Korean KC : Excluding some models
UKCA : Excluding some models
5.7 inch, 4,096 colors TFT color LCD equipped with long life LED backlight
Great visibility even in bright environments is possible thanks to use of a TFT LCD with contrast ratio of 500 : 1.
5.7 inch, 16-gray scale TFT monochrome LCD equipped with long life LED backlight
Through use of a TFT LCD with contrast ratio of 400 : 1, the "e;deep black"e; on a bright display means incredible visibility even in bright environments.
Integrated USB Interface
Transformer-isolated power supply |
The wide operating temperature range allows for use in various environments.(−20 to +55 ℃ −4 to +131 ℉ when horizontally installed, vertically installed in a portrait orientation, upside down installed and when using battery) |
Resistant to UV Rays!The two-layer front protection sheet deduces UV rays in two-stage. |
High waterproof performance allows for use in environments exposed to splashing water.The front panel has a protective structure rated IP67. |
High visibility display even in bright environments!High in brightness and contrast and anti-glare coating provides exceptional viewing characteristics. |
Same resolution [320 (W) × 240 (H) dots] as the 5.7 inch modelScreen data of GT32-E can be used on the smaller display. |
・High contrast TFT LCD:Achieved higher contrast and visibility.
・High brightness backlight: Achieved greater brightness and visibility than the conventional model.
The monochrome type, in particular, is greater brightness than the conventional model and is way easier to view in bright environments thanks to the “deep black”.
|
|
|
|
・The front sheet is made of a material that does not transmit UV rays.
The LCD and touch panel can be protected from deterioration.
・The front panel has a protective structure rated IP67.
Safe to use outdoors or in a location exposed to splashing water.
・Added protection has been applied to the rear of the unit for a more rugged overall construction.
・Usable in a range of -20℃ to +60 ℃ -4℉ to +140℉
(-20℃ to +55℃ -4℉ to +131℉ when horizontally installed, vertically installed in a portrait orientation, upside down installed and when using battery.)
・The TFT LCD can quickly switch screens even at a low temperature.
・The life of the LED backlight does not decrease even at a low power consumption.
・It is not necessary to prepare a heater for use at a low temperature.
・Compact color type (GT03T-E): 3.1 W or less
・Compact monochrome type (GT03M-E): 1.9 W or less
・Color type (GT32T-E): 7.2 W or less
・Monochrome type (GT32M-E): 4.8 W or less
As small-size touch panels have significantly improved their image quality, easy to read displays with sharp characters are no longer special features these days.
Instead, programmable displays will evolve with maximum "user-friendliness" in various applications with PCs or other devices.
As shown below, our touch panels exchange and store data using SD memory card, data for many applications.
It is possible to modify PLC ladder programs as well as the GT screen programs by using an SD / SDHC memory card.
SD / SDHC memory card enables everyone to easily modify programs.
* Our FP series, excluding FP7 / FP0H.
Log and other data saved on a SD memory card inserted into the GT’s onboard SD memory card slot can now be sent to a PC using a USB connection.
|
Capable of automatically collecting electrical power readings of Eco-POWER METERS and displaying them in a real time graph, allowing users to take quick actions for solutions.
● The GT unit can collect data, such as electrical power on an SD / SDHC memory card, and display the log data in a real time graph.
You can make data “Visualization” without using a PC as a display or Data logger for collecting data.
● One bar graph has a maximum of eight bars and can be combined with line graphs.
● The following three conditions can be selected to trigger an operation to save log data.
(1) Specified time (2) Specified cycle (1 sec. to 24 hrs.) (3) Specified condition
● Large volumes of data can be saved on an SD / SDHC memory card, which can be carried with you.
For high-mix production, recipe data up to 64 types and 4,096 devices in total, can be easily set on a PC. The created recipe data is saved on an SD / SDHC memory card, and the specified data can be written or read from a PLC.
The alarm history data stored in the GT built-in memory can be saved on an SD / SDHC memory card, making it possible to easily control problems on a PC.
GT series displays use an analog-touch panel where locations of parts and characters can be adjusted in increments of one dot. The adoption of the Windows® font has widened the character size selection (10 to 240 dots), making the screen design more flexible. |
One bar graph has a maximum of eight bars and can be combined with line graphs.
The unit can display screens in portrait orientation and can therefore be installed in narrow spaces, expanding system design possibilities and contributing to size reduction.
The portrait display is also ideal for slim equipment without enough space to install a display.
A flowing message of up to 64 characters (two-byte) can be displayed at the bottom of the screen. (128 messages)
Multiple operations are possible. For example, screens can be switched by setting multiple values.
3D-design buttons with higher visibility and operability are available. |
*Excluding FP7
Five convenient features of GT series for improved compatibility with our FP series of PLCs
[1] | Device monitor (Display and change values of FP series devices. Three different modes available.) (1)Easy monitor mode:Use this mode when you want to monitor something. Display is continuous when one device is specified and the device can be changed. (2)Entry monitor mode:Use this mode when you want to monitor multiple devices. You can register devices you want to display one-by-one and you can change them. (3)Forced on / off mode:Use this mode feature to forcibly turn output on and off. You can set devices one-by-one for which you want to control output. |
---|---|
[2] | System register monitor (Display and change of system register values.)(Excluding FP0H)) You can specify the system register number, display the value, and change it. |
[3] | Shared memory monitor (Display shared memory values.) You can specify the slot number, bank number and address, and display the value. You cannot change the value. |
[4] | Error monitor (Display an error occurring in the FP series PLC.) You can display the self-diagnostic result, error code and error flag, and you can even clear the error. |
[5] | Password setting (Set the password to protect FP series program reading and writing functions.) Password registration and clearing is possible for the FP series password protection function. |
|
|
Password protection and operation security functions protect the data asset in the display unit and control the authorization for operation.
Password protection function
The screen data upload operation can be restricted by using passwords to protect the data asset in the display unit.
Operation security function
Up to 64 operators can set individual passwords, and up to 16 levels of restrictions can be set on displays and operations for each part. The registered users and passwords can be changed on the display unit.
This function allows operators to simultaneously carry out the transfer of screen data of a GT series display and the debugging of our FP series PLC connected to the display.
Conventionally, screens were created for each language. With this new language switching function, data can be registered in multiple languages (up to 16) for each part. The characters can be easily edited with Microsoft Excel® and then imported. |
This function modifies the PLC data or turns bits on/off according to the PLC status or the screen No. Now four arithmetic operations between devices are also possible. |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)