【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Ultra High-speed・High-precision Laser Displacement Sensor HL-C2
Discontinuation plan
|
March 31, 2025 |
|
|
I/O Circuit and Wiring diagrams
Terminal arrangement
|
Terminal |
Function |
NPN |
PNP |
(V)1 |
Analog voltage output (for OUT1) |
AGND |
Analog ground |
(I)1 |
Analog current output (for OUT1) |
(V)2 |
Analog voltage output (for OUT2) |
AGND |
Analog ground |
(I)2 |
Analog current output (for OUT2) |
LSRA |
Laser control input (for Head A) Laser stop during short circuit |
LSRB |
Laser control input (for Head B) Laser stop during short circuit |
(–) |
Common (–) |
IL |
IL- |
Remote interlock Laser stop when opened. |
(–) |
IL+ |
Remote interlock common |
|
|
Terminal |
Function |
NPN |
PNP |
ZS2 |
Zero set input (for OUT2) ON during short circuit (Note 1) |
TM2 |
Timing input (for OUT2) ON during short circuit |
RS2 |
Reset input (for OUT2) ON during short circuit |
(–) |
Common (–) |
AL2 |
Alarm output (for OUT2) |
ST2 |
Strobe output (for OUT2) |
HI2 |
Judgment HI output (for OUT2) |
GO2 |
Judgment GO output (for OUT2) |
LO2 |
Judgment LO output (for OUT2) |
• |
Reserved terminal (Note 2) |
(–) |
(+) |
Common (–) / Common (+) |
M0 |
Memory change (16 ways) |
M1 |
M2 |
M3 |
(–) |
Common (–) |
Notes:
1) |
Turn off the terminal in case short circuit lasts for more than one second. |
2) |
Do not connect anything to the reserved terminals; they are connected to the internal circuit. |
|
|
Terminal |
Function |
NPN |
PNP |
ZS1 |
Zero set input (for OUT1) ON during short circuit (Note 1) |
TM1 |
Timing input (for OUT1) ON during short circuit |
RS1 |
Reset input (for OUT1) ON during short circuit |
• |
Reserved terminal |
• |
Reserved terminal |
(–) |
Common (–) |
AL1 |
Alarm output (for OUT1) |
ST1 |
Strobe output (for OUT1) |
HI1 |
Judgment HI output (for OUT1) |
GO1 |
Judgment GO output (for OUT1) |
LO1 |
Judgment LO output (for OUT1) |
• |
Reserved terminal (Note 2) |
(–) |
(+) |
Common (–) / Common (+) |
24V |
24 V DC input for power supply |
0V |
Power supply ground 0 V |
FG |
Frame ground |
Notes:
1) |
Turn off the terminal in case short circuit lasts for more than one second. |
2) |
Do not connect anything to the reserved terminals; they are connected to the internal circuit. |
|
NPN output type
No voltage input or NPN transistor open
collector output |
|
|
|
Non-voltage
input |
|
|
PNP output type
No voltage input or NPN transistor open
collector output |
|
|
|
Non-voltage
input |
|
|
Analog output (Common in NPN output type and PNP output type)
Notes: 1) Do not short-circuit analog output terminals or apply voltage to them.
2) Use shielded wires for analog outputs.
Return to top
Return to top