【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Photoelectric Sensors / Laser Sensors > Leak Detection Sensor EX-F70/EX-F60 > Specifications
Partly Order Discontinued
|
Type | General purpose | Chemical-resistant | |||
---|---|---|---|---|---|
SUS mounting bracket type | PVC mounting bracket type | PFA mounting bracket type | PVC mounting bracket type | ||
Model No. | NPN output | EX-F71 | EX-F72 | EX-F61 | EX-F62 |
PNP output | EX-F71-PN | EX-F72-PN | EX-F61-PN | EX-F62-PN | |
Sensing object | Water, Fluorinert™ (Note 2, 3) | Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note 2, 4, 6) | |||
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||||
Current consumption | 10 mA or less (PNP output type: 15 mA or less) |
15 mA or less | |||
Output | <NPN output type> NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current) 0.4 V or less (at 16 mA sink current) <PNP output type> PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current) 0.4 V or less (at 16 mA source current) |
||||
Utilization category | DC-12 or DC-13 | ||||
Output operation | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | ||||
Short-circuit protection | Incorporated | ||||
Response time | 50 ms or less | ||||
FAULT indicator | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | ||||
NORMAL indicator | Green LED (lights up when the sensor is mounted properly) | ||||
Pollution degree | 3 (Industrial environment) | ||||
Protection | IP67 (IEC) | ||||
Ambient temperature | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ (Note 5) | ||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 1,000 lx or less at the light-receiving face | ||||
Emitting element | Infrared LED (non-modulated) | ||||
Material | Enclosure: Polypropylene | Enclosure: PFA | |||
Cable | 0.1 mm2 3-core PVC cabtyre cable, 2 m 6.562 ft long | 0.1 mm2 3-core PFA cabtyre cable, 3 m 9.843 ft long | |||
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | ||||
Weight | Net weight: 25 g approx. | Net weight: 60 g approx. | |||
Accessories | MS-EX-F7-1 (SUS mounting bracket) (Note 7): 1 pc. |
MS-EX-F7-2, MS-EX-F7-3 (PVC mounting bracket) (Note 7): 1 pc. each for two-point-fixing and adhesive-fixing |
MS-EX-F6-1 (PFA mounting bracket): 1 pc. |
MS-EX-F6-2 (PVC mounting bracket): 1 pc. |
Note 1: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
Note 2: | Highly viscous liquid may not be detected stably. |
Note 3: | Fluorinert is the world wide trademark of 3M. |
Note 4: | The agents mentioned above are examples. For details, please contact our office. |
Note 5: | Liquid being detected should also be kept within the rated ambient temperature range. |
Note 6: | PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. |
Note 7: | The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. |
Designation | Simple wire-saving unit for leak detection sensor | |
---|---|---|
Model No. | EX-FC1 | |
Applicable connector | SL-CP1 | |
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | |
Current consumption | 50 mA or less (for the unit itself), 135 mA or less (including the sensor input current when all outputs of sensors are ON) | |
Output | Relay contact 1a - Switching capacity: 30 V 1 A DC (resistive load) - Min. applied load: 10 mV 10 μA DC - Electrical lifetime: 100,000 switching operations or more (rated load, switching frequency 20 operations/min.) - Mechanical lifetime: 50 million switching operations or more (switching frequency 180 operations/min.) |
|
Utilization category | DC-12 or DC-13 | |
Output operation | The output relay is ON when the input signal from the sensor is ON (Note 2) | |
Response time | 5 ms or less (excluding the response time of the sensor) | |
Input No. | 8 Nos. | |
Indicators | Normal | Green LED x 8 (light up when the sensor is connected to each channel and the connection setting switch is set to ON) |
Error | Red LED x 8 (light up when the leak liquid is detected by a sensor connected to each channel or a sensor is mounted improperly) | |
Output | Orange LED (lights up when the output relay is ON (normal)) | |
Pollution degree | 3 (Industrial environment) | |
Ambient temperature | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
|
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
Material | Enclosure: ABS, Unit mounting base: POM, Terminal part: PBT | |
Cable | 0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long | |
Cable extension | Extension up to total less than 10 m 32.808 ft is possible, with 0.3 mm2, or more, cable. | |
Weight | Net weight: 85 g approx. | |
Accessories | SL-CP1 (Snap male connector): 8 pcs., MS-SL-2 (Unit mounting base): 1 pc. |
Note 1: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
Note 2: | Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)