Enable grip switch SG-C1

Specifications

Designation Enable grip switch
Series SG-C1 series
Applicable
standards
IEC 60947-5-1, EN 60947-5-1, EN 60947-5-8, JIS C 8201-5-1, GS-ET-22, UL 508, CSA C22.2 No.14
  Standards for
use
ISO 12100 / EN ISO 12100, IEC 60204-1 / EN 60204-1, ISO 11161 / EN ISO11161, ISO 10218-1 / EN ISO 10218-1, ANSI/RIA/ISO 10218-1, ANSI/RIA R15.06, ANSI B11.19, ISO 13849-1:2015 / EN ISO 13849-1:2015
Applicable
regulations
CE Marking [Machinery Directive (2006/42/EC), RoSH Directive]
UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoSH Regulations]
Operating
condition
Ambient
temperature
-25 to +60 ℃ -13 to +140 ℉ (No dew condensation or icing allowed)
Storage: -40 to +80 ℃ -40 to +176 ℉
Ambient humidity 45 to 85 % RH
Pollution degree 3 (Inside 2)
Altitude 2,000 m 6,561.68 ft max.
Impulse withstand
voltage (Uimp)
2.5 kV (Momentary pushbutton switch and key selector switch: 1.5 kV)
Rated insulation
voltage (Ui)
250 V (Momentary pushbutton switch and key selector switch: 125 V) /
Models with indicator: 30 V
Thermal current (Ith) 3 A (Emergency stop switch: 5 A)
Rated
operational
voltage (Ue) /
Rated
operational
current (Ie)
(Note)
  Ue
30V 125V 250V
Ie Grip
switch
3 position
enabling switch
(Terminal No.:
NO1-C1, NO2-C2)
AC Resistive load (AC-12) - 1A 0.5A
Inductive load (AC-15) - 0.7A 0.5A
DC Resistive load (DC-12) 1A 0.2A -
Inductive load (DC-13) 0.7A 0.1A -
Push monitor switch
(Terminal No. 31-32)
AC Resistive load (AC-12) - 2.5A 1.5A
Inductive load (AC-15) - 1.5A 0.75A
DC Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive load (DC-13) 2.3A 0.55A 0.27A
Emergency stop
switch
(Terminal No. 1-2, 1-2)
AC Resistive load (AC-12) - 5A 3A
Inductive load (AC-15) - 3A 1.5A
DC Resistive load (DC-12) 2A 0.4A 0.2A
Inductive load (DC-13) 1A 0.22A 0.1A
Momentary pushbutton switch
/ Key selector switch
(Terminal No.
C1-NO1, NC1
C2-NO2, NC2 )
AC Resistive load (AC-12) - 0.5A -
Inductive load (AC-15) - 0.3A -
DC Resistive load (DC-12) 1A 0.2A -
Inductive load (DC-13) 0.7A 0.1A -
Electric shock
protection class
Class II (IEC 61140), 回(double insulated)
(Models with indicator: Class III)
Operating frequency 1,200 operations/hour
B10d 2,000,000
(ISO 13849-1 Annex C Table C.1)
Mechanical
durability
Position 1→2→1: 1,000,000 operations min.
Position 1→2→3→1: 100,000 operations min.
Electrical
durability
100,000 operations min. (Rated operating load)
1,000,000 operations min. (AC / DC 24 V 100 mA)
Shock resistance Malfunction: 150 m/s2, Destruction: 1,000 m/s2
Free fall 1.0 m 3.281 ft 1 time (Based on IEC60068-2-32)
Vibration
resistance
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in
Destruction: 16.7 Hz, half amplitude 1.5 mm 0.059 in
Protection IP66 / IP67 Without additional switch and pilot light
IP65 With additional switch and/or pilot light
Conditional short-circuit
current
50 A (250 V)
Short-circuit
protective device
250 V AC, 10 A Fuse (IEC60127-1)
Direct opening force 60 N min. (Push monitor switch)
Direct opening travel 4.7 mm 0.185 in min. (Push monitor switch)
Actuator Strength
(Entire button is pushed)
500 N min. (Grip switch)
Indicator (Note) Green LED
Rated Operating Voltage: DC 24 V ±10 %
Rated current: 15 mA
Weight SG-C1-21: Approx. 140 g
SG-C1-21-E: Approx. 150 g
SG-C1-21-EG: Approx. 155 g
SG-C1-21-MM: Approx. 155 g
SG-C1-21-EMM: Approx. 165 g
SG-C1-21-EMK: Approx. 170 g

Note: As for the type with pilot light, Ue (contact ratings) of all switches is only less than 30 V DC, and connect all switches to SELV (safety extra low voltage) or PELV (protective extra low voltage) circuit.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)