Type | Compound pressure | Positive pressure | |||
---|---|---|---|---|---|
-0.1 to 1 MPa type | 1 MPa type | 3.5 MPa type | 10 MPa type | 50 MPa type | |
Model No. | DPH-L113V | DPH-L113 | DPH-L133 | DPH-L114 | DPH-L154 |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||||
Type of pressure | Sealed gauge pressure (Note 4) | ||||
Rated pressure range | -0.1 to +1 MPa | 0 to +1 MPa | 0 to +3.5 MPa | 0 to +10 MPa | 0 to +50 MPa |
Pressure withstandability | 2 MPa | 2 MPa | 7 MPa | 20 MPa | 75 MPa |
Applicable fluid | Gases and fluids that do not corrode stainless steel SUS630, SUS304, or SUSXM7 | ||||
Supply voltage | 9 to 36 V DC [9 to 32 V DC when using the attached connector (e-CON)] |
||||
Current consumption | 20 mA or less | ||||
Analog voltage output | Output voltage: 1 to 5 V DC (over rated pressure range) Accuracy: ±1.0 % F.S. (at 23 ±2 ℃ +73.4 ±35 ℉) ±2.0 % F.S. (at -20 to 70 ℃ -4 to +158 ℉) (including linearity, hysteresis and repeatability) |
Output voltage: 1 to 5 V DC (over rated pressure range) Accuracy: ±1.0 % F.S. (at 23 ±2 ℃ +73.4 ±35 ℉) ±2.0 % F.S. (at -20 to 125 ℃ -4 to +257 ℉) (including linearity, hysteresis and repeatability) |
|||
Response time | 1 ms or less | ||||
Protection | IP67 (IEC) | ||||
Ambient temperature | -20 to +70 ℃ -4 to +158 ℉ (No dew condensation or icing allowed), Storage: -30 to +70℃ -22 to +158 ℉ |
-20 to +80 ℃ (Pressure port: -20 to +125 ℃ -4 to +257 ℉, No dew condensation or icing allowed), Storage: -30 to +100 ℃ -22 to +212 ℉ [e-CON connector (accesory): -20 to +75 ℃ -4 to +167 ℉ (Storage: -30 to +75 ℃ -22 to +167 ℉)] |
|||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Medium temperature range | -20 to +70 ℃ -4 to +158 ℉ | -20 to +125 ℃ -4 to +257 ℉ | |||
Voltage withstandability | 150 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 100 MΩ, or more, with 50 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 2,000 Hz frequency, acceleration 200 m/s2, in X direction for four hours, in Y and Z directions for two hours each (Note 5) | ||||
Shock resistance | 1,000 m/s2 acceleration in X, Y and Z directions three times each | ||||
Grounding method | Capacitor earth (Enclosure-supply terminal) | ||||
Pressure port | R1/4 male thread (throttle embeded) | ||||
Material | Diaphragm: Stainless steel (SUS603), Pressure port: Stainless steel (SUS304), Throttle: Stainless steel (SUSXM7) | ||||
Connecting method | Connector | ||||
Cable | 0.2 mm2 3-core heat resistant cabtyre cable 2 m 3.562 ft long | ||||
Cable extension | Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable. | ||||
Weight | Net weight: 100 g approx., Gross weight: 150 g approx. | ||||
Accessory | Connector (e-CON): 1 pc. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2) | The sensor head can be used independently. |
3) | Oil is used in the factory inspection process for models DPH-L114 and DPH-L154. There may be some residual oil inside the pressure port. |
4) | The sensor’s internal mechanism is sealed based on an air pressure of 1,013 hPa. |
5) | The X, Y, and Z directions are defined as follows: |
NPN output | DPC-L101 | |||
---|---|---|---|---|
PNP output | DPC-L101-P | |||
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | |||
Applicable sensor head | DPH-L113V | DPH-L113 | DPH-L133 | |
Rated pressure range | -0.1 to +1 MPa | 0 to +1 MPa | 0 to +3.5 MPa | |
Set pressure range | -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm2 -11.77 to +11.77 bar -170.6 to +170.6 psi |
-1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm2 -10.70 to +10.70 bar -155.2 to +155.2 psi |
-3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm2 -37.4 to +37.4 bar -542 to +542 psi |
|
Set resolution | 0.001 MPa | 0.001 MPa | 0.01 MPa | |
Display | 4 digits +4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
|||
Displayable pressure range | -0.155 to +1.022 MPa -1.58 to +10.42 kgf/cm2 -1.55 to +10.22 bar -22.4 to +148.2 psi |
-0.050 to +1.020 MPa -0.51 to +10.40 kgf/cm2 -0.50 to +10.20 bar -7.2 to +148.0 psi |
-0.17 to +3.57 MPa -1.7 to +36.4 kgf/cm2 -1.7 to +35.7 bar -24 to +518 psi |
|
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | |||
Power consumption | Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD): 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL): 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current |
|||
Comparative outputs (Comparative output 1, 2) |
<NPN output type> NPN open-collector transistor (2 outputs) • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) <PNP output type> PNP open-collector transistor (2 outputs) • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and +V) • Residual voltage: 1 V or less (at 50 mA source current) |
|||
Output operation | NO / NC, selectable by key operation | |||
Output modes | EASY mode / Hysteresis mode / Window comparator mode | |||
Hysteresis | Minimum 1 digit (variable) (however, 2 digits when using psi unit) | |||
Repeatability | Within ±0.2 % F.S. | |||
Response time | 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation | |||
Short-circuit protection | Incorporated | |||
Analog output | <Analog voltage output> • Output current: 1 to 5 V DC • Zero point: within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V) • Span: within 4 V ±0.5 % F.S. • Linearity: within ±0.1 % F.S. • Output impedance: 1 kΩ approx. <Analog current output> • Output current: 4 to 20 mA • Zero point: within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V) • Span: within 16 mA ±1.5 % F.S. • Linearity: within ±0.1 % F.S. • Load resistance: 250 Ω (max.) |
|||
Inputs | Sensor head input | Input voltage range: 1 to 5 V DC (over rated pressure range) | ||
External input | <NPN output type> ON voltage: 0.4 V DC or less OFF voltage: 5 to 30 V DC, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more <PNP output type> ON voltage: 5 V to +V DC OFF voltage: 0.6 V DC or less, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more |
|||
Operation indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON ) |
|||
Protection | IP40 (IEC) | |||
Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | |||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |||
Voltage withstandability | 500 V AC for one min. between all supply terminals connected together and enclosure | |||
Insulation resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | |||
Vibration resistance | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) | |||
Shock resistance | 100 m/s2 acceleration in X, Y and Z directions three times each | |||
Temperature characteristics | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) | |||
Material | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber |
|||
Connecting method | Connector | |||
Cable length | Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. | |||
Weight | Net weight: 25 g approx. (excluding connector attached cable), Gross weight: 140 g approx. |
|||
Accessories | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set |