Model No. | SC-GU3-04 |
---|---|
Applicable regulations | CE Marking (EMC Directive (Note 1), RoHS Directive), UKCA Marking (EMC Regulations (Note 1), RoHS Regulations) |
Compatible sensor units | Sensor amplifiers (NPN output type) that can connect to the SC‑71 cascading connector unit (optional) |
Number of units connectable | Maximum of 16 units can be connected to one SC-GU3-04 unit (Max. 12 units when FX500 / LS-500 series is connected) |
Supply voltage | 24 V DC +10-15 % Ripple P-P 10 % or less |
Current consumption | 200 mA or less (excluding connected sensor amplifiers) |
Allowable passing current | 2A or less (Note 2) |
Communication method | CC-Link IE Field |
Remote station type | Remote device station |
Transmission line types | Line, star (mixing of line and star types is possible), ring |
Network No. setting | 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or higher result in an error) (Note 3) |
Station No. setting | 1 to 120 (decimal) (0 and 121 or higher result in an error) |
Communication speed | 1 Gbps |
Maximum overall cable distance | 100 m 328.084 ft |
Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (8 to 16 units connected: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed) Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate |
Net weight | 100 g approx. |
Notes:
1) | Ground the shield wire of the Ethernet cable at a higher-level device in order to comply with the EMC Directives / EMC Regulations. This product is not provided with a grounding terminal. For details, refer to the CC-Link IE Field Network Cable Installation Manual published by the CC-Link Partner Association. |
---|---|
2) | Take care that the total consumption current of connected sensor amplifiers and other devices does not exceed the allowable passing current. |
3) | For the Network No. setting of this product, set a value converted to hexadecimal. |
Item | SC-GU3-01 | ||||
---|---|---|---|---|---|
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||||
Number of connectable units | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected) | ||||
Supply voltage | 24 V DC +10-15% Ripple P-P 10 % or less | ||||
Current consumption | 120 mA or less (without connected sensor amplifiers) | ||||
Allowable passing current | Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2) | ||||
Communication method | CC-Link Ver.1.10 | ||||
Number of occupied station | Switchable 1 or 4 station | ||||
Baud rate | 10 Mbps | 5 Mbps | 2.5 Mbps | 625 kbps | 156 kbps |
Total extension length | 100 m 328.084 ft | 150 m 492.126 ft | 200 m 656.168 ft | 600 m 1968.504 ft | 1,200 m 3937.008 ft |
Communication cable | Specified cable (twist pair cable with shield) (Note 3) | ||||
Station No. setting | 1 to 64 (0 and 65 or more: Error) | ||||
Remote station type | Remote device station | ||||
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Material | Enclosure: Polycarbonate | ||||
Weight | Net weight: 80 g approx., Gross weight: 120 g approx. |
Notes:
1) | Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. |
---|---|
2) | In case of supplying power to other devices, be sure to set the current less than allowable passing current. |
3) | Use only a special-use communication cable that is approved by the CC-Link Partner Association. |
Item | SC-GU3-02 | ||||
---|---|---|---|---|---|
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||||
Number of connectable units | Maximum of 16 units per SC-GU3-02 unit (Max. 12 units when FX-500 / LS-500 series are connected) |
||||
Supply voltage | 11 to 25 V DC Ripple P-P 10 % or less | ||||
Current consumption | 80 mA or less (at 24 V) (without connected sensor amplifiers) | ||||
Allowable passing current | Wire-saving connector 2A (Note 1) | ||||
Communication method | DeviceNet compliant | ||||
Baud rate | 500 kbps | 250 kbps | 125 kbps | ||
Total extension length | 100 m 328.084 ft (thick cable) |
250 m 820.21 ft (thick cable) |
500 m 1640.42 ft (thick cable) |
||
100 m 328.084 ft (thin cable) |
100 m 328.084 ft (thin cable) |
100 m 328.084 ft (thin cable) |
|||
Communication cable | Complies with DeviceNet standards (Note 2) | ||||
Address setting | 0 to 63 (64 or more: Error) | ||||
Supported functions | I/O communication (Poll), Explicit message communication | ||||
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew ondensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Material | Enclosure: Polycarbonate | ||||
Weight | Net weight: 75 g approx., Gross weight: 120 g approx. |
Notes:
1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
2) Use a special cable for DeviceNet that complies with the DeviceNet standards.
Item | SC-GU3-03 | ||||
---|---|---|---|---|---|
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) | ||||
Number of connectable units | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected) | ||||
Supply voltage | 24 V DC ±10 % Ripple P-P 10 % or less | ||||
Current consumption | 80 mA or less (at 24 V) (without connected sensor amplifiers) | ||||
Allowable passing current | Wire-saving connector 2 A (Note 1) | ||||
Compliance standard | IEEE802.3u | ||||
Baud rate | 100 Mbps | ||||
Communication cable | Category 5e | ||||
Internodal distance | 100 m 328.084 ft | ||||
Communication ports | RJ45 x 2 | ||||
EtherCAT communication standards |
Process data communication, Mailbox communication | ||||
Ambient temperature |
–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Material | Enclosure: Polycarbonate | ||||
Weight | Net weight: 75 g approx., Gross weight: 120 g approx. |
EtherCAT is a trademark or registered trademark of Beckhoff Automation GmbH.
Notes:
1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
2) ESI file can be downloaded from here.
Item | SC-GU3-EU |
---|---|
CE marking directive compliance | EMC Directive, RoHS Directive |
Number of connectable units | 1 unit for 1 communication unit |
Supply voltage | 11 to 25 V DC Ripple P-P 10 % or less |
Current consumption | 25 mA or less |
Power indicator | Green LED (lights up when the power is ON) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate |
Weight | Net weight: 20 g approx., Gross weight: 20 g approx. |
Item | SC-E1 |
---|---|
Supply voltage | 12 to 24V DC ±10% |
Current consumption | 20 mA or less (with all indicators on) (Note 1) |
Number of signals | 1 input |
Input | Connectable devices: NPN open-collector transistor output type (Input 1) sensor, DC 2-wire output type (Input 2) sensor (Note 2), switches, and other devices Current supply for input device: 100 mA or less Input impedance: 17 kΩ approx. (Input 1) or 3.2 kΩ approx. (Input 2) |
Output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
Power indicator | Green LED (Lights up when the power is ON) |
Input indicator | Green LED (Lights up when input is being received by unit) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85% RH Storage:35 to 85% RH |
Material | Enclosure: Flame-resistant PBT Connector: Polyester |
Weight | Net weight: 15g approx., Gross weight: 40g approx. |
Accessory | Connector (e-CON): 1pc. |
Notes:
1) | Does not include current consumption or input current for connected input devices. |
---|---|
2) | Conditions of connectable DC 2-wire type input device ・Leak current: 1 mA or less (when the power is OFF), Offset voltage: 3 V or less (when the power is ON) ・ Product whose load current range includes 5 to 8 mA |
Item | SC-E81 |
---|---|
Supply voltage | 12 to 24V DC ±10% |
Current consumption | 60 mA or less (with all indicators on) (Note 1) |
Number of signals | 8 inputs (Note 2) |
Input | Connectable devices: NPN transistor / open-collector output type
sensors, switches, and other devices Current supply for input devices: 800 mA or less (total for 8 inputs) Input impedance: Approx. 17 kΩapprox |
Output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
Power indicator | Green LED (lights up when the power is ON) |
Input indicator | 8 green LEDs (light up when input is received from the corresponding channel) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85% RH Storage: 35 to 85% RH |
Material | Enclosure: Polycarbonate Connector: Polyester |
Weight | Net weight: 40g approx., Gross weight: 85g approx. |
Notes:
1) | Does not include current consumption or input current for connected input devices. |
---|---|
2) | Uses eight channels of signaling, regardless of the number of connected input devices. |
Item | SC-E82 |
---|---|
Supply voltage | 5 to 24 V DC ±10% |
Current consumption | 7mA or less |
Number of signals | 8 inputs (Note 1) |
Input | Connectable devices: NPN open-collector transistor output type sensors, switches, and other devices (Note 2) Current supply for input devices: 800 mA or less (total for 8 inputs) |
Power indicator | Green LED (Lights up when the power is ON) |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85% RH Storage: 35 to 85% RH |
Material | Enclosure: Polycarbonate Connector: Polyester |
Weight | Net weight: 40g approx. Gross weight: 85g approx. |
Notes:
1) | Uses eight channels of signaling, regardless of the number of connected input devices. |
---|---|
2) | When using in combination with the SC-MIL, it can use as a commercially available device including a DC 2-wire type sensor or output. Refer to the SC series for the SC-MIL. |
Item | SC-71 |
---|---|
Number of connectable units | Max. 16 units per 1 communication unit |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate, Metal plate: Aluminum |
Weight | Net weight: 10 g approx., Gross weight: 25 g approx. |
Item | Analog voltage input unit | Analog current input unit |
---|---|---|
SC-A01 | SC-A02 | |
Supply voltage | 12 to 24V DC±10%, Ripple P-P 10% or less | |
Current consumption | 25 mA or less (with all indicators on and 24 V applied) (Note 1) | |
Analog input | Voltage: 1 to 5 V DC (input impedance: approx. 200 kΩ) | Current: 4 to 20 mA DC (input impedance: approx. 250 kΩ) |
Communication data (Note 2) |
Analogue ⇔ Communication data ・Communication data: 0 to 4,000 digits (within range of 1 to 5 V) ・Zero point: Within 0 digit ±0.5% F.S. (within the range of 1 to 5V) ・Span: Within 4,000 digits ±0.5% F.S. ・Linearity: Within ±0.5% F.S. |
Analogu ⇔ Communication data ・Communication data: 0 to 4,000 digits (within range of 4 to 20 mA) ・Zero point: Within 0 digit ±0.5% F.S. ・Span: Within 4,000 digits ±0.5% F.S. ・Linearity: Within ±0.5% F.S. |
Input | Connectable devices: NPN open-collector transistor output type Current supply for input devices: 100 mA or less Input impedance: 17 kΩ approx. Operating voltage: On voltage of 17 V or more (between input and +V, 24 V applied) Off voltage of 4 V or less (between input and +V, 24 V applied) |
|
Output | NPN open-collector transistor • Maximum sink current: 50 mA or less (when expanding to 5 units or more, 25 mA) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (with sink current of 50 mA) |
|
Power indicator | Green LED (lights up when the power is ON) | |
Input indicator | Green LED (lights up when input is being received by unit) | |
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
|
Ambient humidity | 35 to 85% RH, Storage: 35 to 85% RH | |
Material | Case: Flame-resistant PBT, Connector: Polyester | |
Weight | Net weight: 15 g approx., Gross weight: 40 g approx. | |
Accessory | Connector (e-CON): 1 |
Note:
1) | Does not include current consumption or input current for connected input devices. |
---|---|
2) | The figure below illustrates the relationship between communication data and input voltage. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)